Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "auxetic" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
An analysis of the auxetic cranioplasty implant
Autorzy:
Maciejewska, Jagoda
Jopek, Hubert
Powiązania:
https://bibliotekanauki.pl/articles/2146601.pdf
Data publikacji:
2020
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
auxetic structures
cranioplasty
skull implant
finite elements method
struktury auksetyczne
kranioplastyka
implant czaszkowy
metoda elementów skończonych
Opis:
The following paper is a reflection on the advisability of using auxetic structures in medical devices. For this purpose, a model of a skull implant was designed. This implant could be used for cranioplasty of bone defects after neurosurgical procedures. The implant is made of a titanium alloy and has an auxetic "double arrow" structure. The behavior of the implant was investigated in two cases, under the influence of increased intracranial pressure and impact of an external force. The calculations were made with the finite element method implemented in the SolidWorks 2020 program. Moreover, the natural frequency of the structure was examined in the Comsol Multiphysics program.
Źródło:
Vibrations in Physical Systems; 2020, 31, 3; art. no. 2020315
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of the lower limb prosthesis subjected to various load conditions
Autorzy:
Kowalczyk, Milena
Jopek, Hubert
Powiązania:
https://bibliotekanauki.pl/articles/2146610.pdf
Data publikacji:
2020
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
prosthetic sockets
FEM analysis
auxetic
negative Poisson’s ratio
leje protezowe
analiza MES
auksetyk
ujemny współczynnik Poissona
Opis:
This article presents the simulation of a prosthetic socket with an auxetic structure under typical loading cases. The designed model of prosthetic socket is dedicated to patients who have undergone transfemoral amputation and consists of four elements, among which can be distinguished an inner lining, a shock absorbing element, component with a honeycomb re-entrant structure, which has a negative Poisson's ratio an outer shell. The prosthetic socket was analysed by means of the finite element method. The simulations were used to evaluate the strength of the design and to check whether it is possible to avoid a problem of changing the circumference of the patient's stump, thanks to the use of an auxetic structure in the socket.
Źródło:
Vibrations in Physical Systems; 2020, 31, 3; art. no. 2020309
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies