Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kowalski, B" wg kryterium: Autor


Tytuł:
Enhanced External Counterpulsation in Patients with Advanced Ischemic Cardiomyopathy
Autorzy:
Przywara-Chowaniec, B.
Gawlikowski, M.
Kuczaj, A.
Bachorz, M.
Czechowski, P.
Kowalski, P.
Geodecki, M.
Kawecki, D.
Barańska, K.
Paluch, M.
Pluszczyk, M.
Opara, M.
Puzio, A.
Nowalany-Kozielska, E.
Powiązania:
https://bibliotekanauki.pl/articles/1418031.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
47.63.Ec
82.60.Fa
Opis:
A significant increase in the number of patients with heart failure of varied etiology has been observed in the recent years. Apart from pharmacological and surgical therapies, new, non-invasive assistance methods of cardiovascular system are still sought. One of them is external counterpulsation. Within this study, effectiveness of such a form of therapy has been examined in a group of 10 patients with an ischemic left ventricular systolic dysfunction. It has been shown that external counterpulsation has a beneficial influence onto the result of a six-minute walk test and causes a slight decrease in the creatinine concentration in the patients undergoing the tests.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 866-869
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja systemu rozpowszechniania i wymiany wiedzy o georeferencyjnej bazie danych
Towards a system for disseminating and exchanging knowledge about georeference database
Autorzy:
Berus, T.
Bielawski, B.
Kowalski, P.
Olszewski, R.
Pillich-Kolipińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/346424.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Informacji Przestrzennej
Tematy:
baza danych georeferencyjnych
technologia WIKI
geoportal
georeference database
WIKI technology
Opis:
Efektywne wdrażanie infrastruktury informacji przestrzennej w Polsce, zwłaszcza zaś szerokie wykorzystanie danych przestrzennych zgromadzonych w urzędowej bazie danych referencyjnych, wymaga nie tylko ukończenia projektu BDOT, lecz także upowszechnienia wiedzy na temat struktury bazy danych topograficznych, jej aktualności, poziomu dokładności geometrycznej i możliwości jej wykorzystania w wielu dziedzinach. Zdaniem autorów, dla upowszechnienia wiedzy o bazie danych georeferencyjnych korzystne byłoby zastosowanie systemu opartego na technologii WIKI. W ramach realizowanego projektu badawczego autorzy opracowują zatem wiki-serwis internetowy. Serwis ten będzie umożliwiał nie tylko formułowanie reguł bazy wiedzy użytkownikom posiadającym status eksperta, ale przede wszystkim będzie pełnił rolę informacyjną w odniesieniu do systemu danych referencyjnych kraju. Integralną częścią tego systemu będzie baza wiedzy o rozwiązaniach zastosowanych przy tworzeniu baz TBD i BDOT, wypracowanych metodach ich wykorzystania oraz perspektyw rozwoju. Baza wiedzy zostanie opublikowana w postaci szeregu artykułów. Zastosowanie technologii WIKI pozwoli na wykorzystanie wbudowanych narzędzi do tworzenia odsyłaczy pomiędzy artykułami, co usprawni proces ich publikowania oraz wykorzystania przez użytkowników zewnętrznych. Zróżnicowanie uprawnień dostępu zapewni rzetelność informacji zamieszczanych w serwisie. Informacje te stanowić będą podstawowy kanał rozpowszechniania wiedzy, zostaną także uzupełnione o opis innych baz danych referencyjnych, historii ich tworzenia oraz definicji z nimi związanych. Opisane zostaną również aspekty technologiczne tworzenia wielorozdzielczej bazy danych referencyjnych, wraz z przykładami wizualizacji kartograficznych. Użytkownicy systemu będą mogli zapoznać się z opracowaną metodyką analiz i wizualizacji danych referencyjnych. Z drugiej strony portal będzie miejscem wymiany uwag i zadawania pytań przez użytkowników, co pozwoli na modyfikację i udoskonalenie stosowanych metod i technologii, a także prowadzenie badań nad poprawnością przekazu kartograficznego. Autorzy żywią nadzieję, iż portal ten stanie się źródłem wiedzy dla użytkowników i będzie promował nowoczesne rozwiązania geoinformacyjne wśród odbiorców na różnych stopniach edukacji.
Effective implementation of the spatial information infrastructure in Poland, especially extensive use of spatial data collected in the official reference database, requires not only completing the BDOT project, but also disseminating knowledge about the topographic database’s structure, its relevance, geometrical accuracy and the possibility of using it in many areas. According to the authors, using a system based on WIKI technology would be beneficial for spreading knowledge about georeference database. A research project, still being conducted by the authors, among its many aspects involves the WIKI-website development. This website will not only provide users with expert status to formulate the rules for knowledge base, but also will act as an information system of the Poland’s official reference database. The knowledge base of solutions used for creating, using and developing BDOT and TBD databases will be an integral part of this system. It will be published as a series of articles. Using WIKI technology allows using built-in tools for creating links between articles, which will streamline the process of publishing as well as using them by external users. Access rights diversification will ensure the accuracy of information provided on the website. This information will become a key channel of knowledge dissemination and will also be supplemented by a description of other reference databases, their history and definitions associated with them. The technological aspects of creating multiresolution reference database, along with examples of cartographic visualization will be described as well. The users of the system will be able to see the developed methodology of analysis and visualization of reference data. On the other hand, the portal will hopefully become a place for exchanging comments and asking questions, which will allow experts to refine and modify the methods and technologies used in the mentioned databases development, as well as to conduct research on correctness of cartographic communication. The authors hope that the portal will become a popular information source for users and will promote innovative geo-information solutions among the users at different levels of education.
Źródło:
Roczniki Geomatyki; 2012, 10, 3; 27-36
1731-5522
2449-8963
Pojawia się w:
Roczniki Geomatyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechatronic rehabilitation devices to re-education of the knee joint muscles
Autorzy:
Nowak, G.
Kubik, B.
Juszyński, Ł.
Wochnik, D
Sobiech, M.
Kowalski, P.
Michnik, A.
Powiązania:
https://bibliotekanauki.pl/articles/333819.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
rehabilitation
knee joint
thermotherapy
traction
rehabilitacja
staw kolanowy
termoterapia
trakcja
Opis:
Article is devoted to innovative, mechatronic devices. These devices enable the rapid and effective knee joint rehabilitation. The following machines are computer-assisted. The devices have been designed and constructed by the Institute of Medical Technology and Equipment ITAM in Zabrze, after consultation with specialists in the field of rehabilitation of the Silesian Rehabilitation Centre ”REPTY”.
Źródło:
Journal of Medical Informatics & Technologies; 2013, 22; 271-276
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deposition of Chitosan Layers on NiTi Shape Memory Alloy
Osadzanie warstw chitozanu na powierzchni stopu NiTi wykazującego pamięć kształtu
Autorzy:
Kowalski, P.
Łosiewicz, B.
Goryczka, T.
Powiązania:
https://bibliotekanauki.pl/articles/353236.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surface modification
chitosan
NiTi
shape memory
modyfikacja powierzchni
chitozan
pamięć kształtu
Opis:
The NiTi shape memory alloys have been known from their application in medicine for implants as well as parts of medical devices. However, nickel belongs to the family of elements, which are toxic. Apart from the fact that nickel ions are bonded with titanium into intermetallic phase, their presence may cause allergy. In order to protect human body against release of nickel ions a surface of NiTi alloy can be modified with use of titanium nitrides, oxides or diamond-like layers. On the one hand the layers can play protective role but on the other hand they may influence shape memory behavior. Too stiff or too brittle layer can lead to limiting or completely blocking of the shape recovery. It was the reason to find more elastic covers for NiTi surface protection. This feature is characteristic for polymers, especially, biocompatible ones, which originate in nature. In the reported paper, the chitosan was applied as a deposited layer on surface of the NiTi shape memory alloy. Due to the fact that nature of shape memory effect is sensitive to thermo and/or mechanical treatments, the chitosan layer was deposited with use of electrophoresis carried out at room temperature. Various deposition parameters were checked and optimized. In result of that thin chitosan layer (0.45µm) was received on the NiTi alloy surface. The obtained layers were characterized by means of chemical and phase composition, as well as surface quality. It was found that smooth, elastic surface without cracks and/or inclusions can be produced applying 10V and relatively short deposition time - 30 seconds.
Stopy NiTi wykazujące pamięć kształtu znane są ze swych zastosowań w medycynie na implanty oraz części urządzeń medycznych. Jednakże, nikiel należy do rodziny pierwiastków o toksycznym działaniu. Oprócz faktu, że jony niklu są związane z tytanem w fazę międzymetaliczną, ich obecność może powodować alergię. W celu ochrony organizmu przed uwalnianymi jonami niklu powierzchnia stopu NiTi może być modyfikowana z wykorzystaniem azotków tytanu, tlenków lub warstw dia-mentopodobnych. Z jednej strony warstwy mogą odgrywać rolę ochronną, ale z drugiej strony mogą wpłynąć na zachowanie pamięci kształtu. Zbyt sztywna lub zbyt krucha warstwa może prowadzić do ograniczenia lub całkowitego zablokowania odzysku kształtu. Był to powód, aby znaleźć bardziej elastyczne pokrycia zabezpieczające powierzchnię NiTi. Ta cecha jest charakterystyczna dla polimerów, zwłaszcza biokompatybilnych polimerów pochodzenia naturalnego. W omawianym artykule zastosowano chitozan jako osadzaną warstwę na powierzchni stopu NiTi, wykazującego pamięć kształtu. Ze względu na fakt, że natura efektu pamięci kształtu jest wrażliwa termicznie oraz na obróbkę mechaniczną, warstwa chitozanu została osadzona z wykorzystaniem elektroforezy przeprowadzonej w temperaturze pokojowej. Sprawdzano i optymalizowano różne parametry osadzania. W rezultacie otrzymano cienką warstwę chitozanu (0,45µm) na powierzchni stopu NiTi. Uzyskane warstwy scharakteryzowano pod względem składu chemicznego i fazowego jak również jakości powierzchni. Stwierdzono, że gładka, elastyczna powierzchnia, bez pęknięć i/lub wtrąceń może być uzyskana stosując napięcie 10V i stosunkowo krótki czas osadzania - 30 sekund.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 1; 171-176
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
Autorzy:
Wieczorek, A.
Zgardzińska, B.
Jasińska, B.
Gorgol, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Silarski, A.
Strzelecki, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/147132.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
free volume
positron annihilation
polystyrene
positronium
scintillator
Opis:
The polystyrene doped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260, 283, and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 777-781
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Processing optimization with parallel computing for the J-PET scanner
Autorzy:
Krzemień, W.
Bała, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Stola, K.
Strzelecki, A.
Trybek, D.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/148285.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
data aquisition system (DAQ)
parallel computing
TOF-PET
Opis:
The Jagiellonian Positron Emission Tomograph (J-PET) collaboration is developing a prototype time of flight (TOF)-positron emission tomograph (PET) detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast fi eld programmable gate array (FPGA)-based front-end electronics and the data acquisition system, as well as low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in the case of a large acceptance detector that works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 745-748
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Autorzy:
Sharma, N. G.
Silarski, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/146937.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
J-PET detector
Mahalanobis distance
time resolution
threshold levels
Opis:
The J-PET detector being developed at the Jagiellonian University is a positron emission tomograph composed of the long strips of polymer scintillators. At the same time, it is a detector system that will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit time and hit position of the gamma quantum. In order to take advantage of this fact, a dedicated sampling front-end electronics that enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity, we use the Mahalanobis distance. The achievable position and time resolution depend on the number and values of the threshold levels at which the signal is sampled. A reconstruction method as well as preliminary results are presented and discussed.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 765-769
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
Autorzy:
Kamińska, D.
Gajos, A.
Czerwiński, E.
Bednarski, T.
Białas, P.
Gorgol, M.
Jasińska, B.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/147408.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
discrete symmetries
J-PET
ortho-positronium
Opis:
In this paper, we present prospects for using the Jagiellonian positron emission tomograph (J-PET) detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the standard model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10−3. The J-PET detector allows to determine those values with better precision, thanks to the unique time and angular resolution combined with a high geometrical acceptance. Achieving the aforementioned is possible because of the application of polymer scintillators instead of crystals as detectors of annihilation quanta.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 729-732
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies of unicellular microorganisms Saccharomyces cerevisiae by means of positron annihilation lifetime spectroscopy
Autorzy:
Kubicz, E.
Jasińska, B.
Zgardzińska, B.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rajfur, Z.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/147902.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
environmental scanning electron microscopy (ESEM)
free volume
inverted microscopy
positron annihilation
positronium
yeasts
Opis:
Results of positron annihilation lifetime spectroscopy (PALS) and microscopic studies on simple microorganisms, brewing yeasts, are presented. Lifetime of ortho-positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer-lived component) for lyophilized and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water – the main component of the cell – affects PALS parameters, thus lifetime of o-Ps were found to change from 1.2 to 1.4 ns (shorter-lived component) for the dried yeasts. The time sufficient to hydrate the cells was found below 10 hours. In the presence of liquid water, an indication of reorganization of yeast in the molecular scale was observed. Microscopic images of the lyophilized, dried, and wet yeasts with best possible resolution were obtained using inverted microscopy (IM) and environmental scanning electron microscopy (ESEM) methods. As a result, visible changes to the surface of the cell me mbrane were observed in ESEM images.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 749-753
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of wireless medical systems for recording biomedical parameters, created at ITAM in recent years, in light of global achievements in the field
Autorzy:
Szuster, B.
Szczurek, Z.
Kowalski, P.
Kubik, B.
Michnik, A.
Wiśniowski, R.
Świda, K.
Wołoszyn, J.
Powiązania:
https://bibliotekanauki.pl/articles/398130.pdf
Data publikacji:
2016
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
body sensor network
wireless medicine
Hexoskin
Equivital
Zephyr
Quariocor
BioSip
WBAN
wireless body area network
Monitel
sieć sensorowa na powierzchni ciała
medycyna bezprzewodowa
bezprzewodowa sieć obszaru ciała
Opis:
Progress in technology and the demand for systems used for psychophysiological measurements, which record several synchronous parameter / signal types at a time, have a significant impact on the increasing number of innovative solutions available in the market. This article focuses on the design and engineering path of the created systems with special emphasis on the latest solutions, developed at the Institute of Medical Technology and Equipment (ITAM) in Zabrze. Competitive systems and other systems are also referred to by way of a comparative analysis, both in terms of their benefits and drawbacks. The overview shows that the new system may become a competitive solution for the already existing options and that it is characterized by a number of properties that make it unique.
Źródło:
International Journal of Microelectronics and Computer Science; 2016, 7, 3; 79-86
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected hardware solutions used in the process of monitoring bioparameters
Autorzy:
Michnik, A.
Szczurek, Z.
Szuster, B.
Kubik, B.
Kowalski, P.
Powiązania:
https://bibliotekanauki.pl/articles/397967.pdf
Data publikacji:
2016
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
body area networks
telemedicine
ultra-low power
inductive charging
ECG
GSR
Bluetooth Low Energy
BioSip
sieć sensorowa na powierzchni ciała
telemedycyna
ultra low power
ładowanie indukcyjne
EKG
Opis:
The paper presents the idea behind the implementation of a system designed to monitor biomedical parameters and the subject's behaviour on the basis of the architecture of measurement modules located on the body. The system was developed as a result of market launch of new generations of electronic devices combining high functionality, small size and low power consumption. The paper presents the elements of the system called BioSip, along with hardware solutions selected for the objectives to be accomplished, i.e. providing communication between system elements that would be efficient and resistant to artefacts, extending the time of operation for battery power supply, as well as ensuring a satisfactory level of reliability and ease of use.
Źródło:
International Journal of Microelectronics and Computer Science; 2016, 7, 1; 26-32
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure of chitosan-ZnO layers electrophoretically deposited on NiTi shape memory alloy
Autorzy:
Goryczka, T.
Kokoszka, A.
Kowalski, P.
Łosiewicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/1112222.pdf
Data publikacji:
2016-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.10.Nz
61.66.Dk
68.37.Hk
81.30.Kf
87.68.+z
Opis:
The surface of NiTi shape memory was modified by deposition of chitosan-ZnO thin film. The electrodeposition process was carried out at room temperature at voltage-time conditions: 10 V/30 s, 10 V/300 s, 20 V/30 s, or 20 V/300 s. Structure of the obtained coatings was studied by means of grazing incidence beam X-ray diffraction. Distribution of the zinc oxide particles in the chitosan matrix was observed with use of scanning electron microscopy. It was found that depending on the electrodeposition parameters, the structure of the obtained chitosan-ZnO coatings varies from amorphous to coarse-grained.
Źródło:
Acta Physica Polonica A; 2016, 130, 4; 1056-1058
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transmission of biomedical data from BIOSIP modules in a wireless personal area network with synchronous measurements, and the future use in the internet of things
Autorzy:
Szuster, B.
Szczurek, Z.
Kowalski, P.
Kubik, B.
Michnik, A.
Wiśniowski, R.
Świda, K.
Powiązania:
https://bibliotekanauki.pl/articles/397939.pdf
Data publikacji:
2016
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
body sensor network
wireless medicine
low power
personal area network
Bluetooth Smart
ANT
BioSip
WPAN
Wireless Personal Area Network
Body Area Networks
internet of things (IoT)
IoT
IPv6
Internet Protocol version 6
sieć sensorowa na powierzchni ciała
medycyna bezprzewodowa
sieć osobista
Internet rzeczy
protokół internetowy w wersji 6
Opis:
The paper aims to present the organizational concept of the wireless personal area network (WPAN network) transmitting biomedical data, used in the BioSip system. The network transmits data from recording modules arranged on the subject's body to a collective node (data integrator). At the same time, all the necessary properties are maintained, i.e. low power consumption of the modules, increased resistance of the network to artefacts, the required transmission speed and signal delays. The options to synchronize measurements in various modules have also been presented, along with the resulting benefits. The wireless personal area network of BioSip modules may be based on various communication protocols, such as Bluetooth Smart or ANT. The BioSip network builds on its own protocol based on transmission mechanisms by Nordic. The software of BioSip modules may be adapted for operation in the Internet of Things through network protocol layers made available by Nordic.
Źródło:
International Journal of Microelectronics and Computer Science; 2016, 7, 1; 33-40
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Method to Produce Linearly Polarized Positrons and Positronium Atoms with the J-PET Detector
Autorzy:
Mohammed, Muhsin
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, ---
Skurzok, M.
Silarski, M.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1030045.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.75.Fr
41.75.Ht
77.22.Ej
36.10.Dr
85.75.Mm
87.57.uk
Opis:
A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1486-1489
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Procedure of the Positronium Lifetime Spectra for the J-PET Detector
Autorzy:
Dulski, K.
Zgardzińska, B.
Białas, P.
Curceanu, C.
Czerwiński, E.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, Shivani
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033298.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.05.Kf
13.30.Ce
14.60.-z
78.47.-p
Opis:
Positron annihilation lifetime spectroscopy has shown to be a powerful tool to study the nanostructures of porous materials. Positron emission tomograph is a device allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the Jagiellonian PET will allow positron annihilation lifetime spectroscopy in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the Jagiellonian PET software. We compare its performance with the standard program LT 9.0 by using positron annihilation lifetime spectroscopy data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1637-1640
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies