- Tytuł:
- Properties of Pure Ti Implants Fabricated by Additive Manufacturing
- Autorzy:
-
Kim, Dong-Jin
Kim, Hyung-Giun
Kim, Ji-Sun
Song, Kuk-Hyun - Powiązania:
- https://bibliotekanauki.pl/articles/354362.pdf
- Data publikacji:
- 2019
- Wydawca:
- Polska Akademia Nauk. Czytelnia Czasopism PAN
- Tematy:
-
pure Ti
selected laser melting
heat input
microstructure
mechanical property - Opis:
- This study was carried out to evaluate the aspect of microstructure and mechanical property development on additive manufactured pure Ti at elevated heat-input. For this work, pure Ti powder (commercial purity, grade 1) was selected, and selective laser melting was conducted from 0.5 to 1.4 J/mm. As a result, increase in heat-input led to the significant grain growth form 4 μm to 12 μm, accompanying with the change of grain shape, correctly widmanstätten structured grains. In addition, Vickers microhardness was notably increased from 228 Hv to 358 Hv in accordance with elevated heat-input, which was attributed to the increased concentration of oxygen and nitrogen mainly occurred during selected laser melting process.
- Źródło:
-
Archives of Metallurgy and Materials; 2019, 64, 3; 959-962
1733-3490 - Pojawia się w:
- Archives of Metallurgy and Materials
- Dostawca treści:
- Biblioteka Nauki