Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "bioaerozol" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Bioaerosol-forming actinomycetes at the selected sites of Kraków
Promieniowce tworzące bioaerozol w wybranych miejscach Krakowa
Autorzy:
Grzyb, J.
Frączek, K.
Powiązania:
https://bibliotekanauki.pl/articles/389452.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
Actinomycetes
bioaerosol
air dustiness
Kraków
promieniowce
bioaerozol
zapylenie
Opis:
Krakow is a city where, due to mostly so-called low-stack emissions and intensified traffic, air dustiness continues to increase and often, especially in winter, the threshold values of dustiness are exceeded. Air dustiness increases the number of airborne microorganisms, as they are associated with particles of dust to form bioaerosols. Actinomycetes are one of the most significant components of bioaerosol. Their presence in bioaerosol is dangerous to human health, since even very low concentrations of these microorganisms can cause allergic reactions. The aim of this study was to verify the relationship between the concentration of actinomycetes in the air of Krakow depending on spatial variation of thermal conditions and the degree of air dustiness. The study was conducted using a cascade impactor for bioaerosol particle separation, including the respirable fraction. Moreover, the measurements of air dustiness were performed simultaneously, separating 4 dust fractions. The research was conducted over 12 months (full calendar year) and the measurements were performed once per month, within one day, at 16 research sites. The lowest average numbers of actinomycetes were recorded in places characterized by little urban green space (eg Main Square or crossroads). On the other hand, the highest numbers were found in green areas (eg Blonia Park meadows, green area at the Krakow University of Technology). Based on the normative classification of air quality (Polish Standard PN-89/Z-04111/02) the number of actinomycetes in 75 % measurements showed that the air was polluted, including heavily polluted air in 16 % measurements. The most common actinomycetes belonged to the genus Streptomyces (St. albus, St. badius, St. globisporus).
Kraków jest miastem, w którym głównie na skutek tzw. niskiej emisji oraz wzmożonego ruchu kołowego zapylenie powietrza wciąż wzrasta i nierzadko szczególnie w okresie zimowym są przekraczane progowe wartości zapylenia. Zapylenie powietrza wpływa na zwiększenie się ilości drobnoustrojów Bioaerosol-Forming Actinomycetes at the Selected Sites of Krakow 451 w powietrzu, gdyż te ostatnie wiążą się z cząstkami pyłów, tworząc bioaerozol. Jednym z ważnych składników bioaerozolu są promieniowce. Ich obecność w bioaerozolu jest groźna dla zdrowia ludzkiego, gdyż nawet ich bardzo niskie stężenia mogą działaæ alergizująco. Celem niniejszych badań była weryfikacja zależności pomiędzy stężeniem promieniowców w powietrzu na obszarze Krakowa, przestrzennym zróżnicowaniem stosunków termicznych oraz stopniem zapylenia powietrza. Do badañ użyto impaktora kaskadowego w celu uzyskania rozdziału cząstek bioaerozolu, w tym frakcji respirabilnej. Jednocześnie wykonywane były pomiary stopnia zapylenia z podziałem na 4 frakcje. Badania były wykonywane przez 12 miesięcy (pełen rok kalendarzowy), raz w miesiącu, w ciągu jednego dnia, na 16 stanowiskach pomiarowych. Najniższe średnie liczebności promieniowców notowano w miejscach, gdzie jest mało zieleni (np. Rynek Główny, czy też skrzyżowanie ulic). Najwyższe liczebności stwierdzono na terenach zielonych (np. Błonia, teren zielony przy Politechnice Krakowskiej). Promieniowce zgodnie z klasyfikacją jakości powietrza atmosferycznego (Polska Norma PN-89/Z-04111/ 02) powodowały, że w przypadku 75 % wykonanych pomiarów powietrze było zanieczyszczone, w tym silnie zanieczyszczone dla 16 % pomiarów. Najczęściej stwierdzano występowanie promieniowców z rodzaju Streptomyces (St. albus, St. badius, St. globisporus).
Źródło:
Ecological Chemistry and Engineering. A; 2013, 20, 4-5; 443-452
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy monitoringu zanieczyszczeń mikrobiologicznych powietrza
The problems of microbiological air contamination monitoring
Autorzy:
Chmiel, M.
Frączek, K.
Grzyb, J.
Powiązania:
https://bibliotekanauki.pl/articles/339315.pdf
Data publikacji:
2015
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
air contamination
bacteria
bioaerosol
fungi
microorganisms
bakterie
bioaerozol
grzyby
mikroorganizmy
zanieczyszczenie powietrza
Opis:
W pracy omówiono składniki bioaerozolu ze szczególnym uwzględnieniem zanieczyszczeń mikrobiologicznych (bakterii i grzybów), źródeł ich pochodzenia (naturalne i antropogeniczne) oraz rozprzestrzeniania się i zagrożeń wynikających z obecności drobnoustrojów w powietrzu wewnętrznym i atmosferycznym. Przedstawiono przykładowe choroby, których czynniki przenoszone są drogą powietrzną, oraz problemy związane z regularnym monitoringiem zanieczyszczeń biologicznych atmosfery. Odrębną część pracy poświęcono sposobom badań mikrobiologicznych, przedstawiono krótko wybrane metody badań powietrza oraz omówiono ich wady i zalety. W ostatniej części przedstawiono problemy dotyczące oceny stopnia zanieczyszczenia powietrza przez drobnoustroje. Problemy te wynikają z braku obowiązujących norm oraz innych regulacji prawnych związanych z mikrobiologicznym skażeniem powietrza, które umożliwiałyby jednoznaczną interpretację wyników badań.
This study discusses the components of bio-aerosol – with particular emphasis on the microbiological contaminants (bacteria and fungi), their sources (natural and anthropogenic), spread and risks resulting from the presence of microorganisms in the indoor and atmospheric air. The paper presents examples of diseases transmitted by air and the problems associated with regular monitoring of microbiological contamination of the atmosphere. A part of the work is devoted to the methods of microbiological testing of air pollution and presents briefly chosen methods and discusses their advantages and disadvantages. The last section presents problems with assessing the degree of air pollution by microorganisms resulting from the absence of applicable standards and other regulations related to the microbiological contamination of air, which would allow for unambiguous interpretation of research results
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2015, 15, 1; 17-27
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobowe zmiany składu ilościowego aerozolu bakteryjnego w Krakowie
Studies of diurnal changes in the quantitative composition of the bacterial bioaerosol in the city Cracow
Autorzy:
Grzyb, J.
Chmiel, M. J.
Swędrzyńska, D.
Powiązania:
https://bibliotekanauki.pl/articles/339113.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bakterie
bioaerozol
jakość powietrza w Krakowie
przebieg dobowy
air quality in Cracow
bacteria
bioaerosol
diurnal changes
Opis:
Cząstki bioaerozolu o średnicy aerodynamicznej 10 μm i mniejszej (PM10) to jeden z najbardziej niebezpiecznych składników powietrza atmosferycznego, dlatego aerozol ziarnisty PM10 jest obecnie podstawowym wskaźnikiem jakości powietrza w krajach Unii Europejskiej. Mając na uwadze wagę powyższego problemu wykonano badania, które miały na celu ocenę dobowych zmian składu ilościowego bakterii znajdujących się w powietrzu atmosferycznym w wybranych punktach Krakowa w zależności od nasilenia ruchu samochodowego oraz zapylenia. Pomiary przeprowadzono w lipcu 2013 r. na dwóch stanowiskach badawczych w odstępach 2-godzinnych w czasie 48 h. Stężenie aerozolu bakteryjnego oznaczono z użyciem 6-stopniowego impaktora Graseby-Andersena, a badania zapylenia (całkowitego – PM10 i frakcji respirabilnej – PM4) wykonano za pomocą pyłomierza DustTrak II. Czynnikami istotnie różnicującymi stężenie bakterii w powietrzu była lokalizacja stanowisk badawczych (różnice od 240 do 410% w zależności od grupy bakterii) oraz pora dnia. Największe zanieczyszczenie bakteriologiczne powietrza stwierdzono w porze dziennej na stanowisku przy alei Mickiewicza. Pomiary zapylenia wykazały większe stężenie pyłu w obydwu stanowiskach badawczych w porze nocnej niż w ciągu dnia. Wielokrotnie, głównie na stanowisku zlokalizowanym bezpośrednio przy trakcie komunikacyjnym, notowano przekroczenia dopuszczalnych wartości zapylenia. Największe stężenie bakterii dotyczyło frakcji o średnicach aerodynamicznych cząstek powyżej 7 μm. W większości próbek z obu stanowisk badawczych stwierdzono obecność bakterii α- i β-hemolizujących we frakcji respirabilnej, co może mieć niekorzystny wpływ na zdrowie ludzi, podobnie jak zwiększone wartości zapylenia, szczególnie frakcji respirabilnej.
Bioaerosol particles with an aerodynamic diameter of 10 microns and smaller (PM10) are one of the most dangerous components of air, because the aerosol fraction PM10 is now a key indicator of air quality in the European Union. Considering the importance of this issue study was aimed at determining the quantitative composition of bacteria in the atmospheric air at selected points Cracow depending on the intensity of traffic and air dust. Analysis was carried out in July 2013 in two locations at intervals of 2 hours for 48 hours. The concentration of bacterial aerosol was determined using a 6-stage impactor Graseby-Andersen and study dust (total – PM10, respirable fraction – PM4) was performed using the dust meter DustTrak II. The factors significantly differentiating concentration of bacteria in the air was the location of sampling point (differences of 240 to 410% depending on the group of bacteria) and time of day. The highest bacteriological contamination has been demonstrated in the daytime on sampling point at Mickiewicza Avenue. The results showed higher concentrations of dust, regardless of the location, at night time. Repeatedly, mainly at the sampling point located directly on the traffic route, was reported exceedance of dust limits. The highest concentrations of bacteria were related to the fraction of the aerodynamic particle diameters greater than 7 μm. In the majority of samples from both locations the α- and β-hemolytic bacteria were present in the respirable fraction, which may have an adverse effect on human health as well as elevated pollination.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2017, 17, 2; 93-101
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies