Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kupka, A. M." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
Simultaneous recording and analysis of direct and indirect fetal electrocardiography
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333338.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG płodu
monitorowanie płodu
fetal electrocardiography
fetal monitoring
Opis:
Recording and analysis of fetal heart rate variability is still the most common method for detection of early symptoms of fetal hypoxia. However, fetal heart rate obtained via ultrasound describes only mechanical activity of fetus heart. Limitations of this technique have stimulated the development of fetal electrocardiography. It ensures more precise determination of fetal heart rate and, which is more important, enables assessment of the morphology of the fetal QRS complexes. In this paper two techniques of obtaining the fetal electrocardiogram are described and their comparative study is presented.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 8; MM111-118
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indexing biomedical streams in data management system
Autorzy:
Widera, M.
Wróbel, J.
Matonia, A.
Jeżewski, M.
Horoba, K.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/333832.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
scentralizowane monitorowanie
przetwarzanie strumienia danych
indeksowanie
centralized monitoring
data stream processing
indexing
Opis:
We are developing Data Stream Management System that can be applied in medical monitoring system. One of the problems is how to support efficient data access methods. This paper considers indexing issues in data management system. The indexing is a commonly used method of data access acceleration. Classical and new streaming methods of indexing have been presented. The method was developed in data stream management system and first applied in a centralized neonatal monitoring system.
Źródło:
Journal of Medical Informatics & Technologies; 2005, 9; 107-112
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of FHR series recorded via ultrasound - method validation using abdominal fetal electrocardiography
Autorzy:
Kupka, T.
Horoba, K.
Roj, D.
Matonia, A.
Czabanski, R.
Jezewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/333726.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal heart rate variability
time event series
sampled signal
duplicated sample
zmienność rytmu serca płodu
sygnał próbny
powielona próbka
Opis:
Analysis of variability of the fetal heart rate (FHR) is very important for fetal wellbeing assessment. The beat-to-beat variability is described quantitatively by the indices originated from invasive fetal electrocardiography which provides the FHR signal in a form of time event series. Nowadays, monitoring instrumentation is based on Doppler ultrasound technology. The fetal monitors provide the output signal in a form of evenly spaced measurements. The goal of this work is to present a new method for the FHR signal processing, which enables extraction of time series of consecutive heartbeat intervals from the evenly repeated values. The proposed correction algorithm enables recognition and removal of the duplicated measurements. Reliable evaluation of the algorithm requires the reference event series, thus the FHR signals were obtained from abdominal fetal electrocardiograms to be used in this research study.
Źródło:
Journal of Medical Informatics & Technologies; 2013, 22; 135-141
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neonatal surveillance system based on data stream technology
Autorzy:
Widera, M.
Matonia, A.
Wróbel, J.
Jeżewski, J.
Horoba, K.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/333868.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie
pulsoksymetr
strumienie
monitoring
pulse oxymetry
streams
Opis:
Pulse oximetry is a non-invasive measurement method of an arterial blood oxygen saturation. Pulse oximeter is one of the main bedside monitors used in neonatal units. The dispersed location of medical devices in such unit renders impossible to make a fast and valid decision in the case of simultaneous alarming situation. This paper present hardware and software structure of centralised neonatal monitoring system. Presented system can work as a single central station for monitoring of up to twenty four patients. Application of central monitoring system decreases the risk of undetected patients live and health threats. Thanks to this system the medical stuff is less burdened by routine procedures; therefore the medical unit is perceived as child- and mother-friendly.
Źródło:
Journal of Medical Informatics & Technologies; 2005, 9; 93-98
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability and quality of ultrasound measurements of fetal heart rate variability
Autorzy:
Jeżewski, J.
Wróbel, J.
Kupka, T.
Matonia, A.
Horoba, K.
Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/334011.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
zmienność tętna płodu
USG metodą Dopplera
EKG płodu
fetal heart rate variability
Doppler ultrasound method
fetal electrocardiogram
Opis:
This work was aimed at assessment of usability of Doppler ultrasound method for the analysis of fetal heart rate variability at a level of single heart beats. The purpose of this study was to check if today fetal monitors provide the signal of accuracy comparable with an electrocardiography method. The virtual instrumentation software for measurement system and processing of acquired signals was implemented using LABVIEW environment. The results obtained reveal that accuracy of today monitors which use Doppler ultrasound technique is sufficient for visual analysis of the FHR traces. However, for the computerized analysis at a beat-to-beat level, this accuracy is below the acceptable value.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT21-26
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined analysis of fetal electrocardiogram and systolic time intervals
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Wróbel, J.
Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/334019.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
wybrany termin cyklu sercowego
EKG płodu
tętno płodu
fetal monitoring
cardiac cycle timing
fetal electrocardiography
fetal heart rate
Opis:
Cardiotocography as a simultaneous recording of fetal heart rate (FHR) and uterine contraction activity is a basic method of evaluation of fetal condition. Correct variability of the fetal heart rate is an indirect sign of adequate oxygenation of a fetus. Unfortunately, the reverse case is not always true, signs suggesting pathological changes can also appear in recording when the fetal is not at risk. The cardiotocography shall then be recognized as a more screening than diagnostic method. It will be interesting to develop a non-invasive method being complementary to routine cardiotocography. This method should allow the adequate prediction of a bad neonatal outcome when the test is abnormal. The paper shows the system that makes possible cardiotocograms analysis in parallel with the assessment of additional parameters determined from comparison of mechanical and electrical fetal heart activity signals. The studies are aimed at development of set of parameters that are high correlated with clinical outcome.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT27-34
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies