Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "infrared measurements" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Use of Matlab Package for External Local Calibration of IR Camera with Microbolometric FPA Detector
Autorzy:
Kruczek, T.
Adamczyk, W.
Kruczek, G.
Powiązania:
https://bibliotekanauki.pl/articles/114419.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermovision infrared measurements
improvement of accuracy of infrared camera measurements
Opis:
This work presents the method of improving the accuracy of temperature measurement results obtained by means of long-wave infrared camera equipped with focal plane array (FPA) detector. The typical accuracy of infrared cameras specified by their manufacturers amounts to ±2 K or ±2% of the measured value of temperature. Very often a better accuracy of the measurements is required, e.g. during the measurements of human body temperature. To improve the measurement accuracy an external local (in terms of temperature range) correction of obtained results on the basis of comparison measurement results of black body temperature and next with use of MATLAB package has been proposed.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 337-340
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative assessment of heat insulation properties of thermal resistant paints with use of infrared camera
Autorzy:
Kruczek, T.
Szczygieł, I.
Kruczek, G.
Kowalczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/114646.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermovision infrared measurements
thermal resistant paint
Opis:
To reduce heat losses from buildings various methods are used. One of them is applying so called “thermal resistant paints”. These paints can be put in principle on the inner but also on outer surfaces of building external walls. The aforementioned paints are put on a surface in the similar way as other paints in building construction technology and form a thin insulation layer. The acting of this paints consists in causing a noticeable temperature drop within this layer and simultaneously on the wall surface. This work presents the experimental rig, measurement procedures and selected measurement results.
Źródło:
Measurement Automation Monitoring; 2017, 63, 3; 98-101
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the Detector Characteristic on the Result of Sky Temperature Measurement with the Use of Long-Wave Infrared Camera
Autorzy:
Kruczek, T.
Powiązania:
https://bibliotekanauki.pl/articles/114666.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermovision infrared measurements
sky thermal radiation
sky temperature
characteristic of infrared camera detector
Opis:
During the temperature measurements by means of infrared camera the temperature of surrounding elements must be known. In the case of thermovision inspections of the objects exposed to open air space, the surroundings consists of two elements, it is the ground and hypothetical sky surface. The sky temperature measured by long-wave IR camera is of apparent character because it expresses the thermal radiation of the sky within the spectral operational range of this camera i.e. 7.5÷13 μm. The abovementioned spectral range is coincident with so called atmospheric window within which the thermal radiation of the sky is relatively low. The emissivity of atmosphere within this window is low in the central part and high near the limits of the aforementioned range. In relation with the detector characteristic of the IR camera it causes underestimation of the measured sky temperature. This work deals with the analysis of influence of the IR camera detector characteristic on the results of determination of sky temperature and its thermal radiation intensity.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 173-175
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie radiacyjnej temperatury otoczenia przy pomiarach termowizyjnych w otwartej przestrzeni
Determination of radiative ambient temperature during measurements in open air space
Autorzy:
Kruczek, T.
Powiązania:
https://bibliotekanauki.pl/articles/157691.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary termowizyjne
radiacyjna temperatura otoczenia
pomiary w otwartej przestrzeni
termowizyjna diagnostyka rurociągów
infrared measurements
radiative ambient temperature
thermovision diagnosis of pipelines
measurements in open air space
Opis:
Jednym z parametrów wpływającym na wyniki termowizyjnego pomiaru temperatury jest temperatura otoczenia. W przypadku pomiarów w otwar-tej przestrzeni (budynki, rurociągi i in.) otoczenie składa się z dwóch elementów: nieboskłonu i gruntu. Elementy te mają na ogół różne tempe-ratury. W pracy przedstawiono sposób pomiaru temperatury nieboskłonu, a następnie metodę wyznaczania temperatury izotermicznego otoczenia badanego obiektu zastępującego układ dwóch elementów otoczenia o różnych temperaturach: podłoża i nieboskłonu. W oparciu o opracowany model przeprowadzono obliczenia numeryczne, a wyniki przedstawiono na wykresach. Umożliwiają one określenie zastępczej temperatury otoczenia przy pomiarach termowizyjnych w otwartej przestrzeni.
During the thermovision inspection a few important parameters influence the results of temperature measurements. Among these parameters the emissivity of surface under consideration as well as the temperature of the ambient elements can be specified. In the case of overhead heat pipelines, convective and radiative heat transfers take place between thermal pipeline and its surroundings. Generally, the ambient of the external overhead pipeline consists of two surfaces: hypothetical sky and ground surface, Figs. 1, 2a. The method concerning the determination of apparent temperature of the hypothetical sky surface has been developed. The method is based on radiosity balances formulated for each considered element [1]. In this method the radiation of atmosphere towards the ground surface is substituted by the radiation of the assumed artificial surface, Fig. 1. As a result, the ambient system of two surfaces having different temperatures is obtained, Fig. 2a. Next, this system is converted into one-surface system and a method of expressing the radiation influence of these elements on the measurement result by means of one ambient temperature is developed. The aforementioned temperature is called an equivalent ambient temperature and can be calculated on the basis of equation (22). Numerical calculations have been carried out for the assumed typical data and results are shown in diagrams of Figs. 3, 4, 5. The diagrams allow estimating properly the representative ambient temperature in the case of infrared measurements of temperature in open air space.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 882-885
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie kamery termowizyjnej LW w pomiarze cieplnego promieniowania nieboskłonu
Use of LW infrared camera for measurement of sky thermal radiation
Autorzy:
Kruczek, T.
Powiązania:
https://bibliotekanauki.pl/articles/151610.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary termowizyjne
promieniowanie cieplne nieboskłonu
radiacyjna temperatura nieboskłonu
badania termowizyjne rurociągów napowietrznych
thermovision infrared measurements
sky thermal radiation
sky radiative temperature
thermovision inspection of overhead pipelines
Opis:
Znajomość cieplnej emisji nieboskłonu jest niezbędna w obliczeniach radiacyjnej wymiany ciepła pomiędzy obiektami w otwartej przestrzeni i otoczeniem. Praca dotyczy zastosowania wyniku pomiaru temperatury nieboskłonu za pomocą kamery termowizyjnej do określenia gęstości cieplnego promieniowania nieboskłonu. Temperatura nieboskłonu jest temperaturą pozorną, wynikającą z intensywności jego promieniowania. Artykuł dotyczy problemu pomiaru tej temperatury i zawiera propozycję jego rozwiązania.
The work deals with measurement of the apparent temperature of the sky with use of a long-wave (LW) infrared camera and determination of the sky thermal radiation intensity. Convective and radiative heat transfer takes place between a heat pipeline and the surrounding on the external pipeline shell. In the case of a low temperature of the sky, the radiation heat exchange is very intensive and the temperature of the top part of the horizontal pipeline is much lower than the bottom part and can drop below the atmospheric air temperature. The aforementioned phenomenon causes difficulties during evaluation of the quality of the pipeline thermal insulation and determination of the pipeline heat losses. The occurrence of this phenomenon strongly depends on the intensity of thermal radiation of the sky. The paper contains a description of the method for determination of the sky thermal radiation intensity on the basis of sky temperature measurement with the use of an LW infrared camera. To verify the developed method, the results obtained with the use of the LW infrared camera and measurement results obtained by means of a pyrgeometer were compared. The result of this comparison is quite satisfactory.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 905-908
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane aspekty termowizyjnych pomiarów temperatury tarczy podczas eksperymentalnych badań hamulców tarczowych
Some aspects of IR temperature measurements of a disc during experimental investigations of disc brakes
Autorzy:
Kruczek, T.
Kowal, L.
Turewicz, K.
Ścieszka, S. F.
Żołnierz, M.
Powiązania:
https://bibliotekanauki.pl/articles/155564.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hamulec tarczowy
temperatura tarczy
pomiary termowizyjne
emisyjność tarczy
disc brake
disc temperature
infrared camera measurements
disc emissivity coefficient
Opis:
Przedstawiono wybrane wyniki badań hamulca tarczowego na stanowisku laboratoryjnym. W trakcie doświadczeń mierzone były główne parametry procesu hamowania oraz rozkłady temperatury w klocku i na powierzchni tarczy hamulcowej za pomocą kamery termowizyjnej. Zebrane dane pomiarowe stanowią materiał do weryfikacji modeli matematycznych przy numerycznej symulacji działania tego typu hamulców. Głównym tematem tej pracy jest analiza zmian współczynnika emisyjności powierzchni tarczy w warunkach prowadzenia eksperymentów. Znajomość stwierdzonych prawidłowości jest przydatna przy planowaniu i prowadzeniu tego typu badań.
Selected results of testing a disc brake on the laboratory stand, Fig. 1, are presented. There were measured the parameters of braking mechanics as well as the temperature distribution in a brake block and on the disc surface. The temperature distribution was determined with use of an infrared camera. The obtained measurement data were used for verification of the mathematical models for numerical simulations of brakes operation. The problems in determination of the disc surface emissivity coefficient and the character of its changeability during experiments at different braking parameters, Figs. 58, were the objectives of the project. The measurements of the emissivity coefficient on the entire disc surface were taken repeatedly, Figs. 2, 3. A correlation between the disc emissivity coefficient and the mechanical parameters of braking was found. Despite the fact that these correlations are qualitative rather than quantitative, they are interesting from the point of view of identification of the braking process as well as of planning such experiments. During the measurements, some interesting practical experience in the field of infrared measurements of temperature of the surface of not high emissivity coefficient was gained. In the project an isothermal protective screen was applied to normalize the radiation impact of the environment on the measurements, Figs 1, 4.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 969-972
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies