We compared the effects of bleomycin (BLM) and ionizing radiation on two sublines of murine lymphoma L5178Y (LY): LY-R, radiation resistant and LY-S, radiation sensitive. This radiosensitivity difference is related to the ability to rejoin DNA double strand breaks. LY-S cells were about two times more sensitive to BLM than LY-R, similarly as in the case of sensitivity to X rays. Since there was no difference in the P-glycoprotein-related drug transport system between the sublines, it could be expected that the enhanced sensitivity of LY-S cells to BLM was caused by the DNA repair defect. Growth disturbances in BLM treated cell populations were proportional to the lethal effect and their duration was observed until elimination of dead cells (3-6 days after 50 ěM BLM, 1 h at 37oC). There was no slow growth phase accompanied by normal viability, as previously described for X-irradiated LY-S cells. Initial DNA damage, estimated with the single cell gel electrophoresis method was linearly related to BLM dose in LY-S cells; in LY-R cells - in the low dose range (up to 10 ěM) - there was more damage than in LY-S cells, however, at higher doses the dose - effect curves became identical. The doseeffect relationship for ă rays was linear and identical in both cell sublines. DNA damage distribution in BLM treated cells was much less uniform as compared to that in irradiated cells and indicated the presence of cells with severely damaged DNA, a feature typical for BLM action in vitro.
Źródło:
Nukleonika; 2001, 46, 3; 81-86
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DNA damage in subpopulations of human lymphocytes irradiated with doses in the range of 0-1 Gy of X-radiation
Autorzy:
Wojewódzka, M.
Machaj, E. K.
Goździk, A.
Iwaneńko, T.
Ołdak, T.
Kruszewski, M.
Pojda, Z.
Powiązania:
https://bibliotekanauki.pl/articles/147760.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
alkaline comet assay
biodosimetry
micronucleus test
histone gammaH2AX foci immunofluorescence assay
T lymphocytes
B lymphocytes
ionizing radiation
DNA damage
Opis:
We compared three methods usually applied in biological dosimetry for estimation of radiation-induced DNA damage in human T and B lymphocytes: alkaline comet assay, micronucleus (MN) test and formation of histone gamma-H2AX foci. Human peripheral blood lymphocytes were fractionated using T cells and B cells isolation kits. Cells were irradiated with doses in the range of 0-1 Gy of X-rays. Induction of DNA damage was assessed by the standard alkaline comet assay, MN test and histone gammaH2AX foci immunofluorescence assay. Notwithstanding different end-points measured by the applied methods, all tests revealed a similar induction of DNA damage in B lymphocytes as compared with T lymphocytes. The results indicated that all three tests detect DNA damage with similar sensitivity, the lowest dose being approximately 0.3 Gy. The difference between irradiated and control cells was expressed as the ratio of the value obtained for irradiated cells (1 Gy) to that for control cells. The highest ratio was obtained for formation of gammaH2AX foci and was 6.2 for T and 13.8 for B lymphocytes, whereas those for comet assay and micronucleus test were 3.5; 3.6 and 5.6; 4.8, respectively.
Źródło:
Nukleonika; 2008, 53, 4; 145-149
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment with silver nanoparticles delays repair of X-ray induced DNA damage in HepG2 cells
Autorzy:
Wojewódzka, M.
Lankoff, A.
Dusińska, M.
Brunborg, G.
Czerwińska, J.
Iwaneńko, T.
Stępkowski, T.
Szumiel, I.
Kruszewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/147061.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
silver nanoparticles (Ag NP)
titanium dioxide nanoparticles (TiO2 NP)
DNA break rejoining
alkaline comet assay
ionizing radiation
combined treatment with nanoparticles + X-rays
Opis:
Nanoparticles (NPs) defined as particles having at least one dimension below 100 nm have been applied in the last decade in industry and medicine. Recently, there is an increased concern about the biohazard aspect of the presence of NP in consumer goods and in the environment. Silver NP (Ag NP) cause oxidative stress in mammalian cells in result of generation of reactive oxygen species (ROS). This results in genotoxicity and mutagenicity, disturbed mitochondrial respiration, slowed proliferation and cell death. Using the alkaline comet assay, we examined the effect of combined treatment with Ag NP 20 nm or 200 nm and X-rays (2 Gy) in HepG2 cells. In addition, combined treatment with X-rays and titanium dioxide NP (TiO2 NP) 21 nm was also studied. No effect of NP pre-treatment on X-ray induced initial deoxyribonucleic acid (DNA) damage levels was observed for all three NP. In contrast, Ag NP treatment preceding exposure to X-rays caused a marked decrease in the rate of single strand break rejoining. The effect was particularly strong for Ag NP 20 nm. TiO2 NP pre-treatment had no effect on DNA repair.
Źródło:
Nukleonika; 2011, 56, 1; 29-33
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies