Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Jóźwiakowski, P." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Correlations between organic pollution indicators in municipal wastewater
Korelacje pomiędzy wskaźnikami zanieczyszczeń organicznych w ściekach komunalnych
Autorzy:
Siwiec, T.
Reczek, L.
Michel, M. M.
Gut, B.
Hawer-Strojek, P.
Czajkowska, J.
Jóźwiakowski, K.
Gajewska, M.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/205468.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
BOD5
CODCr
TOC
CODMn
wastewater
municipal wastewater treatment plant
BZT5
ścieki
miejska oczyszczalnia ścieków
Opis:
The paper presents the results of a study of parameters used for determining the amount of organic pollutants in wastewater flowing into a collective wastewater treatment plant with a population equivalent of about 120 000 PE. The plant constituted part of a sewage system. Assays were performed for biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), permanganete index (CODMn) and total organic carbon (TOC). In addition, the pH of wastewater and its alkalinity were determined. Sampling of incoming wastewater and measurement of physicochemical parameters were performed once a week, in the spring. A total of 44 samples of wastewater were collected. The correlations between the individual parameters and the correlations between the ratios of these parameters were determined. It was found that it was possible to estimate, with sufficient accuracy, the values of selected parameters for determining the concentrations of organic compounds in municipal wastewater, knowing the values of other parameters in this group. Moreover, it was shown that, knowing the relationship between the analyzed parameters, one can find multiple regression equations for a given type of wastewater, which allow one to calculate the remaining relationships with a good fi t, i.e. a determination factor R2 greater than 0.6.
W pracy przedstawiono wyniki badań parametrów wykorzystywanych do oznaczania ilości zanieczyszczeń organicznych w ściekach wpływających do zbiorczej oczyszczalni ścieków o równoważnej liczbie ludności około 120 000 mieszkańców. Zakład stanowi część systemu kanalizacyjnego. Testy przeprowadzono dla biochemicznego zapotrzebowania na tlen (BZT5), chemicznego zapotrzebowania na tlen (CODCr), utlenialności (CODMn) i ogólnego węgla organicznego (TOC). Ponadto określono wartość pH ścieków i ich zasadowość. Pobieranie próbek dopływających ścieków i pomiar parametrów fizykochemicznych przeprowadzano raz w tygodniu, na wiosnę. Zebrano łącznie 44 próbki ścieków. Określono korelacje między poszczególnymi parametrami i korelacje między stosunkami tych parametrów. Stwierdzono, że możliwe było oszacowanie, z wystarczającą dokładnością, wartości wybranych parametrów do oznaczania stężeń związków organicznych w ściekach komunalnych, znając wartości innych parametrów w tej grupie. Ponadto wykazano, że znając zależność między analizowanymi parametrami, można znaleźć równania regresji wielokrotnej dla danego typu ścieków, które pozwalają obliczyć pozostałe zależności przy dobrym dopasowaniu, o współczynniku determinacji R2 większym niż 0,6.
Źródło:
Archives of Environmental Protection; 2018, 44, 4; 50-57
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The State of Water and Wastewater Management in the Municipalities of the Polesie National Park
Autorzy:
Jóźwiakowski, K.
Podbrożna, D.
Kopczacka, K.
Marzec, M.
Kowalczyk-Juśko, A.
Pochwatka, P.
Listosz, A.
Malik, A.
Powiązania:
https://bibliotekanauki.pl/articles/123070.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipality
water supply
sewerage
wastewater treatment plant
septic tank
national park
Opis:
The aim of the work is to present the current state of water and wastewater management in the municipalities where the Polesie National Park (PNP) is located. The PNP is situated in Lublin Voivodeship, in the area of six municipalities: Sosnowica, Hańsk, Urszulin, Stary Brus, Wierzbica and Ludwin. The data used in this paper, were obtained on the basis of the surveys conducted in these municipalities in 2016 by the Department of Environmental Engineering and Geodesy of the University of Life Sciences in Lublin. In the analyzed communes, there was a very large disproportion between the usage of sewerage and the water supply network. It has been shown that 79.1% of the inhabitants living in the afore-mentioned communes used the water supply network and only 22.5% of them used sewerage. In the discussed communities there are 9 collective, mechanical and biological wastewater treatment plants with a capacity of over 5 m3•d-1. On the farms located in the scattered areas, which are not connected to the sewerage, wastewater is discharged mainly to the septic tanks. In four out of the six analyzed municipalities, there were 2345 septic tanks registered. Domestic sewage from some farms is purified in household wastewater treatment plants (395 pieces). The plants with the drainage systems are prevalent (84.9%), which may contribute to the groundwater quality degradation. In order to protect the natural environment within the communes that form the PNP, it is necessary to undertake the actions that will contribute to the improvement of the current state of water and wastewater management. While solving the existing problems related to water supply and wastewater treatment, it is strongly required to adhere to the principle of sustainable development and use highly effective systems in order to ensure that the ecological effects are appropriate.
Źródło:
Journal of Ecological Engineering; 2017, 18, 6; 192-199
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The State of Water and Wastewater Management in the Municipalities of the Roztocze National Park
Autorzy:
Jóźwiakowski, K.
Podbrożna, D.
Kopczacka, K.
Jaguś, M.
Marzec, M.
Listosz, A.
Pochwatka, P.
Kowalczyk-Juśko, A.
Malik, A.
Powiązania:
https://bibliotekanauki.pl/articles/123660.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipality
water supply
sewage system
sewage treatment plant
septic tank
national park
Opis:
The aim of this paper is to present the current state of water and sewage management in the communes where the Roztocze National Park (RNP) is located. The park is located in Lubelskie voivodship, in the territory of four communes: Zamość, Zwierzyniec, Adamów and Józefów, while its buffer zone is located in the communes of Krasnobród, Tereszpol and Szczebrzeszyn. The paper uses data from surveys conducted in these municipalities in 2016. On average, 68.9% of the population used the water supply system in the municipalities surveyed, while 33.4% of the inhabitants had the possibility of discharging sewage to the sewerage system. In the area of the communes, there are 10 collective, mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3·d-1. The households which are not connected to the sewage network discharge wastewater mainly to non-return tanks. Four out of the seven surveyed communities had 64 domestic sewage treatment plants, including 60 systems with infiltration drainage, which do not ensure high efficiency of removing pollution and may even contribute to the degradation of groundwater quality. In order to solve the existing problems in the area of sewage and water management occurring in the communes where the Roztocze National Park is located, it is necessary to further develop collective sewage systems and equip the areas with dispersed buildings with highly efficient, residential sewage treatment plants, e.g. constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 255-262
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies