Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "micro-CHP" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Experimental investigation on a rotodynamic pump operating in the cogeneration system with a low-boiling working medium
Autorzy:
Kaczmarczyk, T.
Żywica, G.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/175328.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic rankine cycle
micro-CHP
rotodynamic peripheral pump
low-boiling medium
HFE7100
Opis:
The article presents the research carried out on the circulating rotodynamic pump (peripheral pump) operating in the organic Rankine cycle with or without regeneration. The low-boiling solvent HFE7100 was used as the working fluid. Its boiling point is around 61 ◦C at atmospheric pressure. An expansion valve, which simulated the operation of an expansion machine, was used to load the tested pump. The flow characteristics were given for the working media: a solution of glycol and HFE7100 in the condenser, thermal oil and HFE7100 in the evaporator and HFE7100 in the regenerator. The research results concerning the PK70 pump operating in an ORC cycle are reported for the HFE7100 temperature range 15-60 ◦C and the dynamic viscosity range of 0.132 to 0.66 mPas. The maximum flow rate and pressure of the pump during its operation in the ORC system were assessed. The analysis of the results demonstrates that the maximum efficiencies of the pump operating with or without regeneration were 44% and slightly below 37%, respectively. The impact of the selected physicochemical parameters of the working mediums on the pressure drops occurring in the ORC cogeneration installation was discussed. Based on the research conducted and the measurement results, the possibility to apply a PK70 unit as a circulating pump for the working medium in an ORC cycle was checked.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 134; 63-87
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The theoretical model of the transient behaviour for the micro combined heat and power organic Rankine cycle
Teoretyczny model ciągły dla obiegu kogeneracyjnego ORC
Autorzy:
Matysko, R.
Mikielewicz, J.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/172873.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
układ mikro CHP
obieg ORC
modelowanie dynamiczne
wymiana ciepła
micro CHP system
ORC cycle
dynamical modelling
heat transfer
Opis:
W pracy przedstawiono wyniki obliczeń obiegu ORC w warunkach eksploatacyjnych. Przeprowadzone obliczenia umożliwiają określenie bezwładności układu podczas zmiany obciążeń cieplnych parownika i skraplacza. Z obliczeń uzyskano czasy bezwładności oraz parametry temperatury na dolocie do turbiny i skraplacza dla czynnika R123. Bardzo zbliżone wyniki obliczeń parametrów uzyskanych z własnego modelu obiegu ORC do przeprowadzonego niezależnie eksperymentu dają podstawy do stwierdzenia, że model dobrze odzwierciedla układy rzeczywiste. Podkreślić należy fakt, że obliczenia dynamiki obiegu za pomocą tego modelu przeprowadzono dla różnych czynników roboczych (R123, HFE7100, propan) uzyskując dobre jakościowo wyniki, co pozwala poszerzyć zakres jego stosowalności również na inne czynniki robocze. Wyniki własnych obliczeń porównano z badaniami eksperymentalnymi obiegu ORC innych autorów uzyskując dobrą zgodność.
This article presents results of calculations of the organic Rankine cycle (ORC) in working conditions. The calculations make it possible to define the inertia of the evaporator and condenser while the heat loads change occurs. Calculations allow to get the inertia of the system, and the parameters of temperature at the inlet to the turbine and condenser for the R123 refrigerant. Very similar calculations results of the parameters were obtained from own model for ORC cycle, and experiment results performed independently gave basis to conclude that the model well reflects the real systems. It should be emphasized that the dynamics calculations for the cycle prepared by this model was conducted for different working fluids (R123, HFE7100, propane). Good quality of the results from these calculations, allows to expand the scope of the model applicability to other working fluids. Our own results of calculations were compared with other authors experimental studies of the ORC cycle obtaining a good compliance.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 93-102
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes of the thermodynamic parameters in failure conditions of the micro-CHP cycle
Autorzy:
Matysko, R.
Mikielewicz, J.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/239967.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
micro-CHP system
transient model
failure states
multifuel boiler system
heating system
układ mikro CHP
model przejściowy
stan awaryjny
kocioł
system ogrzewania
Opis:
The paper presents the calculations for the failure conditions of the ORC (organic Rankine cycle) cycle in the electrical power system. It analyses the possible reasons of breakdown, such as the electrical power loss or the automatic safety valve failure. The micro-CHP (combined heat and power) system should have maintenance-free configuration, which means that the user does not have to be acquainted with all the details of the ORC system operation. However, the system should always be equipped with the safety control systems allowing for the immediate turn off of the ORC cycle in case of any failure. In case of emergency, the control system should take over the safety tasks and protect the micro-CHP system from damaging. Although, the control systems are able to respond quickly to the CHP system equipped with the inertial systems, the negative effects of failure are unavoidable and always remain for some time. Moreover, the paper presents the results of calculations determining the inertia for the micro-CHP system of the circulating ORC pump, heat removal pump (cooling condenser) and the heat supply pump in failure conditions.
Źródło:
Archives of Thermodynamics; 2014, 35, 1; 43-59
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies