Fault detection and isolation for power electronic systems featuring parameter uncertainty
Detekcja i lokalizacja uszkodzeń układu energoelektronicznego zawierającego niedokładnie określone parametry
Autorzy:
Juszczyk, W.
Kich, Z.R.
Zając, M.
Powiązania:
https://bibliotekanauki.pl/articles/159700.pdf
Data publikacji:
2003
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
system diagnostyczny
układy energoelektroniczne
Opis:
An assumption was made in this paper that monitoring both the converter and its control means actually continuous formulation (i.e. repeatedly) of diagnoses of their states automatically via a suitable computer diagnostic system. In other words it is diagnosing on-line carried out in real time. The authors assume that mainly the operating signals are used for diagnostic purposes since it is not recommendable to disturb the process with any additional test signals. This paper presents a fault detection and isolation scheme for systems with modeling uncertainties where not all the state variables are measurable. The proposed fault diagnosis architecture consists of a fault detection estimator and a set of isolation estimators. Each estimator corresponds to a specific fault type. Employing orthogonal transforms made it possible to depict the power electronics state variable in terms of appropriate linear combination of base functions, so far approximated by a time set. There were families of binary orthogonal Walsh and Haar functions used in the investigation. The presented approach may be considered a numeric-analytical method. The investigation of power electronic converter signals was carried out using fast processing algorithms.
W pracy przyjęto, że monitorowanie przekształtnika i jego sterowania jest prowadzone w sposób ciągły (cyklicznie) poprzez automatyczne formułowanie diagnoz jego stanu przez komputerowy system diagnostyczny. Innymi słowy diagnozowanie jest prowadzane w czasie rzeczywistym. Autorzy zakładali, że jako sygnały diagnostyczne użyte będą sygnały procesu, ponieważ wprowadzanie dodatkowych sygnałów testowych mogło by zakłócać jego dynamikę. Praca przedstawia układ wykrywania i lokalizacji uszkodzeń układu energoelektronicznego zawierającego niedokładnie określone parametry przy braku możliwości pomiaru wszystkich zmiennych stanu. Zaproponowana architektura diagnostyki uszkodzeń obejmuje estymator ich wykrywania oraz zbiór estymatorów lokalizacji. Każdy estymator lokalizacji odpowiada konkretnemu typowi uszkodzenia. Zastosowanie przekształceń ortogonalnych umożliwia przedstawienie zmiennej stanu układu energoelektronicznego w postaci odpowiednich kombinacji liniowej funkcji bazowych, dotychczas aproksymowanej szeregiem czasowym. W badaniach zastosowano rodziny binarnych funkcji ortogonalnych Walsha i Haara. Opisane podejście można zaliczyć do metod analityczno - numerycznych. Badanie własności sygnałów przekształtników energoelektronicznych przeprowadzono w oparciu o opracowane przez autorów algorytmy szybkich przekształceń.
Źródło:
Prace Instytutu Elektrotechniki; 2003, 218; 61-78
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault detection in power electronics systems based on qualitative and quantitative models
Detekcja uszkodzeń w układach energoelektronicznych oparta na modelach jakościowych i ilościowych
Autorzy:
Juszczyk, W.
Kich, Z.R.
Zając, M.
Powiązania:
https://bibliotekanauki.pl/articles/158608.pdf
Data publikacji:
2002
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Opis:
It is assumed in this paper that monitoring both the converter and its control states means continuous formulation (i.e. in a repeatable way) of a diagnosis of the plant's state automatically via a suitable computer diagnostic system. In other words it is on-line diagnosing carried out in real time. The authors assume that mainly the operating signals are used for diagnostic purposes since it is not recommendable to disturb the process with any additional test signals. Implementation of the orthogonal expansion made it possible to depict the system state approximated by a sequence of its values' observations in a form of some linear combination of basic functions. Complete families of binary orthogonal Walsh and Haar functions are emploed. The employed research methods may be considered numeric-analytical ones. The investigation of the signal properties in power electronics inverters was carried out using fast processing algorithms (both in serial and parallel modes). Along with the simulational modeling the presented approach made it possible to execute a complex fault detection and isolation for a typical arrangement of the inverter. The fast transform algorithm used in this paper is based on the Haar matrix factorization.
Przyjęto, że monitorowanie stanu wybranego przekształtnika i jego układu sterowania jest powtarzalnym cyklicznie w sposób automatyczny komputerowym formułowaniem diagnoz o jego stanie. Innymi słowy jest to diagnozowanie prowadzone na bieżąco w czasie rzeczywistym. Autorzy założyli, że do celów diagnostyki układów energoelektronicznych wykorzystywane są głównie sygnały robocze, niewskazanym jest bowiem zakłócanie procesu dodatkowymi sygnałami testowymi. Przedstawione typowe schematy możliwych testów diagnostycznych używanych do oceny własności wybranych sygnałów przekształtnika, oraz sklasyfikowano spotykane w literaturze metody detekcji uszkodzeń, które mogą znaleźć zastosowanie do oceny niezawodności działania podobnych układów energoelektronicznych. Przedstawiono schemat blokowy procesu monitorowania przekształtnika. Szczególną uwagę zwrócono na przyczyny istnienia opóźnień czasowych powstawania symptomów. Sklasyfikowano czynniki od których zależą te opóźnienia. Zaproponowano formalizację opisu stanu pracy przekształtnika i opisu możliwych testów diagnostycznych. Do badań wybrano testy oparte na zastosowaniu analizy spektralnej sygnałów. Obiektem badań był typowy prostownik sterowany. Zastosowanie teorii rozwinięć ortogonalnych umożliwiło przedstawienie stanu układu aproksymowanego ciągiem obserwacji jego wartości w postaci pewnej kombinacji liniowej funkcji bazowych. W badaniach zastosowano pełne rodziny binarnych funkcji ortogonalnych Walsha i Haara. Użyty w tej pracy algorytm szybkiego przekształcenia oparto na faktoryzacji macierzy Haara. Zastosowane metody badawcze można zaliczyć do metod numeryczno-analitycznych. Badania własności sygnałów prostownika przeprowadzono w oparciu o wykorzystanie szybkich algorytmów przetwarzania (w wersjach szeregowej i równoległej). Wykazały one swą przydatność dla formułowania diagnoz o miejscach i zakresach pojawiania się typowych uszkodzeń w zasilaniu, sterowaniu czy też obciążeniu prostownika. W połączeniu z modelowaniem symulacyjnym prezentowane podejście pozwoliło na przeprowadzenie kompleksowego procesu detekcji i lokalizacji uszkodzeń dla typowego układu prostownika sterowanego.
Źródło:
Prace Instytutu Elektrotechniki; 2002, 211; 167-202
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies