Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "treatment system" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
The effect of heavy precipitation on the infiltration and inflow into small sewage treatment plants in 2010
Autorzy:
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/60233.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
heavy rainfall
infiltration
inflow
small sewage treatment plant
sewage treatment plant
sewer system
weather
treatment plant
Malopolska voivodship
Krakow city
mechanical treatment plant
biological treatment plant
modernization
Opis:
The aim of the study was to determine the extent to which heavy rainfall, that occurred in 2010, affected the infiltration into the selected sewage treatment plants in the Małopolskie voivodeship. The research was conducted in four separate sewer systems, located in poviats adjacent to the city of Kraków, discharging sewage to mechanical-biological treatment plants with a capacity below 1000 m3•d-1. The amount of sewage and extraneous water in the average wet year (2008) were used as control. As a result of heavy precipitation in 2010 the sewer system A received 18 539 m3 more extraneous water than in 2008 (increase by 343%), the sewer sys-tem B - 22 822 m3 (increase by 163%), the sewer system C - 109 715 m3 (increase by 248%) and the sewer system D - 30 796 m3 (increase by 303%). Heavy precipitation in 2010 caused the increase of infiltration and inflow by 264% on average in all studied sewer systems compared to the average wet year. As the result of precipitation, whose annual total in 2010 was higher by 65% than the normal value in 2008, there was an increase in the annual share of extraneous water from 5.3 to 19.7% depending on the facility. The volume of extraneous water, which was discharged into the studied treatment plants in 2010 (the period of heavy rainfall), constituted the following share of the annual value: in the sewer system A - 41.3%, in the sewer system B - 21.2%, in the sewer system C - 14.4%, in the sewer system D - 22.9%. Assuming the average gross amount of 3 PLN paid for treatment of 1 m3 of sewage, cost of extraneous water disposal in 2010 amounted from 78 533 PLN to 552 165 PLN, depending on the facility. The results obtained in the present study suggest that eliminating or reducing infiltration and inflow into the analyzed sewer systems would allow for large financial savings associated with reducing costs both for their transport and treatment as well as for modernization of facilities to enhance their hydraulic eapacity.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 12
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lokalizacji oczyszczalni na temperaturę dopływających do niej ścieków
Influence of treatment plant location on temperature of inflowing sewage
Autorzy:
Kaczor, G.
Bugajski, P.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/101199.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnia ścieków
ścieki
kanalizacja
temperatura ścieków
wastewater treatment plant
wastewater
sewage system
wastewater temperature
Opis:
Celem przeprowadzonych badań było uzyskanie wiedzy, jak umiejscowienie oczyszczalni względem zlewni kanalizacyjnej wpływa na temperaturę dopływających do niej ścieków. Analizą objęto cztery systemy kanalizacyjne, różniące się długością kolektora tranzytowego pomiędzy oczyszczalnią a zabudowaniami mieszkalnymi, w których wytwarzane były ścieki bytowe. W badanych systemach kanalizacyjnych ścieki odprowadzane były do oczyszczalni o przepustowości hydraulicznej od 100 do 300 m3·d-1, charakteryzujących się liczbą RLM nie większą niż 2000. Pomiary temperatury ścieków odpływających z kanalizacji oraz powietrza atmosferycznego, w analizowanym roku 2012, prowadzono w sposób ciągły, z interwałem 1 godzinnym, za pomocą czujników rezystancyjnych połączonych z rejestratorami danych. Przeprowadzone badania wykazały, że odległość oczyszczalni od zlewni kanalizacyjnej wywiera istotny wpływ na temperaturę ścieków odpływających z sieci kanalizacyjnej. W okresie zimowym średnia dobowa temperatura ścieków odpływających z kolektorów tranzytowych o długości od 300 do 600 m była niższa nawet o blisko 3ºC, natomiast w okresie letnim aż o 8ºC, w porównaniu do kolektorów tranzytowych o długości nieprzekraczającej 10 m. Wykazano ponadto, że na temperaturę ścieków dopływających do oczyszczalni, oprócz długości kolektora tranzytowego, istotnie wpływa także natężenie przepływu ścieków. Przy wzroście natężenia odpływu ścieków z kanalizacji o 100%, ich temperatura może wzrosnąć w okresie zimowym o 1ºC, natomiast w letnim o 3ºC. W przypadku sieci kanalizacyjnych zakończonych długimi kolektorami tranzytowymi, niekorzystnemu skróceniu ulega czas trwania temperatury ścieków optymalnej w aspekcie usuwania związków biogennych, a przy tym jednocześnie wydłuża się czas trwania temperatury ścieków niekorzystnej dla ich biologicznego oczyszczania.
The aim of the research was to get the expertise, how location of wastewater treatment plant to basin of sewage system influences the temperature of inflowing wastewater. The analysis included four sewage systems, which are different for the sake of length of transit canal between treatment plant and residential buildings, in which domestic sewage was produced. In analysed systems sewage flew into the treatment plants with hydraulic capacity range from 100 to 300 m3·d-1, and with population equivalent less than 2000. Measurements of temperature of air and wastewater outflowing from sewage system, in analysed year 2012, were conducted continuously, with 1 hour interval, with use resistance sensors connected with data recorder. The research showed, that the distance of treatment plant to basin of sewage system has a significant impact on wastewater temperature outflowing from sewage system. In winter period mean daily wastewater temperature outflowing from transit manifolds with length from 300 to 600 m was lower even about 3ºC, but in summer period up to 8ºC, in comparison to transit manifolds with length less than 10 m. Moreover, it was proved that, apart from length of transit manifold, also intensity of wastewater flow has a significant impact on wastewater temperature flowing into the treatment plant. With increase of intensity of wastewater flow about 100%, its temperature can increase in winter period about 1ºC, and about 3ºC in summer period. In case of sewage systems ended with long transit manifold, the duration time of optimal sewage temperature in terms of biogenic compounds removal is unfavourable reduced, and at the same time the duration time of wastewater temperature unfavourable for its biological treatment is extended.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 615-626
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ sumy rocznej opadów atmosferycznych na objętość wód przypadkowych dopływających do kanalizacji sanitarnej
The Effect of Total Annual Precipitation on the Volume of Accidental Water Entering Sanitary Sewage System
Autorzy:
Kaczor, G.
Chmielowski, K.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1813833.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
kanalizacja
ścieki
wody przypadkowe
opady
oczyszczalnia ścieków
sewerage system
sewage
accidental waters
precipitation
sewage treatment plant
Opis:
Celem badań była ocena siły korelacji pomiędzy roczną sumą opadów atmosferycznych i roczną objętością wód przypadkowych dopływających do 3 wybranych sieci kanalizacyjnych. Wody przypadkowe to najczęściej wody opadowe lub roztopowe przedostające się do wnętrza kanałów sanitarnych przez włazy studni kanalizacyjnych oraz nielegalnie wykonywane włączenia do przykanalików wylotów rynien dachowych, wpustów podwórzowych lub wylotów drenaży służących do odwodnienia posesji. Analizę oparto na 12 letnich ciągach pomiarowych, obejmujących sumy roczne opadów atmosferycznych dla Krakowa oraz roczne objętości wód przypadkowych dopływających do 3 rozdzielczych sieci kanalizacyjnych, odprowadzających ścieki bytowe z osiedli mieszkaniowych w latach 2004-2015. Przeprowadzone badania wykazały istotną statystycznie, bardzo wysoka korelację pomiędzy roczną sumą opadów atmosferycznych i roczną objętością wód przypadkowych dopływających do badanych sieci kanalizacyjnych. Na podstawie równań funkcji regresji obliczono, że wzrost sumy rocznej opadów o 100 mm spowoduje wzrost rocznej objętości wód przypadkowych dopływających do analizowanych kanalizacji od 2 305 aż do 14 866 m3. Uzyskane wyniki badań, powinny być sygnałem do podjęcia przez eksploatatorów sieci kanalizacyjnych intensywnych i skutecznych działań mających na celu wyeliminowanie nielegalnych podłączeń rynien dachowych lub wpustów podwórzowych do kolektorów sanitarnych.
The aim of the study was to find out the strength of the correlation between total annual precipitation and annual volume of accidental water entering three selected sewerage systems. Accidental water is usually precipitation or melt water entering the sanitary sewers via manhole wells or the outlets of rain gutters, yard gullies or local drainage systems illegally connected to the drains. The analysis included 12-year measurement series covering total annual precipitation for Kraków and annual volume of accidental water entering three distribution sewerage networks discharging domestic sewage from residential areas in the years 2004-2005. The study revealed a significant and very strong correlation between total annual precipitation and annual volume of accidental water entering the investigated sewerage systems. Results if regression equations showed that a 100 mm increase in total annual precipitation would enhance will the annual volume of accidental water supplied to the analyzed sewerage systems from 2 305 up to 14 866 m3. This clearly indicates the need to intensify the efforts aimed at elimination of illegal connections of rain gutters and yard gullies to the investigated sewerage systems.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 668-681
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies