Tytuł:
Corrosion Resistance, EIS and Wettability of the Implants Made of 316 LVM Steel Used in Chest Deformation Treatment
Autorzy:
Kajzer, A.
Kajzer, W.
Gołombek, K.
Knol, M.
Dzielicki, J.
Walke, W.
Powiązania:
https://bibliotekanauki.pl/articles/355260.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stainless steel
corrosion resistance
wettability
plate
Opis:
The paper presents the influence of mechanical surface damage on the physicochemical properties of plates after implantation made of CrNiMo stainless steel, used in the treatment of anterior surface deformity of the chest. Analysis of the data allowed us to investigate the effect of implant design and condition of their surface on the results of chest deformation treatment. Results of electrochemical, impedance and surface wettability tests and SEM observations were compared with clinical observations. When removing the plates we found only slight inflammatory-periosteal reactions. On the basis of obtained results, it can be stated that plates, in spite of mechanical damage of the surface, were characterized by good corrosion resistance, a fact which is confirmed by the results of clinical evaluation.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 767-770
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność korozyjna stopu Co-Cr-W-Ni (L605) w wybranych płynach fizjologicznych
Corrosion resistance of Co-Cr-W-Ni (L605) alloy in simulated body fluids
Autorzy:
Kajzer, W.
Marciniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/285689.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomateriały metalowe
odporność korozyjna
implanty
metallic biomaterials
corrosion resistance
implants
Źródło:
Engineering of Biomaterials; 2008, 11, no. 77-80; 76-79
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność korozyjna stopu Co-Cr-W-Ni (L605) w wybranych płynach fizjologicznych
Corrosion resistance of Co-Cr-W-Ni (L605) alloy in simulated body fluids
Autorzy:
Kajzer, W.
Marciniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/286243.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
odporność korozyjna
implanty
biomateriały metalowe
corrosion resistance
implants
metallic biomaterials
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 241-243
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Corrosion Resistance of Titanium Alloys Used for Medical Implants
Autorzy:
Szewczenko, J.
Marciniak, J.
Kajzer, W.
Kajzer, A.
Powiązania:
https://bibliotekanauki.pl/articles/351507.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metallic biomaterials
titanium alloys
corrosion resistance
mechanical processing
anodic oxidation
Opis:
The study presents the results of investigations of modeling the usable properties of implant surfaces made of Ti6Al7Nb alloy, using the example of a dynamic hip screw (DHS) applied in surgical treatment of intertrochanteric femoral neck fractures. Numerical simulation has been performed for the model load of femoral fixation with DHS screw. The load simulation results provided the basis to select mechanical properties of the fixator elements and to define those fixation areas which are mostly susceptible to development of corrosion. The surfaces of Ti6Al7Nb alloy were ground, vibro-abrasive machined, mechanically polished, sandblasted, anode oxidized at different voltage values and steam sterilized. Results of surface topography evaluation, resistance to pitting and crevice corrosion as well as degradation kinetics of the outer layer were presented. Usability of the formed passive layer in clinical applications was evaluated through wear and corrosion tests of the femoral fixation model. The test results proved usefulness of the proposed surface modification methods for clinical application of different size and shape implants.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 695-700
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The study of physicochemical properties of stabilizing plates removed from the body after treatment of pectus excavatum
Autorzy:
Kajzer, A.
Kajzer, W.
Dzielicki, J.
Matejczyk, D.
Powiązania:
https://bibliotekanauki.pl/articles/307068.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biomateriały
obserwacja kliniczna
odporność korozyjna
stabilizing plate
corrosion resistance
clinical assessment
Opis:
This paper presents the results of a physicochemical surface study and clinical observation of a new generation of plates for the treatment of pectus excavatum. Analysis of the data allowed us to investigate the effect of implant design and condition of their surface on the results of treatment of pectus excavatum. In the study, we performed an analysis of clinical data, obtained after a suitable period of treatment with the use of implants, as well as a study of physicochemical properties of stabilizing plates after their removal from the body. Surface roughness, the surface wettability and corrosion resistance were measured, and the results were compared with clinical observations. When removing the plates we found only slight inflammatory-periosteal reactions around the wire fixing transverse stabilizing plates to the ribs and locking the base plate correcting the distortion. The corrective plates did not shift or rotate during the entire treatment period, giving an optimal, oval and natural shape of the chest. The obtained values of the parameters investigated indicate that the reduction in resistance to pitting corrosion occurred in the areas where laser marking was made to identify the plate. The remaining plates, in spite of mechanical damage of the surface, were characterized by good corrosion resistance, a fact which is confirmed by the results of clinical evaluation.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 2; 35-44
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potentiostatic, Potentiodynamic and Impedance Study of TiO2 Layers Deposited of 316 LVM Steel Used for Coronary Stents
Autorzy:
Basiaga, M.
Staszuk, M.
Walke, W.
Tański, T.
Kajzer, W.
Powiązania:
https://bibliotekanauki.pl/articles/354433.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AISI 316LVM
TiO2 layer
ALD method
coronary stents
corrosion resistance
Opis:
The objective of the study is assessment of suitability of the ALD method for application of a TiO2 layer on surface of 316LVM steel used for production of vessel stents. Selection of the appropriate process parameters for application of the layer affects its electrochemical properties, which largely determine resistance of the biomaterial to corrosion in the blood environment, thus affecting its hemocompatibility. To assess resistance of the AISI 316LVM steel with modified surface to corrosion, voltammetric and impedance measurements were conducted. The proposed variant of surface processing allows safe deformation of the TiO2 layer without its delamination.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 821-824
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie własności fizykochemicznych bezcementowych panewek stawu biodrowego
Electrochemical study of uncemented hip endoprosthesis cups
Autorzy:
Kajzer, W.
Kajzer, A.
Grzeszczuk, O.
Semenowicz, J.
Mroczka, A.
Powiązania:
https://bibliotekanauki.pl/articles/284760.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stal Cr-Ni-Mo
panewka stawu biodrowego
odporność korozyjna
stainless steel
hip endoprosthesis
corrosion resistance
Opis:
Celem prowadzonych badań było porównanie własności panewki nowej oraz po alloplastyce rewizyjnej przebywającej w organizmie człowieka przez 68 miesięcy. W ramach badań przeprowadzono analizę składu chemicznego, własności mechanicznych oraz fizykochemicznych. Własności te analizowano na podstawie badań z wykorzystaniem optycznej spektrometrii emisyjnej ze wzbudzeniem jarzeniowym, pomiarów twardości oraz badań potencjodynamicznych odporności na korozję wżerową i elektrochemicznej spektroskopii impedancyjnej EIS. Badanie elektrochemiczne przeprowadzono w roztworze Ringera. Dodatkowo przeprowadzono analizę makroskopową powierzchni. Na podstawie przeprowadzonych badań stwierdzono, że badane panewki zostały wytworzone ze stali Cr-Ni-Mo spełniającej zalecenia normy ISO 5832-9. Wyniki pomiarów twardości ujawniły obszary o zróżnicowanym umocnieniu biomateriału panewki. Uzyskane parametry odporności korozyjnej dla panewki po implantacji były porównywalne do wartości uzyskanych dla panewki w stanie wyjściowym. Dodatkowo przeprowadzone badania EIS określiły charakter warstwy tlenkowej występującej na powierzchni implantu po usunięciu z organizmu. Wykazały one występowanie warstwy podwójnej stanowiące dobre zabezpieczenie biomateriału metalowego przed rozwojem niekorzystnych zjawisk korozyjnych. Natomiast przeprowadzone obserwacje makroskopowe ujawniły występowanie warstwy hydroksyapatytu na powierzchni panewki po 68-miesięcznym przebywaniu w organizmie. Podsumowując można stwierdzić, że przyczyną alloplastyki rewizyjnej był brak osteointegracji powierzchni zewnętrznej implantu spowodowany nierównomiernym przyleganiem implantu do powierzchni kości. Nie zaobserwowano jednak zmniejszenia odporności korozyjnej panewki po implantacji, co wskazuje na jej biokompatybilność w środowisku tkankowym.
The aim of the research was to compare the properties of the new cup and the cup after alloplastic revision surgery which has been staying in the human body for 68 months. In the studies chemical composition, mechanical and physicochemical properties were analyzed. The properties were analyzed on the basis of studies of glow discharge atomic emission, measurements of hardness and potentiodynamic studies of resistance to pitting corrosion and electrochemical impedance spectroscopy (EIS). The electrochemical research was conducted in Ringer’s solution. Additionally, analysis of the macroscopic surface was conducted. The results revealed that the cups were produced from high nitrogen stainless steel which chemical composition and mechanical properties met the requirements of the ISO 5832-9 standards. The results of hardness revealed areas with varied strengthening of the cup’s biomaterial. Parameters of the corrosion resistance for the cup after implantation were comparable to the values obtained for the cup in the initial state. Additionally, EIS study determined the nature of the oxide layer on the surface of the implant removed from the body. The results showed the existence of a double layer forming good protection of the metal biomaterial against corrosion. The performed macroscopic observation revealed the presence of hydroxyapatite on the surface of the cup after the 68 months in the body. We conclude that the reason for revision arthroplasty was the lack of osteointegration of the outer surface of the implant caused by non- -uniform adhesion of the implant to the bone surface. However, no reduction in corrosion resistance of the cup after implantation was observed which indicates its biocompatibility in the tissue environment.
Źródło:
Engineering of Biomaterials; 2015, 18, 132; 9-16
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion resistance of PLGA-coated biomaterials
Autorzy:
Szewczenko, J.
Kajzer, W.
Grygiel-Pradelok, M.
Jaworska, J.
Jelonek, K.
Nowińska, K.
Gawliczek, M.
Libera, M.
Marcinkowski, A.
Kasperczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/306888.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
odporność korozyjna
stopy tytanu
stal nierdzewna
PLGA
corrosion resistance
titanium alloys
stainless steel
degradation
biodegradable coatings
Opis:
The aim of the study was to determine the influence of PLGA bioresorbable polymer coating on corrosion resistance of metal biomaterial. Polymer coating deposited by immersion method was applied. Corrosion resistance of metal biomaterials (stainless steel, Ti6Al4V, Ti6Al7Nb) coated with PLGA polymer, after 90 days exposure to Ringer’s solution was tested. The amount of metal ions released to the solution was also investigated (inductively coupled plasma–atomic emission spectrometry (ICP-AES) method). The surface of the samples was observed using atomic force microscopy (AFM) and scanning electron microscopy (SEM). Degradation of PLGA was monitored with the use of the 1 H NMR spectroscopy and GPC (Gel Permeation Chromatography). The studies were carried out for non-sterilized (NS) and sterilized (S) samples. Application of the polymer coating causes a reduction of release of metal ions to the solution. Depending on metal substrate different course of destruction of polymer layer was observed. After 90 days of incubation in Ringer’s solution polymer layer was highly degraded, however, the composition of copolymer (ratio of the comonomeric units in the chain) remained unchanged during the whole process, which suggests even degradation. The polymer layer reduced degradation kinetics of the metal substrate. Moreover, degradation process did not change surface morphology of metal substrate and did not disturb its integrity. The results obtained indicate that the applied polymer layer improves corrosion resistance of the alloys being investigated. Thus, the developed implants with bioresorbable coatings could be advantageous for medical applications.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 1; 173-179
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ modyfikacji powierzchni na własności fizykochemiczne tytanu stosowanego na implanty do kontaktu z krwią
Influence of surface modification on physicochemical properties of titanium used for bloodcontacting implants
Autorzy:
Kajzer, A.
Paszenda, Z.
Basiaga, M.
Walke, W.
Kajzer, W.
Powiązania:
https://bibliotekanauki.pl/articles/284177.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
tytan cpTi
utlenianie anodowe
zwilżalność
odporność korozyjna
obróbka powierzchniowa
titanium cpTi
anodic oxidation
wettability
corrosion resistance
surface treatment
Opis:
Celem prowadzonych badań było określenie wpływu procesu utleniania anodowego powierzchni na własności fizykochemiczne tytanu. Wyniki badań stanowią podstawę do doboru optymalnych warunków utleniania anodowego do zastosowań na implanty do kontaktu z krwią. W ramach badań dla próbek w stanie wyjściowym oraz poddanych procesowi utleniania przy potencjałach od 40 V do 100 V co 10 V przeprowadzono ocenę zwilżalności powierzchni, badania potencjodynamiczne oraz impedancyjne. Na podstawie analizy uzyskanych wyników stwierdzono, że niezależnie od zastosowanego potencjału anodyzacji proces ten spowodował korzystne zwiększenie się potencjału korozyjnego E/kor oraz zwiększenie oporu polaryzacyjnego Rp w odniesieniu do próbek w stanie wyjściowym. Natomiast optymalny wariant przygotowania powierzchni, która będzie kontaktowała się z płytkami krwi stanowi utlenianie anodowe przy potencjale 100 V. Spowodowało ono znaczny wzrost oporu przejścia jonów na granicy faz Rct oraz wyeliminowanie elementu Warburga z układu zastępczego w stosunku do pozostałych analizowanych wariantów, co świadczy o bardzo dobrych własnościach ochronnych wytworzonej w ten sposób warstwy tlenkowej. Dla tak przygotowanej powierzchni stwierdzono najmniejszą zwilżalność oraz największą odporność korozyjną, co zapewnia zmniejszoną aktywację oraz adhezję płytek krwi do podłoża oraz biotolerancję w analizowanym środowisku. Wiadomo, że materiał o wysokim potencjale trombogennym powoduje adsorpcję materiału biologicznego na powierzchni oraz aktywację układu trombocytarnego, w wyniku czego wzrasta ryzyko powstawania między innymi powikłań zatorowo-zakrzepowych. Dlatego też przeprowadzone badania stanowią etap wstępny do analizy trombogenności powierzchni metodą Impact-R.
The aim of the research carried out was the determination of the influence of surface anodic oxidation process to physiochemical properties of titanium. Results form a basis for selecting optimum conditions of anodic oxidation for implants to be in direct contact with blood. The evaluation of surface wettability, potentiodynamical and impedance tests were conducted for samples at their initial condition and after they were subjected to the anodic oxidation process from 40 to 100 V every 10 V. The results revealed that regardless of the anodizing parameters applied the process has caused an advantageous decrease in corrosion potential E/kor and an decrease in polarisation resistance Rp in comparison to samples at their initial state. The optimum variant of surface that is meant to exist in direct contact with blood consists of anodic oxidation at 100 V. It has caused a substantial increase in ions transition residence Rct, increase at the interphase as well as elimination of the Warburg element from a substitute system compared to the remaining variants being analysed. This demonstrates the very good protective properties of an oxide layer obtained in this way. In the case of a surface treated in such a way, the lowest wettability and the highest corrosion residence have been found thus assuring a decreased activation and blood platelets adhesion to the substrate as well as higher biotolerance in the environment. It is known that materials having a high thrombogenic potential cause the adsorption of biological matter on the surface and the activation of thrombocytic system causing the increase of the risk of embolic and clot complications. That is why researches make an initial stage for the analysis of thrombogenic properties of surfaces according to the Impact-R method.
Źródło:
Engineering of Biomaterials; 2014, 17, 126; 23-30
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion resistance of Ti6Al4V alloy coated with caprolactone-based biodegradable polymeric coatings
Odporność korozyjna stopu Ti6Al4V pokrytego biodegradowalnymi powłokami polimerowymi na bazie kaprolaktonu
Autorzy:
Kajzer, W.
Jaworska, J.
Jelonek, K.
Szewczenko, J.
Kajzer, A.
Nowińska, K.
Hercog, A.
Kaczmarek, M.
Kasperczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/1365372.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
corrosion resistance
metal biomaterials
Ti6Al4V alloy
biodegradable polymeric coatings
odporność korozyjna
biomateriały metalowe
stop Ti6Al4V
biodegradowalne powłoki polimerowe
Opis:
The aim of this study was to determine the influence of long-term exposure of Ringer’s solution on degradation of the anodically oxidated Ti6Al4V alloy coated with a biodegradable polymer coating. Polymeric coatings made of poly(glycolide-ε-caprolactone) – G-Cap and poly(glycolide- ε-caprolactone-lactide) – G-Cap-L were applied by a dip-coating method. Degradation was assessed on the basis of the results of pitting corrosion resistance and density of metal ions infiltrating to the solution. Studies were conducted for samples after 3, 6, 8, 10 and 12 weeks of exposure to the corrosive environment. In addition, topography of the surface of the polymer coating was assessed. As a result of potentiodynamic studies, the value of the polarization resistance and corrosion potential for the G-Cap and G-Cap-L coated samples were significantly decreased while simultaneous reduction of the density of metal ions infiltrating to the solution throughout the whole study period. There was also observed a faster degradation of the G-Cap coating compared to G-Cap-L, which showed local discontinuity after 12 weeks of exposure. The obtained results provide the basis for the development of polymeric coatings on surface of metal implants with predictable time / kinetics of degradation by selecting the composition of polymers while simultaneous limitation of metal ions infiltration into surrounding tissues.
Celem pracy było określenie wpływu długotrwałego oddziaływania rozworu Ringera na proces degradacji utlenianego anodowo stopu Ti6Al4V pokrytego powłoką biodegradowalnego polimeru. Powłoki polimerowe wykonane z poli(glikolido- ε-kaprolaktonu) – G-Cap oraz poli(glikolido ε-kaprolaktono- laktydu) – G-Cap-L naniesiono metodą zanurzeniową (dip-coating). Proces degradacji w funkcji czasu oceniano na podstawie wyników badań odporności na korozję wżerową oraz gęstości masy jonów metalowych przenikających do roztworu. Badania przeprowadzono dla próbek po 3, 6, 8, 10 i 12 tygodniach ekspozycji na środowisko korozyjne. Ponadto oceniano topografię powierzchni powłoki polimerowej. W wyniku przeprowadzonych badań potencjodynamicznych stwierdzono wyraźne obniżenie wartości oporu polaryzacyjnego i potencjału korozyjnego dla próbek z naniesionymi powłokami G-Cap i G-Cap-L przy jednoczesnym wyraźnym ograniczeniu gęstości jonów metalowych przenikających do roztworu w całym okresie badawczym. Stwierdzono również szybszą degradację powłoki typu G-Cap w porównaniu do G-Cap-L, dla której po 12 tygodniu ekspozycji stwierdzono lokalnie występujące przerwania ciągłości. Uzyskane wyniki dają podstawę do opracowywania na powierzchni implantów metalowych powłok polimerowych o przewidywalnym czasie/określonej kinetyce degradacji, poprzez dobór składu polimerów z jednoczesnym ograniczeniem możliwości przenikania jonów metalowych do otaczających tkanek.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 1; 30-38
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface Modification Of Implants For Bone Surgery
Modyfikacja powierzchni implantów ortopedycznych
Autorzy:
Marciniak, J.
Szewczenko, J.
Kajzer, W.
Powiązania:
https://bibliotekanauki.pl/articles/355874.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AISI 316L stainless steel
Titanium alloy Ti6Al4V
surface layer
corrosion and wear resistance
biocompatibility
stal nierdzewna AISI 316L
stop tytanu Ti-6Al-4V
warstwa powierzchniowa
korozja i odporność na ścieranie
biokompatybilność
Opis:
The study discusses the methods of surface modification methods for AISAI 316 L steel and Ti6Al4V ELI titanium alloy, dedicated to complex design implants used in bone surgery. Results of structural tests have been presented along with those evaluating the physicochemical properties of the formed surface layers. Clinical feasibility of the surface layers has also been evaluated. The developed surface modification methods improved the resistance to pitting, crevice and stress corrosion and ensured better biocompatibility. Moreover, the layers formed are marked by plasticity. Results of the tests performed show applicability of the evaluated methods of surface modification in complex shape implants for the clinical use.
W pracy omówiono metody modyfikacji powierzchni stali AISAI 316 L oraz stopu tytanu Ti6Al4V ELI przeznaczonych na implanty o złożonej konstrukcji stosowanych w chirurgii kostnej. Przedstawiono wyniki badań struktury oraz własności fizykochemicznych wytworzonych warstw wierzchnich. Określono również przydatność wytworzonych warstw do zastosowań klinicznych. Opracowane metody modyfikacji powierzchni zwiększyły odporność na korozję wżerową, szczelinową i naprężeniową oraz poprawiły biokompatybilności. Ponadto wytworzone warstwy cechują się podatnością do odkształceń. Wyniki badań wykazały przydatność zastosowanych metod modyfikowania powierzchni implantów o złożonych kształtach do zastosowań klinicznych.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3; 2123-2129
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies