Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "etanol" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Ethanol pool fire on a one-meter test tray – validation of CFD results
Autorzy:
Cherbański, Robert
Rudniak, Leszek
Machniewski, Piotr
Molga, Eugeniusz
Tępiński, Jarosław
Klapsa, Wojciech
Lesiak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2173418.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ogień w basenie
etanol
CFD
SBES
pool fire
ethanol
large-scale
Opis:
The ethanol fire hazards will become more frequent due to the new established targets for the consumption of renewable energy sources. With this in mind, this paper aims to widen the current knowledge on CFD modelling of such a fire. As previous works rely heavily on the data of small pool fire diameters (below 1 m), this research deals with ethanol pool fire on a one-meter test tray, using our own experimental data. A mathematical model was developed and solved using a commercial CFD package (ANSYS Fluent). A new hybrid RANS-LES (SBES) model was employed to calculate turbulent stresses. Generally, the simulation results showed a good fit with the experimental results for flame temperatures at different elevations. In particular, a minor discrepancy was only observed for the top thermocouple (1.9 m above the tray). The flame heights computed with the CFD model were on average higher than the experimental one. Good agreement was observed for the radiative fraction and the axial temperature profile on the plume centreline. The latter showed an almost perfect fit between the temperature profiles obtained from CFD simulations and those calculated from the plume law for temperature.
Źródło:
Chemical and Process Engineering; 2022, 43, 1; 23--44
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of Large Scale Pool Fire of Technical Ethanol
Badania pożaru powierzchniowego etanolu technicznego w dużej skali
Autorzy:
Tępiński, Jarosław
Klapsa, Wojciech
Cygańczuk, Krzysztof
Lesiak, Piotr
Lewak, Michał Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2060712.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
pool fire
field tests
technical ethanol
temperature
thermal radiation
pożar powierzchniowy
badania poligonowe
etanol techniczny
temperatura
promieniowanie cieplne
Opis:
Aim: The aim of this article is to determine the characteristics of a pool fire, including the temperatures and thermal radiation densities caused by it. Mappings of pool fires occurring in actual emergency events were conducted by performing large-scale polygon tests. Project and methods: Experimental study of pool fire of technical ethanol was carried out on a specially built test stand in the training area of the Training Centre in Pionki of the Regional Headquarters of the State Fire Service in Warsaw. The pool fire test stand consisted of a test tray, with a test chamber with the diameter of 300 cm, founded on a reinforced concrete slab. Using a developed measurement system with data acquisition that included measurement sensors mounted at defined locations relative to the fire, temperatures and thermal radiation densities were measured at various distances/locations relative to the fire. Metrological data such as air temperature, atmospheric pressure, humidity, wind direction and speed were monitored and recorded using the weather station. The height of the fire flame was measured by comparing it to racks set up nearby with marked scales of specific lengths. Results: A polygon stand that was built to study pool fires, equipped with a temperature and thermal radiation density measuring system with measuring sensors distributed in defined locations, is discussed. A study of a pool fire resulting from the combustion of dehydrated, fully contaminated ethanol was conducted. The study measured temperatures, thermal radiation densities, and flame heights. The average and maximum values of temperatures and thermal radiation densities during the steady-state combustion stage (i.e., phase II of the fire) were determined. Conclusions: Based on the presented results of temperature and thermal radiation density measurements at various distances/locations relative to the pool fire site, there was a significant effect of wind direction and speed on these values. Higher temperature and heat radiation density were recorded at the sensors on the leeward side than on the windward side. As the wind speed decreased, there was an increase in the temperature values recorded on the thermocouples located above the centre of the bottom of the tray test chamber due to the flame, which, when not blown away, was allowed to rise vertically upward and fully sweep the temperature sensors.
Cel: Celem artykułu jest określenie charakterystyki pożaru powierzchniowego, w tym temperatur i gęstości promieniowań cieplnych przez niego wywoływanych. Odwzorowania pożarów powierzchniowych mających miejsce w rzeczywistych zdarzeniach awaryjnych przeprowadzono poprzez wykonanie poligonowych badań w dużej skali. Projekt i metody: Badanie doświadczalne pożaru powierzchniowego etanolu technicznego zrealizowano na specjalnie do tego celu zbudowanym stanowisku badawczym na terenie poligonu Ośrodka Szkolenia w Pionkach Komendy Wojewódzkiej Państwowej Straży Pożarnej w Warszawie. W skład stanowiska do badania pożarów powierzchniowych wchodziła taca badawcza, o średnicy komory badawczej wynoszącej 300 cm, posadowiona na płycie żelbetowej. Przy pomocy opracowanego układu pomiarowego z akwizycją danych, w skład którego wchodziły czujniki pomiarowe zamontowane w zdefiniowanych lokalizacjach względem pożaru, dokonano pomiarów temperatur i gęstości promieniowań cieplnych w różnych odległościach/lokalizacjach względem miejsca pożaru. Za pomocą stacji pogodowej monitorowano i rejestrowano dane metrologiczne, takie jak temperatura powietrza, ciśnienie atmosferyczne, wilgotność, kierunek i prędkość wiatru. Pomiaru wysokości płomienia pożaru dokonano przez jego porównanie z ustawionymi w pobliżu stojakami z zaznaczonymi podziałkami o określonych długościach. Wyniki: Omówiono poligonowe stanowisko, które zostało zbudowane do badania pożarów powierzchniowych, wyposażone w układ pomiarowy temperatur i gęstości promieniowań cieplnych z czujnikami pomiarowymi rozmieszczonymi w zdefiniowanych lokalizacjach. Przeprowadzono badania pożaru powierzchniowego powstałego w wyniku spalania etanolu odwodnionego, całkowicie skażonego. W ramach badań dokonano pomiarów temperatur, gęstości promieniowań cieplnych oraz wysokości płomienia. Wyznaczono średnie i maksymalne wartości temperatur i gęstości promieniowań cieplnych w etapie ustalonego spalania (tzn. II faza pożaru). Wnioski: Na podstawie przedstawionych wyników pomiarów temperatur i gęstości promieniowań cieplnych w różnych odległościach/lokalizacjach względem miejsca pożaru powierzchniowego, odnotowano znaczący wpływ kierunku i prędkości wiatru na te wartości. Wyższą temperaturę i gęstość promieniowań cieplnych rejestrowano na czujnikach po stronie zawietrznej niż po stronie nawietrznej. Na skutek spadku prędkości wiatru następował wzrost wartości temperatur rejestrowanych na termoparach umieszczonych nad środkiem dna komory badawczej tacy, co było spowodowane przez płomień, który niezdmuchiwany, mógł unosić się pionowo do góry i w pełni omiatać czujniki temperatury.
Źródło:
Safety and Fire Technology; 2022, 59, 1; 96--109
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies