Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "scanning systems" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Equilibrium and non-equilibrium freezing of water in clay-water systems
Autorzy:
Kozłowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/396601.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
system glina-woda
kalorymetr skaningowy
zamarzanie
temperatura krystalizacji
clay-water systems
scanning calorimetry
freezing
temperature of spontaneous nucleation
Opis:
The temperature of spontaneous nucleation Tsn and the equilibrium freezing point Tf were determined for six monomineral, homoionic clayey soils by use of the Differential Scanning Calorimetry (DSC) technique. The temperature of spontaneous nucleation Tsn was determined on the cooling run, as the initial temperature of the observed exothermic peak. The temperature of equilibrium freezing (or melting) Tf was comprehended as the initial temperature of the last non-zero thermal impulse in the diagram of real thermal impulses distribution q(T) obtained on warming.The supercooling was calculated as the difference between Tf and Tsn. The obtained results testify the strong dependency of the equilibrium freezing point Tf on the water content w. It has been proved that Tf can be expressed as a power function of water content wand the limit of plasticity with a high correlation coefficient (R=0.933) showing a good fit to the experimental data. In contrary, a scatter of results was observed for Tsn and [...], which could be related to the effect of factors other than the water content. The diagrams of the supercooling vs. the water content suggest a relationship with an extreme. The critical water content, Wcr at which the supercooling reaches a maximum, was found by use of a quadratic empirical model. For all the clay-water systems, the criitical water content Wcr occurs between the plastic limit Wp and the liquid limit W_L.'
Źródło:
Civil and Environmental Engineering Reports; 2009, 3; 77-91
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies