Tytuł:
Effectiveness of shear strengthening of walls made using AAC blocks - laboratory test results
Efektywność wzmocnienia na ścinanie ścian wykonanych z bloczków ABK - wyniki badań laboratoryjnych
Autorzy:
Kałuża, M.
Powiązania:
https://bibliotekanauki.pl/articles/230383.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
konstrukcja murowa
wzmocnienie
FRP
FRCM
ścinanie
bloczek ABK
beton komórkowy
efektywność
masonry structure
strengthening
in-plane shearing
effectiveness
AAC block
Opis:
The selection of the most proper strengthening method/system with an assessment of its effectiveness is quite complicated in the case of masonry structures, mainly due to their huge diversity in materials. The most popular strengthening materials based on the composite fibres and are laid on the masonry wall using epoxy adhesives (FRP system) or mineral mortars (FRCM system). This article presents a comparison of external strengthening made using different glass-fibre-based materials on the behaviour of specific masonry walls. The walls are made of AAC blocks (Autoclaved Aerated Concrete), commonly used in rather low urban buildings or skeleton construction. As a strengthening material the GFRP sheets and two types of glass meshes are used. The walls are subjected to diagonal compression, which reflects the shearing of the walls. The scope of research describes cracking stage, shear capacity and analysis of the mode of failure of tested walls.
Artykuł przedstawia porównanie efektywności powierzchniowego wzmocnienia materiałami kompozytowymi ścian wykonanych z bloczków z betonu komórkowego (ABK), które poddano ścinaniu w płaszczyźnie. Przeprowadzono badania 14 modeli o wymiarach 805×900×240 mm, z czego 4 były niewzmocnione, a 10 wzmocniono przy użyciu materiałów na bazie włókien szklanych. Zastosowano dwa sposoby wzmocnienia: system FRP, w którym maty szklane (w dwóch ułożeniach) przyklejono do modeli przy użyciu żywicy epoksydowej i system FRCM, gdzie siatki szklane układano na zaprawach mineralnych. W drugim systemie przebadano dwa rozwiązania: nietypowe, wykorzystujące materiały do prac tynkarskich i systemowe dedykowane do wzmacniania murów. Elementy przebadano w układzie ukośnego ściskania, który odzwierciedlał rzeczywisty schemat ścinania ścian. Zaobserwowano, że w przypadku konstrukcji niewzmocnionej pojawienie się ukośnego zarysowania było równoznaczne ze zniszczeniem muru, który rozpadał się na niezależne części. Zniszczenie to miało gwałtowny i nagły charakter, co uznano za niebezpieczny sposób zniszczenia konstrukcji.
Źródło:
Archives of Civil Engineering; 2020, 66, 2; 33-44
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problem nagrzewania pierścieni pośrednich stosowanych w badaniach termowizyjnych
Problem of heating-up extension tubes used for thermographic measurements
Autorzy:
Kałuża, M.
Powiązania:
https://bibliotekanauki.pl/articles/154524.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary termowizyjne
pierścień pośredni
obiektyw
thermographic measurements
extension tube
camera lens
Opis:
W przypadku konieczności obrazowania termowizyjnego obiektów o małych rozmiarach, z rozdzielczością sięgająca kilku lub kilkunastu mikrometrów na piksel, w kamerach termowizyjnych wykorzystywane są specjalne obiektywy mikroskopowe. W przypadku braku takiego obiektywu, alternatywą jest użycie pierścieni pośrednich, montowanych pomiędzy posiadanym obiektywem oraz obudową kamery. Zastosowanie pierścieni jest tanim i łatwo dostępnym rozwiązaniem, jeśli tylko mechaniczna budowa kamery na to pozwala. Ceną, jaką się za to płaci są jednak zniekształcenia uzyskiwanego obrazu, błędy pomiaru temperatury oraz wpływ promieniowania termicznego samych pierścieni na otrzymywane wyniki. Celem badań opisanych w niniejszym artykule było sprawdzenie, jak pierścienie pośrednie i ich nagrzewanie przez kamerę wpływają na otrzymywane wyniki pomiarów oraz na stabilizację temperatury samej kamery.
Infrared cameras has been used for years as one of the main tool for temperature measurements. When there is a need to image objects of sizes comparable to the detector matrix pixel pitch, microscope lenses are normally used. When such camera lens is for some reason not available, an interesting alternative is to use extension tubes mounted between the lens and the camera housing. However, that solution comes at the cost of: image distortions, temperature measurement errors and impact of the thermal radiation of the extension tube itself on the measurements or imaging. The goal of the research described in this paper was to investigate how screwing an extension tube to the camera housing and its heating will affect the measurement results and the temperature of the camera itself. The resume of the previous research concerning the application of extension tubes to thermography is presented in the introduction. The second section describes the physical phenomena and effects to be taken into account when adding an extension tube to an infrared camera lens, which are the modification of the imaged object - lens - detector matrix geometry leading to the changes of the configuration factor, the influence of the radiation coming from the extension tube itself and finally, the problem of the extension tube heating-up, when mounted on an IR camera. Next, in the third section there are presented the results of measurements made with an MWIR camera equipped with an extension tube and comparison of the results obtained using factory and custom non-uniformity correction. Because the impact of the thermal radiation coming from the tube itself is the greatest, when imaging objects at the room temperature or below RT, some examples of imaging of a linen composite structure (at RT, cooled or heated) are also given. The fourth section covers the conclusions based on the presented measurements results and requirements for further work. Extension tubes are an interesting alternative to microscopic lenses, especially for measurements, when only the phase of the signal is of interest. In general, extension tubes appear as an interesting tool, but care must be taken when using them, depending on the tube length, imaged object placement relatively to the lens axis, time duration of the measurement and measured object temperature. To get the best results, a custom NUC and calibration of the camera is required, along with, if possible, cooling and temperature stabilization of the tube.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1238-1241
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obrazowanie termiczne stanów przejściowych przy załączaniu tyrystora
Thermal imaging of thyristor turn-on transients
Autorzy:
Kałuża, M.
Napiórkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/154464.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
przyrządy półprzewodnikowe mocy
thermovision
power semiconductor devices
Opis:
W artykule przedstawiono wyniki badań dotyczące możliwości zastosowania kamery termowizyjnej do rejestracji termogramów szybkich procesów przejściowych generacji ciepła w czasie załączania otwartej struktury półprzewodnikowej tyrystora. Badania wykazały możliwość rejestracji termogramów w czasie załączania przyrządu półprzewodnikowego mocy przy odpowiednim doborze niestandardowych ustawień pracy kamery termowizyjnej.
The paper presents the results of investigations on possible use of a thermal imaging camera for the recording of fast transient processes of heat generation during the switching of semiconductor structures in semiconductor power devices, based on measurements of a thyristor semiconductor structure. Using a measurement setup consisting of an IR camera and of a purpose build current pulse generator, the thermal behaviour of the T00-80 thyristor semiconductor structure during turn on was investigated. The thermograms were recorded at speeds reaching 1400 frames per second. Studies of the semiconductor structure of the thyristor mounted in a special holder showed the possibility of using a thermal camera for analyzing the behaviour of power semiconductor devices, however further increase in the temporal resolution of the recording process will be needed. One of the solutions will be to synchronize operation of a pulse generator and a thermal camera, including a controlled, variable time delay between current pulse generation and image acquisition.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1199-1201
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie pierścieni pośrednich w badaniach termowizyjnych
Application of extension tubes to thermographic measurements
Autorzy:
Kałuża, M.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/157676.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary termowizyjne
pierścień pośredni
obiektyw
thermographic measurements
extension tube
camera lens
Opis:
Kamery termowizyjne są od lat jednym z podstawowych narzędzi wykorzystywanych do badań zjawisk termicznych w wielu różnych dziedzinach nauki i techniki. Ze względu na wykorzystywane długości fal, najczęściej 3-5 Μm lub też 7-14 Μm, kamery termowizyjne nie mogą korzystać ze standardowych obiektywów ze szkła krzemowego. Konieczne jest stosowanie drogich elementów optycznych, wykonywanych np. z germanu lub też szafiru. Chcąc stosować kamerę termowizyjną do zróżnicowanych zadań, począwszy od obserwacji odległych przedmiotów, poprzez badania stanu izolacji termicznej budynków, badania maszyn i urządzeń, a kończąc na mikroskopowych badaniach elementów elektronicznych, konieczne staje się wyposażenie kamery termowizyjnej w cały zestaw obiektywów, począwszy od obiektywów teleskopowych, aż po obiektywy mikroskopowe. Celem badań opisanych w niniejszym artykule było sprawdzenie możliwości zastosowania w badaniach termowizyjnych pierścieni pośrednich.
Infrared cameras has been used for years as one of the main tools for temperature measurements. Because of wavelengths employed (3-5 Μm or 7-14 Μm), infrared cameras cannot use standard lenses made of silicon glass. It is necessary to rely on expensive optical materials such as germanium or sapphire. When using an infrared camera for different tasks, such as observation of distant objects, evaluation of buildings thermal insulation, thermal measurements of transformers, power lines, thermal investigations of electronic circuits, one has to use a wide range of lenses, from telescopic to microscopic. The goal of the research was to investigate the possibility of using extension tubes for thermography for imaging objects of sizes comparable to the detector matrix pixel pitch. The general problems of macrophotography are presented in the introduction. The second section describes the physical phenomena and effects to be taken into account when adding an extension tube to infrared camera lens which are the modification of the imaged object - lens - detector matrix geometry leading to the changes of the configuration factor; the influence of the radiation coming from the extension tube itself and finally, the problem of the imaged detail size becoming comparable to the wavelength used by the detector matrix. Next, in the third section, there are presented the results of measurements taken with a MWIR camera, using various combinations of 4 extension tubes. The fourth section contains the conclusions based on the presented measurement results. Extension tubes are an interesting alternative to microscopic lenses, especially in case of measurements for which only the signal phase is of interest. In general, extension tubes appear to be an interesting tool but it should be noted that the additional camera calibration may be needed when using them, depending on the tube length, the imaged object placement in relation to the lens axis and the measured object temperature in order to avoid temperature measurement errors.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 898-901
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja bioprodukcji kwasu cytrynowego w hodowli wgłębnej Aspergillus niger prowadzonych w obecności Tweenu 80
Optimization of citric acid bioproduction in Aspergillus niger submerged cultures supplemented with Tween 80
Autorzy:
Kałuża, M.
Sadowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2072426.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
optymalizacja
metoda Boxa-Wilsona
kwas cytrynowy
Tween 80
Aspergillus niger
optimization
Box-Wilson method
citric acid
Opis:
Celem badań była maksymalizacja bioprodukcji kwasu cytrynowego w wgłębnych hodowlach A. niger prowadzonych w obecności Tweenu 80. Przeprowadzono optymalizację składu podłoża hodowlanego i warunków procesu fermentacji cytrynowej, korzystając z metody zaproponowanej przez Boxa i Wilsona. Wynikiem eksperymentu optymalizacyjnego był wzrost stężenia kwasu cytrynowego w prowadzonych hodowlach z 47,01 do 66, 37 g/dm3 oraz obniżenie zawartości białego cukru w nowo zdefiniowanym podłożu fermentacyjnym.
The aim of these experiments was to enhance the citric acid bioproduction in Aspergillus niger submerged cultures supplemented with Tween 80. To maximize the effect of citric acid fermentation, the optimization of culture medium and fermentation conditions was performed using a method proposed by Box and Wilson. The optimization result was the enhancement of citric acid concentration in fermentation broths from 47.01 to 66.37 g/dm3 and the reduction of sucrose in redefined fermentation medium.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 332--333
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of thermal impedance and wavelets analysis for non-destructive testing
Autorzy:
Kopeć, M.
Kałuża, M.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114695.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nondestructive testing
thermography
T3Ster analysis
wavelet analysis
Opis:
This paper presents a comparison of two methods used for non-destructive testing: thermal impedance (Zth) and wavelet transform (WT). The transient heating process of a textolite plate with defects was measured using a thermographic camera. Based on the measurement results, a qualitative and quantitative assessment of material structure was performed. The measured parameters describing the geometry of the tested material were temperature, time constant, angular frequency and phase. The presented results of thermographic measurements and their analysis indicate the possibility of detection of subsurface defects using both presented methods. The convergence and the correlation between results obtained using thermal impedance and wavelet methods are presented.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 223-227
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Importance of radiative heat transfer for infrared thermography measurements
Znaczenie radiacyjnej wymiany ciepła w pomiarach termowizyjnych
Autorzy:
De Mey, G.
Więcek, B.
Kałuża, M.
Olbrycht, R.
Strąkowski, R.
Strąkowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/154589.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
radiacyjna wymiana ciepła
termografia
promieniowanie podczerwone
heat transfer by radiation
thermography
infrared radiation
Opis:
The basics of heat transfer by radiation will be shortly outlined: Planck's law, Stefan Boltzmann's law, emissivity, construction of a black body, effective emissivity, reflection. Several applications for infrared thermography, basic physical principles of microbolometer detector, non uniformity correction without shutter and blocking the image and some original experiments will be discussed afterwards. The main conclusion of this work is that calibration of metrological cameras has to be performed for different temperature of their housing.
W artykule przedstawiono podstawy wymiany ciepła przez radiację: prawo Plancka, Stefana Boltzmanna, emisyjność materiałów, budowę ciała doskonale czarnego, efektywną emisyjność oraz prawo odbicia. Omówiono również niektóre aplikacje w termografii w podczerwieni, w których wykorzystuje się efekty radiacyjne. Omówiono fizyczne podstawy działania detektora mikrobolometrycznego, korekcję niejednorodności matrycy bolometrycznej bez migawki i blokowania obrazu oraz wybrane oryginalne eksperymenty. Przedstawiono wpływ promieniowania obudowy na działanie detektora i kamery termowizyjnej oraz zastosowanie pierścieni pośrednich w badaniach termowizyjnych.Niestety obudowa i pierścienie emitują pasożytnicze promieniowanie, które musi być uwzględnione w pomiarach termowizyjnych. Wnioskiem z pracy jest stwierdzenie, że w metrologicznej kamerze termowizyjnej, kalibracja powinna być przeprowadzona dla różnych wartości temperatury obudowy. Mówimy wówczas o korekcji RNU (ang. Residual Nonuniformity Correction). The work is an effect of design and building a prototype of the new infrared camera.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1112-1115
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termowizyjne badania spiralnych cewek scalonych w technologiach krzemowych
Thermal measurements of silicon integrated spiral inductors
Autorzy:
Kałuża, M.
Więcek, B.
Hatzopoulos, A.
Chatziathanasiou, V.
Papagiannopoulos, I.
De May, G.
Powiązania:
https://bibliotekanauki.pl/articles/157639.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spiralne cewki scalone
modelowanie
badania termowizyjne
thermographic measurements
spiral inductors
modeling
Opis:
Spiralne cewki scalone stanowią szczególny przypadek połączenia wewnątrzukładowego w układach scalonych. Pozwalają na bezpośrednią integrację indukcyjności w strukturach półprzewodnikowych, w standardowych technologiach CMOS/BiCMOS, bez konieczności wykonywania dodatkowych procesów technologicznych, dodatkowych fotomasek, a tym samym, bez zwiększania kosztów produkcji. W niniejszym artykule przedstawiono wyniki badań termowizyjnych spiralnych pojedynczej spiralnej cewki scalonej w technologii krzemowej i ich porównanie z wynikami symulacji.
Spiral inductors are a special case of on-chip interconnects used in integrated circuits. They enable direct integration of inductances in semiconductor structures, in standard CMOS/BiCMOS technologies, without the need of additional technological processes, additional photomasks, thus without increase in ICs production costs. Because of their relatively large sizes compared to other elements integrated on a semiconductor wafer, spiral inductors can became a source of nonnegligible interferences for neighboring circuits located on the same semiconductor structure. According to the Joule-Lenz law, a current flowing through a metal produces heat. A spiral inductor is a metal interconnect conveying current, thus one can expect that the current flowing through the spiral will heat it, changing its series resistance and changing one of the inductor key design parameters - its quality factor Q. The neighboring circuits can also be affected. So far there have hardly been any publications dealing with that subject. The goal of the research was to investigate the thermal behavior of silicon integrated spiral inductors under current stress. In the introduction, an overview of spiral inductors is presented, including their typical geometries, dimensions and applications. The second section of the paper discusses the problems of silicon integrated spiral inductor model-ing. Next, in the third section there are given the results of temperature measurements of one of the spiral inductors integrated in test circuits. A MWIR camera with a cooled InSb 640x512 pixel detector matrix was used. The measurements are compared with simulation results. The fourth section presents the conclusions drawn from the measurement results. The measurement setup used allowed the imaging of a single spiral inductor, while only a general view of the test circuit was obtained form the previous results, without the possibility to discern a single, individual spiral inductor. It is shown that there is a good agreement between the simulations and measurements. Further investigations will be required to overcome the problems encountered during the measurements, such as influence of the on-wafer probes, the order of magnitude emissivity difference between the silicon substrate and aluminum interconnects. More complicated spiral geometries will have to be investigated, especially micromachined spiral inductors, in which the inductor is suspended, and typically connected to the rest of the integrated circuit only with 4 narrow SiO2 made bridges.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 954-957
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies