Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "85.75.Ss" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Crack Detection Using Fluxgate Magnetic Field Sensor
Autorzy:
Izgi, T.
Goktepe, M.
Bayri, N.
Kolat, V.
Atalay, S.
Powiązania:
https://bibliotekanauki.pl/articles/1207662.pdf
Data publikacji:
2014-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
85.75.Ss
46.50.+a
75.50.Kj
Opis:
In this study, the variation of the magnetic flux distribution in a magnetised ferromagnetic material which has in homogeneity as a crack is studied. An orthogonal fluxgate magnetic field sensor was used in the inspection of cracks. In the fluxgate sensor, the sensing element $(Co_{0.94}Fe_{0.06})_{72.5}Si_{12.5}B_{15}$ amorphous ferromagnetic wire was placed inside a pickup coil winding with 50 μm copper wire and connected to a signal generator and the output from pick-up coil was detected using a lock-in amplifier. The surface profile of magnetic materials with a crack was obtained using a specially designed 3-dimensional moving system. A large decrease in the output voltage of the sensor was observed when the sensor was moved on the top of the crack, after the further movement of the sensor the output voltage came back to the previous value.
Źródło:
Acta Physica Polonica A; 2014, 125, 2; 211-213
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
YIG Film for Magnetic Field Sensor
Autorzy:
Kaya, A.
Atalay, S.
Gencer, H.
Kaya, O.
Kolat, V.
Izgi, T.
Powiązania:
https://bibliotekanauki.pl/articles/1401218.pdf
Data publikacji:
2015-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.15.Gh
84.40.Az
75.30.Ds
41.20.Jb
85.75.Ss
Opis:
Single crystal $Y_3Fe_5O_{12}$ (YIG) film was grown onto (111) oriented gadolinium gallium garnet (GGG) substrate by the liquid phase epitaxy (PLD) technique. The X-ray diffraction measurements showed that epitaxial growth of the film along its (111) axis. The surface characteristic was investigated by atomic force microscopy (AFM) measurement. The magnetic field sensor consisted of a rectangular shape with 5 mm wide, 15 mm long and 5 μm thick YIG film and a pair of identical 50 μm wide microstrip copper transducers elements separated by 6 mm. The filter was tested by measuring reflection $S_{11}$ characteristic at various bias magnetic fields. The results have showed that when the bias field increased from 0 to 2.5 kOe, the frequency value corresponding to $S_{11}$ maxima increased from 1 GHz to 9 GHz. This suggests that the wide range magnetic field sensing and the highly sensitive field sensing are simultaneously fulfilled with the YIG film.
Źródło:
Acta Physica Polonica A; 2015, 127, 4; 937-939
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies