Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stacja" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Pollutant concentrations from deciduous wood fuelled heat station
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/185275.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stacja ciepła
spalanie
emisja
drewno
heat station
wood
combustion
emission
Opis:
CO, NO, NO2 and dust concentrations from combustion of deciduous wood (birch, beech, lime-tree) logs and pellets in two heating boilers (15 and 25 KW), situated in a heat station were investigated. Time dependences of pollutant concentrations as well as the impact of temperature in the combustion chamber and oxygen concentration on pollutant concentrations were presented. Pollutant emission indices have been estimated.
Źródło:
Chemical and Process Engineering; 2011, 32, 1; 41-55
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concentrations of carbon monoxide and nitrogen oxides from a 25 kW boiler supplied periodically and continuously with wood pellets
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/185416.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pelety
spalanie
emisja
stacja ciepła
coniferous
wood pellets
combustion
emission
heat station
Opis:
The impact of the fuel feeding mode (continuous or periodic with different stand-by/operation time ratios) on carbon monoxide (CO) and nitrogen oxides (NO, NOx) concentration values in the flue gas was analysed for coniferous wood pellet firing. Experiments were performed in a 25 kW water boiler equipped with an over-fed wood pellet furnace located in a full scale heat station simulating real-life conditions. Influence of oxygen concentration and temperature in the combustion chamber on carbon monoxide and nitrogen oxide concentrations was presented in diagrams. Dust and hydrocarbon concentrations were also monitored. It was concluded that the commonly used periodic fuel supply does not necessarily cause a significant increase of carbon monoxide concentration, as compared to the continuous fuel feeding mode. Continuous fuel supply can even induce higher carbon monoxide concentrations when fuel mass stream is not chosen properly. Each time new fuel type is used in a specific furnace, one should perform experiments to determine the adequate settings (stand-by/operation time ratio, fuel mass streams, air stream) to obtain the optimal, lowest possible emission for a certain boiler heat output.
Źródło:
Chemical and Process Engineering; 2014, 35, 2; 163-172
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pollutant emission from a heat station supplied with agriculture biomass and wood pellet mixture
Autorzy:
Juszczak, M.
Lossy, K.
Powiązania:
https://bibliotekanauki.pl/articles/185505.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pozostałości rolnicze
drewno
spalanie
emisja
stacja ciepła
agricultural residue
wood
combustion
emission
heat station
Opis:
Tests for combustion of hay and sunflower husk pellets mixed with wood pellets were performed in a horizontal-feed as well as under-feed (retort) wood pellet furnace installed in boilers with a nominal heat output of 15 and 20 kW, located in a heat station. During the combustion a slagging phenomenon was observed in the furnaces. In order to lower the temperature in the furnace, fuel feeding rate was reduced with unaltered air stream rate. The higher the proportion of wood pellets in the mixture the lower carbon monoxide concentration. The following results of carbon monoxide concentration (in mg/m3 presented for 10% 02 content in flue gas) for different furnaces and fuel mixtures (proportion in wt%) were obtained: horizontal-feed furnace supplied with hay/wood: 0/100 - 326; 30/70 - 157; 50/50 - 301; 100/0 - 3300; horizontal-feed furnace supplied with sunflower husk/wood: 50/50 - 1062; 67/33 - 1721; 100/0 - 3775; under-feed (retort) furnace supplied with hay/wood: 0/100 - 90; 15/85 - 157; 30/70 - 135; 50/50 - 5179; under-feed furnace supplied with sunflower husk/wood: 67/33 - 2498; 100/0 - 3128. Boiler heat output and heat efficiency was low: 7 to 13 kW and about 55%, respectively, for the boiler with horizontal-feed furnace and 9 to 14 kW and 64%, respectively, for the boiler with under-feed furnace.
Źródło:
Chemical and Process Engineering; 2012, 33, 2; 231-242
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correlation between air flow rate and pollutant concentrations during two-stage oak log combustion in a 25 KW residential boiler
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/184902.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wood combustion
pollutant emission
heating boiler
heat station
spalanie drewna
emisja zanieczyszczeń
kocioł grzewczy
stacja ciepła
Opis:
It can be expected that there is a considerable correlation between combustion air flow rate and the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas. The influence of temperature and oxygen concentration in the combustion zone on the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas, for high and low combustion air flow, was analysed. Oxygen concentration for which the concentration of carbon monoxide is the lowest was determined, as well as the mutual relation between carbon monoxide and nitrogen oxide concentration.
Źródło:
Chemical and Process Engineering; 2016, 37, 3; 419-428
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies