Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Hao, D." wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Genotypic variation of Cunninghamia lanceolata revealed by phenotypic traits and SRAP markers
Autorzy:
Zheng, H.
Duan, H.
Hu, D.
Li, Y.
Hao, Y.
Powiązania:
https://bibliotekanauki.pl/articles/41212.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Instytut Dendrologii PAN
Opis:
The success of a tree breeding program largely depended on the available genetic variability of the germplasms. Our present study aimed to assess the phenotypic variation and DNA variability using sequence-related amplified polymorphism (SRAP) markers among 50 Cunninghamia lanceolata (Chinese fir) genotypes. Extensive phenotypic variations (p < 0.05 or 0.01) were found for all the growth and wood property traits (height, diameter at breast height, stem volume, and wood basic density, hygroscopicity, heart-wood ratio, tracheid length, tracheid diameter and tracheid length-diameter ratio) with coefficients of variation spanning from 6.8 to 31.3%. At the DNA level, thirty-five SRAP primer combinations produced 498 bands with 89.4% polymorphism across genotypes; moreover, the Nei’s gene diversity was detected to be ranged between 0.204 and 0.373 (mean = 0.279), while the Shannon’s Information Index stretched from 0.324 to 0.555 with an average value of 0.427. Significance (p < 0.01) of the variability of SRAP polymorphism among genotypes was further demonstrated by AMOVA. These results indicated a relatively high level of genetic diversity in genotypes. The SRAP’ dendrogram additionally revealed that these genotypes could be split into 7 clusters with higher discriminating capacity over that of phenotype. Notably, a total of 99 statistically significant (p < 0.05) marker-trait associations related to the growth and wood property traits were identified. These marker-trait associations corresponded to 77 different SRAP markers with R2 (percentage of the phenotypic variation explained by marker) ranging from 8.3 to 26.4%.
Źródło:
Dendrobiology; 2015, 74
1641-1307
Pojawia się w:
Dendrobiology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-dimensional biomechanical modeling and simulation of trephine cutting cornea for keratoplasty
Autorzy:
Su, P.
Lu, D.
Deng, S.
Zhang, L.
Hao, Y.
Yang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/307486.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
rogówka
biomechanika
kryterium wytężeniowe
FEM
cornea
biomechanics
failure criterion
finite element simulation
Opis:
Trephination is one of the basic operations of keratoplasty, and the biomechanical mechanism of the operation can be revealed based on three-dimensional modeling and simulation of trephine cutting cornea. Methods: Based on the analysis of the physical and biomechanical characteristics of corneal trephination, a three-dimensional numerical model of corneal trephination is built, where the cornea can be simplified to two layers structure including stroma and epithelium, and the trephine cuts the cornea under the vertical motion load and the rotational motion load. A three-dimensional failure criterion of corneal material is proposed based on the yield strength theory. On this basis, trephination simulation is carried out, and the units of corneal material are removed from the model when they meet the defined failure criterion. Results: Under the given parameters including the velocity, the angle and the angular velocity, the trephine force curves, include the linear cutting force and the rotary cutting force are obtained, and show the change of the forces with displacement during the process of trephination simulation. The maps of the equivalent stress show the destruction and deformation of the cornea. Then, the experiment of robotic trephination is carried out under the same parameters and the effectiveness of the simulation is evaluated. Conclusions: Based on mechanics theory and finite element method, the process of trephine cutting cornea has been reproduced, and the interaction mechanism is revealed, which lays the foundation for the development of real-time simulation and virtual system of the corneal surgery.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 23-33
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies