Tytuł:
Time-integrated diagnostics of X-ray emission from PALS and PF 1000 : preliminary results
Autorzy:
Ryć, L.
Krása, J.
Juha, L.
Kaczmarczyk, J.
Paduch, M.
Parys, P.
Tomaszewski, K.
Scholz, M.
Powiązania:
https://bibliotekanauki.pl/articles/148024.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
high-temperature plasma
semiconductor detector
thermoluminescent detector
X-ray diagnostics
Opis:
Thermoluminescent and semiconductor detectors operating in an integrating mode have been applied to the measurement of X-ray flashes of high intensity from large plasma facilities. A detection head of special kind has been developed to perform comparison measurements with the use of the detectors of both kinds.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 41-43
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy transformation in Plasma Focus discharge with wire and liner as a load
Autorzy:
Kubeš, P.
Kravárik, J.
Klír, D.
Scholz, M.
Paduch, M.
Tomaszewski, K.
Karpinski, L.
Ryc, L.
Juha, L.
Krasa, J.
Szydlowski, A.
Romanova, V.
Powiązania:
https://bibliotekanauki.pl/articles/147107.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray source
XUV spectroscopy
Opis:
We present the results of experiments focused on energy transformations during the implosion of the hydrogen current sheath towards an Al wire (120 ěm in diameter) positioned on the top of the inner electrode of the PF-1000 plasma focus facility at the IPPLM in Warsaw. A wire corona is formed at the current sheath impact and ~60 ns after the impact a soft X-ray pulse is emitted. Its spectrum contains AlVI-XII lines accompanied by their satellites. The amount of emitted energy is recorded by two filtered PIN diodes and thermoluminescent dosimeters and depends on symmetry of the current sheath and quality of the current sheath focus. The mean value of energy of keV photons emitted in the runs done without the wire (~1 J) is higher than the energy obtained with the wire (~0.4 J). A time delay between the impact of the current sheath and X-ray pulse, the plasma focus dynamics and soft X-ray emission are interpreted by an axial magnetic field generation and transformations.
Źródło:
Nukleonika; 2002, 47, 4; 151-153
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies