Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Jurczyk, K." wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
New proposal concerned with displaying underwater vehicle parameters
Nowe spojrzenie na wizualizację parametrów pojazdów podwodnych
Autorzy:
Jurczyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/955976.pdf
Data publikacji:
2017
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
Remotely Operated Vehicles (ROV)
display of underwater vehicle parameters
pojazdy podwodne typu ROV
wizualizacja parametrów pojazdów podwodnych
Opis:
The article presents a proposal, based on an analysis of the software used for displaying parameters of two underwater vehicles, for extending display applications by using the Lab View environment. The purpose of the solution presented is to uniform data displays transmitted from underwater vehicles, used by operators to operate these vehicles as well as consider the possibility for extending the software offered by producers of vehicles by new elements facilitating evaluation of the vehicle’s condition and the effect of the environment on this condition when the vehicle is being operated.
W artykule, w oparciu o analizę oprogramowania służącego do wizualizacji parametrów dwóch pojazdów podwodnych, omówiona została propozycja rozszerzenia aplikacji wizualizacji poprzez wykorzystanie środowiska LabView. Przedstawione rozwiązanie ma na celu ujednolicenie wyświetlania danych przekazywanych z pojazdów podwodnych wykorzystywanych przez operatorów do sterowania tymi pojazdami, jak również rozpatrzenie możliwości rozszerzenia oprogramowania proponowanego przez producentów pojazdów o nowe elementy, ułatwiające ocenę stanu pojazdu i wpływu środowiska na ten stan w procesie sterowania.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2017, R. 58 nr 2 (209), 2 (209); 61-74
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The prospect for the launche of a mini unmanned aerial vehicle from an unmanned surface vehicle
Perspektywa startu małego bezzałogowego statku powietrznego z bezzałogowego pojazdu nawodnego
Autorzy:
Jurczyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/223127.pdf
Data publikacji:
2018
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
mini unmanned aerial vehicle (mini-UAV)
unmanned surface vessel (USV)
pneumatic launcher
bezzałogowy statek powietrzny (UAV)
bezzałogowy pojazd nawodny (USV)
wyrzutnia pneumatyczna
Opis:
Due to the growing interest in the problems of cooperation among unmanned vehicles, in the article the proposition of the system for launching a mini unmanned aerial vehicle (mini-UAV) from an unmanned surface vehicle (USV) has been presented. The solution differs from the previously used in this that instead of the commonly used rotorcrafts it concerns the ability to start the mini aircraft with the help of pneumatic or rubber launcher. The results of the computer simulation have confirmed the possibility of implementation of that kind of system.
W związku z rosnącym na świecie zainteresowaniem problemami współpracy między pojazdami bezzałogowymi w artykule przedstawiona została propozycja systemu pozwalającego na start małego bezzałogowego statku powietrznego (UAV) z małego bezzałogowego pojazdu nawodnego (USV). Rozwiązanie to różni się od dotychczasowych tym, iż zamiast stosowanych powszechnie wiropłatów rozpatrzono możliwość startu płatowca przy użyciu wyrzutni pneumatycznej lub gumowej wspomagającej start. Wyniki symulacji komputerowej potwierdziły możliwość realizacji takiego systemu.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2018, R. 59 nr 1 (212), 1 (212); 5-26
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of Niti Based Nanocomposites Reinforced by Ha Addition
Autorzy:
Niespodziana, K.
Jurczyk, K.
Jurczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/356601.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomaterial
NiTi
hydroxyapatite
nanocomposite
mechanical alloying
Opis:
NiTi alloy is well known for its unique properties, such as good ductility at room temperature, good corrosion resistance and also thermal shape memory effects. On the other hand hydroxyapatite has a combination of desirable properties, such as low density and excellent compatibility with the bone which used as ceramic reinforced phases can change the properties and thermal stability of the NiTi alloy. In this study, the NiTi alloy matrix shape memory composite reinforced by hydroxyapatite particles was successfully fabricated using mechanical alloying and powder metallurgical process. The structural evaluation of milled and heat treated powders was studied by X-ray diffraction, scanning electron microscopy and transmission electron microscopy. The differential scanning calorimetry was used to measure the phase transformation temperatures. The porosity, Vickers’ hardness and corrosion resistance of the TiNi-HA composites were investigated. The results show that the increase of the weight ratio of hydroxyapatite causes increase the porosity and decrease the corrosion resistance. The fabricated NiTi alloy matrix composite possesses lower density and higher Vickers’ hardness as the pure NiTi shape memory alloy, yet still exhibiting the shape memory effect.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 577-580
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel Ti-based nanocomposites for medical applications
Nanokompozyty tytanowe do zastosowań w medycynie
Autorzy:
Jurczyk, M.
Niespodziana, K.
Jurczyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/211504.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
nanotechnologia
nanokompozyty
tytan
hydroksyapatyt
biokompatybilność
mechaniczna synteza
nanotechnology
nanocomposites
titanium
hydroxyapatite
biocompatibility
mechanical alloying
Opis:
Titanium and titanium alloys possess favorable properties, such as relatively low modulus, low density, high strength. Apart from that, these alloys are generally regarded to have good biocompatibility and high corrosion resistance, but cannot directly bond to the bone. In addition, metal implants may loose and even separate from surrounding tissues during implantation. One of the methods that allow the change of biological properties of Ti alloys is to produce a composite, which will exhibit the favorable mechanical properties of titanium and excellent biocompatibility and bioactivity of ceramic. Recently, at Poznan University of Technology, mechanical alloying method (MA) and powder metallurgy process for the fabrication of novel titanium-ceramic nanocomposites with a unique microstructure has been developed. This process permits the control of microstructural properties such as the size of pore openings, surfaces properties, and the nature of the base metal/alloy. In our work, the structure, mechanical, corrosion properties and biocompatibility of titanium-ceramic nanocomposites were studied. For example, the Ti-HA nanocomposites mainly consist of different apatite or calcium particles, respectively, reinforced with titanium matrix. The existence of Ti can promote decomposition of HA, however no reactions form between HA and Ti. Different phase constitutions have significant influence on the mechanical and corrosion properties of sintered materials. The biocompatibility was investigated studying the behaviour of Normal Human Osteoblast (NHOst) cells, as well. Ti-ceramic nanocomposites posses better mechanical and corrosion properties than microcrystalline titanium. For this reason, they are promising biomaterial for use as medical implants.
Tytan i stopy tytanu charakteryzują szeregiem korzystnych własności takich jak niski moduł sprężystości, mała gęstość, wysoka wytrzymałość. Powszechnie uważa się, że stopy te maja dobrą biokompatybilność i odporność korozyjną lecz nie mogą bezpośrednio łączyć się z kością. Jednakże, implanty metalowe w czasie użytkowania mogą się obluzowywać a nawet oddzielać od otaczającej tkanki. Jedną z metod, pozwalającą na zmianę własności biologicznych stopów tytanu, jest wytwarzanie kompozytów, które będą łączyć korzystne własności wytrzymałościowe tytanu z doskonałą biokompatybilnością i bioaktywnością ceramiki. Ostatnio, w Instytucie Inżynierii Materiałowej Politechniki Poznańskiej opracowano technologię wytwarzania nowych nanokompozytów tytanowo-ceramicznych metodą mechanicznej syntezy i metalurgii proszków. Procesy te umożliwiają kontrolę własności mikrostruktury takich jak wielkość por i własności powierzchni. W niniejszej pracy zbadano własności strukturalne, mechaniczne, korozyjne i biokompatybilność kompozytów tytanowo-ceramicznych. Przykładowo, nanokompozyty typu Ti-HA zbudowane są głównie z cząstek różnego rodzaju apatytów i wapnia rozłożonych w osnowie tytanowej. Obecność tytanu może powodować rozkład HA, jednakże reakcja pomiędzy HA i Ti nie jest obserwowana. Różna budowa fazowa syntetyzowanych materiałów ma znaczący wpływ na ich własności mechaniczne i odporność korozyjną. Zbadano również biokompatybilność kompozytów w hodowli komórek ludzkich osteoblastów. Wytworzone nanokompozyty tytanowo-ceramiczne posiadają lepsze własności mechaniczne i korozyjne w porównaniu do mikrokrystalicznego tytanu. Z tego względu mogą stać się perspektywicznymi biomateriałami do zastosowań na implanty medyczne.
Źródło:
Obróbka Plastyczna Metali; 2008, 19, 4; 37-45
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Malaria: the forgotten threat. A case study of patients hospitalized in the Department of Infectious Diseases and Hepatology at the Pomeranian Medical University Szczecin
Malaria - zapomniane zagrożenie. Analiza przypadków malarii u osób leczonych w Klinice Chorób Zakaźnych i Hepatologii Pomorskiego Uniwersytetu Medycznego w Szczecinie
Autorzy:
Laurans, L.
Niscigorska-Olsen, J.
Socha, L.
Urbanska, A.
Jurczyk, K.
Karpinska, E.
Powiązania:
https://bibliotekanauki.pl/articles/44769.pdf
Data publikacji:
2012
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Opis:
Malaria remains a major health issue In the world, while in Poland no cases of the indigenous disease have been observed since 60-ties of the last century, but the number of cases imported from the epidemic areas is increasing. The aim of work was to analyse the epidemiology of malaria diagnosed and treated in the Department of Infectious Diseases and Hepatology, Pomeranian Medical University, Szczecin, Poland from 1.02.2010 until 31.01.2011. In total 11 cases were found, all diagnoses based on the thick and thin blood smear microscopy, alongside to the standard laboratory analyses.All clinical data presented are based on the case history. Results: Majoriry of cases reported travel to Sub-Saharan Africa (45%) or Indian subcontinent (27%). The travel was usually for recreational purposes, with significant proportion (45%) of patient not taking the malaria prophylaxis. Clinical course of infections was largely mild, with dominance of Pl. Falciparum parasitaemia. Fever was the most common clinical symptom (90%), while in the routine laboratory test no significant abnormalities, suggesting the disease, were found. Conclusions: malaria should be suspected in every case of the returning traveler with fever, especially if the travel was to the endemic area. The exclusion of the disease cannot be based on routine laboratory tests or quick immunoassays – thick and thin blood smear microscopy must be performed.
Malaria ciągle jest głównym problemem zdrowotnym świata, natomiast w Polsce od lat 60. ubiegłego wieku nie stwierdzono rodzimych przypadków malarii. Zwraca jednak uwagę ostatnio rosnąca liczba pacjentów z malarią powracających ze stref epidemicznych. Celem pracy była analiza epidemiologiczna wszystkich przypadków potwierdzonej malarii leczonych w Katedrze i Klinice Chorób Zakaźnych PUM w Szczecinie w okresie między 1.02.2010 a 31.01.2011 r. Do analizy zakwalifikowano 11 przypadków malarii hospitalizowanych w Oddziale Chorób Zakaźnych i Hepatologii. U wszystkich rozpoznanie tej parazytozy oparto na badaniu grubej kropli i cienkiego rozmazu, dodatkowo u wszystkich wykonano rutynową diagnostykę laboratoryjną. Dodatkowe informacje uzyskano na podstawie poszerzonego wywiadu lekarskiego. Wyniki: najczęściej pacjenci z malarią powracali z Afryki Subsaharyjskiej (45%) bądź z Półwyspu Indyjskiego (27%). Większość osób wyjeżdżała w celach turystycznych, a znamienna większość nie przyjmowała chemoprofilaktyki przeciwmalarycznej. Wśród analizowanych pacjentów, poza jednym przypadkiem, dominowały łagodne postaci malarii, głównie gatunek Pl. falciparum. Prawie u wszystkich osób występowała gorączka (90%), natomiast w rutynowych badaniach dodatkowych nie wykazano odchyleń uznanych za wykładniki tej choroby. Wnioski: malarię należy podejrzewać u każdego chorego powracającego z rejonu epidemicznego, zwłaszcza, jeżeli występuje gorączka. Nie można wykluczyć tej choroby na badaniach rutynowych czy szybkich testach immunoenzymatycznych, a jedynie na podstawie grubej kropli i cienkiego rozmazu.
Źródło:
Acta Scientiarum Polonorum. Zootechnica; 2012, 11, 1
1644-0714
Pojawia się w:
Acta Scientiarum Polonorum. Zootechnica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies