Tytuł:
Monte Carlo modeling of electron beams from a NEPTUN 10PC medical linear accelerator
Autorzy:
Jabbari, N.
Hashemi-Malayeri, B.
Powiązania:
https://bibliotekanauki.pl/articles/148140.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Monte Carlo
radiotherapy
electron beams
linac
Opis:
The Monte Carlo (MC) simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. With the rapid development of computer technology, MC-based treatment planning for radiation therapy is becoming practical. A basic requirement for MC treatment planning is a detailed knowledge of radiation beams of medical linear accelerators (linacs). A practical approach to acquire this knowledge is to perform MC simulation of radiation transport for linacs. The aims of this study were: modeling of the electron beams from the NEPTUN 10PC linear accelerator (linac) with the MC method, obtaining of the energy spectra of electron beams, and providing the phase-space files for the electron beams of this linac at different field sizes. Electron beams produced by the linac were modeled using the BEAMnrc MC system. Central axis depth-dose curves and dose profiles of the electron beams were measured experimentally and also calculated with the MC system for different field sizes and energies. In order to benchmark the simulated models, the percent depth dose (PDD) and dose-profile curves calculated with the MC system were compared with those measured experimentally with diode detectors in an RFA 300 water phantom. The results of this study showed that the PDD and dose-profile curves calculated by the MC system using the phase-space data files matched well with the measured values. This study demonstrates that the MC phase-space data files can be used to generate accurate MC dose distributions for electron beams from NEPTUN 10PC medical linac.
Źródło:
Nukleonika; 2009, 54, 4; 233-238
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies