Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Jasinska, M." wg kryterium: Autor


Tytuł:
Investigations of Resorcinol under High Pressure
Autorzy:
Tydda, M.
Jasińska, B.
Powiązania:
https://bibliotekanauki.pl/articles/1196480.pdf
Data publikacji:
2014-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.70.Bj
36.10.Dr
61.66.Hq
Opis:
The investigation of intermolecular free volumes in resorcinol was conducted under high pressure, hydraulic pressure and gas (argon or nitrogen) atmosphere. The sizes of free volumes were estimated basing on the mean lifetime of ortho-positronium (o-Ps). In the first case, a monotonous change of lifetime and intensity was observed for the o-Ps component while the range of pressure was 0-477 MPa. On the other case, the samples were put into the pressure chamber filled with argon or nitrogen in the range of pressure from 0 to 450 MPa. When the pressure chamber was filled with a gas, the appearance of an additional o-Ps component has been found. In the nitrogen atmosphere, the material crushed when the gas pressure reached about 200 MPa, and the mean lifetime of the longest o-Ps component increased.
Źródło:
Acta Physica Polonica A; 2014, 125, 3; 812-815
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Redistribution of o-Ps in Porous Vycor Glass. Crystallization of Silica at High Temperatures
Autorzy:
Śniegocka, M.
Jasińska, B.
Powiązania:
https://bibliotekanauki.pl/articles/2047163.pdf
Data publikacji:
2006-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.70.Bj
71.60.+z
Opis:
The positron annihilation lifetime spectroscopy was applied to study the porous Vycor glass annealed at the temperatures between 950 and 1050 K. With increased temperature the spectra show significant decrease in o-Ps lifetime and intensity in the pores, while the rise of intensity in the small intermolecular voids is observed. Similar changes are observed as a function of annealing time at fixed temperature depending on the time and temperature of thermal treatment. They can originate from partial crystallization of the silica in the material under study.
Źródło:
Acta Physica Polonica A; 2006, 110, 5; 721-727
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of the free volume sizes and shapes determined from crystallographic and PALS data
Autorzy:
Tydda, M.
Jasińska, B.
Powiązania:
https://bibliotekanauki.pl/articles/146378.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
benzenediols
free volume
molecular crystals olanzapine
positron annihilation
positronium
positronium diffusion coefficient
Opis:
Two different classes of molecular crystals were investigated. The first group was benzenediols, which are characterized by the same chemical composition but a different organization of their crystallographic structures; all of the compounds from this group have only one kind of free volumes. The second class was represented by olanzapine, which has more complex chemical composition and two kinds of free volumes in the structure. The o-Ps lifetime values determined from positron annihilation lifetime spectroscopy (PALS) measurements agree quite well with those calculated for sizes found from crystallographic data for benzenediols (agreement within 10% of the lifetime values). For olanzapine, a good agreement is observed in the case of cuboidal free volumes, while for the other kind of void, the agreement is less satisfactory. Positronium diffusion coefficient determined from o-Ps redistribution in olanzapine agrees with these found for polymers.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 771-775
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PALS investigation of resorcinol under high pressure
Autorzy:
Tydda, M.
Jasińska, B.
Pieniążek, A.
Powiązania:
https://bibliotekanauki.pl/articles/147999.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
free volume
ortho-positronium (o-Ps)
pressure
positron annihilation lifetime spectroscopy (PALS)
Opis:
Two kinds of measurements were conducted with resorcinol at high pressure : the first one with the use of a mechanical press and the second one with the use of a gaseous compressor. In the second case, due to some gas penetrating the material structure, the lifetime spectra obtained were difficult to analyze. The free volumes in resorcinol were influenced both by high pressure and the gas coming into the crystallographic structure.
Źródło:
Nukleonika; 2013, 58, 1; 195-198
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PALS investigations of matrix Vycor glass doped with molecules of luminescent dye and silver nanoparticles. Discrepancies from the ETE model
Autorzy:
Gorgol, M.
Jasińska, B.
Reisfeld, R.
Powiązania:
https://bibliotekanauki.pl/articles/147152.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
positron annihilation lifetime spectroscopy (PALS)
porous glass
lumogen dye ROT-305
silver nanoparticles
Vycor glass
Opis:
A thermal stability of three materials: undoped reference Vycor glass, glass filled with ROT-305 red dye, and silver nanoparticles was investigated by positron annihilation lifetime spectroscopy (PALS) in a broad temperature range (from 93 to 473 K). The attempt of pore size calculations from the ortho-positronium lifetime data was performed using the extended Tao-Eldrup (ETE) model. Below room temperature, a significant decrease in lifetime values of the longest-lived component was found for all the samples. This effect could not be explained by thermal shrinkage of the material and is probably caused by interaction of -Ps with a Vycor glass matrix. The greatest discrepancy from the ETE model predictions was observed for the reference glass. Doping the base material with dye molecules and silver nanoparticles resulted in similar small decrease in this discrepancy. After reheating the samples to the room temperature, the PALS components returned to the initial values. In the temperature range of 293–473 K, quite good agreement between PALS results and the ETE model predictions was observed for the reference glass and the glass incorporated with dye molecules. The observed small discrepancy in this range could possibly be partly explained by thermal expansion of the material. For the glass doped with silver nanoparticles, a significant change in PALS parameters was observed in the temperature range from 403 to 473 K.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 717-720
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porosity structure in photon active glasses
Autorzy:
Jasińska, B.
Śniegocka, M.
Reisfeld, R.
Zigansky, E.
Powiązania:
https://bibliotekanauki.pl/articles/147953.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
glass
ortho-positronium (o-Ps)
porosity
positron annihilation lifetime spectroscopy (PALS)
sol-gel technique
Opis:
Two kinds of photon active glasses were investigated using positron annihilation lifetime spectroscopy (PALS). Both kinds of glasses were prepared using a sol-gel technique, doped by complex of ruthenium tris bipyridyl chloride. Glasses differed from the initial matrix: the first one was prepared using silicon oxide while the second one - zircon oxide. The ortho-positronium (o-Ps) lifetime and intensities were determined from lifetime spectra. Different porosity structure concluded from PALS measurements was found in both cases. In the silica based glasses small free volumes (angstrom size) and pores (from 1 to 10 nm) existed in the material. On the contrary, in zirconia based glasses small intermolecular voids were produced in the structure only, independently of the way of material preparation.
Źródło:
Nukleonika; 2013, 58, 1; 241-244
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of the Temperature on Positron Annihilation Lifetime Spectra in Porous Sol-Gel Glass Doped with Ag Nanoparticles
Autorzy:
Gorgol, M.
Jasińska, B.
Reisfeld, R.
Levchenko, V.
Powiązania:
https://bibliotekanauki.pl/articles/1196126.pdf
Data publikacji:
2014-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.70.Bj
36.10.Dr
65.60.+a
61.43.Gt
Opis:
Silver nanoparticles with continuous size distribution from 10 to 20 nm were incorporated into porous glass produced using sol-gel technique. Positron annihilation lifetime spectroscopy was used to compare obtained material with an undoped reference glass. The positron annihilation lifetime spectroscopy measurement were made in a broad temperature range (from - 180C to 200°C). The experimental lifetime values were compared with the predictions of the extended Tao-Eldrup model of the temperature range. Experimental results for the reference material were in agreement with the model, except for a small discrepancy at low temperatures. In doped material substantial changes and non-monotonous temperature dependences of intensity and lifetime values were observed. Heating the material to 200C resulted in reorganization of the material structure.
Źródło:
Acta Physica Polonica A; 2014, 125, 3; 778-781
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing the Extended Tao-Eldrup Model. Silica Gels Produced with Polymer Template
Autorzy:
Śniegocka, M.
Jasińska, B.
Wawryszczuk, J.
Zaleski, R.
Deryło-Marczewska, A.
Skrzypek, I.
Powiązania:
https://bibliotekanauki.pl/articles/2043364.pdf
Data publikacji:
2005-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.70.Bj
61.43.Gt
Opis:
The temperature dependence of o-Ps lifetime in the pores calculated from extended Tao-Eldrup model was compared to the experimental data, collected for a set of silica gels synthesized using the polymer template technique. For the sample with average pore radii 2.0 nm rather good agreement between the model and experiment was found. For the sample with narrow pores (near 1.0 nm) the lifetime spectrum was complex. Except the range of highest temperatures the lifetimes are far from model calculations.
Źródło:
Acta Physica Polonica A; 2005, 107, 5; 868-873
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Autorzy:
Sharma, N. G.
Silarski, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/146937.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
J-PET detector
Mahalanobis distance
time resolution
threshold levels
Opis:
The J-PET detector being developed at the Jagiellonian University is a positron emission tomograph composed of the long strips of polymer scintillators. At the same time, it is a detector system that will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit time and hit position of the gamma quantum. In order to take advantage of this fact, a dedicated sampling front-end electronics that enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity, we use the Mahalanobis distance. The achievable position and time resolution depend on the number and values of the threshold levels at which the signal is sampled. A reconstruction method as well as preliminary results are presented and discussed.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 765-769
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Method to Produce Linearly Polarized Positrons and Positronium Atoms with the J-PET Detector
Autorzy:
Mohammed, Muhsin
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, ---
Skurzok, M.
Silarski, M.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1030045.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.75.Fr
41.75.Ht
77.22.Ej
36.10.Dr
85.75.Mm
87.57.uk
Opis:
A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1486-1489
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Human tissue investigations using PALS technique - free radicals influence
Autorzy:
Jasińska, B.
Zgardzińska, B.
Chołubek, G.
Pietrow, M.
Gorgol, M.
Wiktor, K.
Wysogląd, K.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Hiesmayr, B.
Jodłowska-Jędrych, B.
Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiktor, H.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057941.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
positron annihilation
positronium
free radicals
tissues
uterine leiomyomas
Opis:
The positron annihilation lifetime spectroscopy was applied to the samples of the human uterine leiomyomas and the normal myometrium tissues taken from the selected place of the uterus during a surgery. The method indicated differences in values of the measured positron annihilation lifetime spectroscopy parameters (lifetimes and intensities) between healthy and diseased tissue samples. The additional measurements were performed either in darkness or in presence of visible light which influenced the free radicals present in both kind of tissues and, as a result, made changes in free annihilation and o-Ps decay lifetime and intensity values.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1556-1558
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Processing optimization with parallel computing for the J-PET scanner
Autorzy:
Krzemień, W.
Bała, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Stola, K.
Strzelecki, A.
Trybek, D.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/148285.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
data aquisition system (DAQ)
parallel computing
TOF-PET
Opis:
The Jagiellonian Positron Emission Tomograph (J-PET) collaboration is developing a prototype time of flight (TOF)-positron emission tomograph (PET) detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast fi eld programmable gate array (FPGA)-based front-end electronics and the data acquisition system, as well as low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in the case of a large acceptance detector that works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 745-748
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time Calibration of the J-PET Detector
Autorzy:
Skurzok, M.
Silarski, M.
Alfs, D.
Białas, P.
Shivani, S.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033283.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.fb
36.10.Dr
11.30.Er
24.80.+y
Opis:
The Jagiellonian positron emission tomograph project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time-and high angular resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a ²²Na source and a small detector providing common reference time for synchronization of all the modules.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1641-1644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
Autorzy:
Kamińska, D.
Gajos, A.
Czerwiński, E.
Bednarski, T.
Białas, P.
Gorgol, M.
Jasińska, B.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/147408.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
discrete symmetries
J-PET
ortho-positronium
Opis:
In this paper, we present prospects for using the Jagiellonian positron emission tomograph (J-PET) detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the standard model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10−3. The J-PET detector allows to determine those values with better precision, thanks to the unique time and angular resolution combined with a high geometrical acceptance. Achieving the aforementioned is possible because of the application of polymer scintillators instead of crystals as detectors of annihilation quanta.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 729-732
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies