Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gawroński, B." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Preliminary characteristic of composite coatings C/HAp produced respectively by RF PACDV and sol-gel methods
Wstępna charakterystyka kompozytowych powłok C/HAp wytworzonych odpowiednio metodami RF PACVD oraz zol-żel
Autorzy:
Gawroński, J.
Pietrzyk, B.
Powiązania:
https://bibliotekanauki.pl/articles/351780.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydroxyapatite
sol-gel
adhesion
carbon
implant
hydroksyapatyt
zol-żel
przyczepność
węgiel
Opis:
The required high mechanical strength and the reliability of implants on one side and a lack of toxic elements in those materials, on the other side, causes restrictions in use of metal alloys for austenitic steel, alloys of cobalt matrix and even titanium alloys. However, elements harmful to human body structure such as chromium, nickel and vanadium could not have been eliminated so far. An attempt to reduce detrimental effects of above elements on the living organism are surface modifications of materials predicted for implants through the deposition of protective layers. The C/HAp composite coating was prerared by deposition of carbon layer directly on surgical steel with RF PACVD method and manufacturing of hydroxyapatite layer by sol-gel method. It was proved that carbon film significantly increases adhesion of the composite C/HAp coating. It is due to the diffusive character of bonding between carbon layer and metallic substrate not only by adhesion as in the case with hydroxyapatite deposited directly on metal base. Adhesion of both synthesized coatings was determined using nanoindentation technique. X-Ray diffraction was used for phase composition evaluation. Atomic Force Microscope revealed topography of raw, carbon and C/HAp surfaces. Elemental composition of carbon and composite layers was investigated by scanning electron microscope equipped with x-ray energy dispersive spectroscopy detector.
Wymagana wysoka wytrzymałość mechaniczna i niezawodność implantów z jednej strony i nie stosowanie w materiałach pierwiastków toksycznych (alergizujących) z drugiej strony, powoduje ograniczenia w stosowaniu stopów metalicznych, przeznaczonych na implanty, do stali austenitycznej, stopów na osnowie kobaltu i stopów tytanu. Mimo starań, nie udało się jednak z materiałów tych całkowicie wyeliminowac pierwiatków szkodliwych dla organizmu jak choćby chromu, niklu i wanadu. Próbą ograniczenia złego wpływu pierwiastków na żywy organizm są modyfikacje powierzchni materiałów przeznaczonych na implanty poprzez wytwarzanie na nich warstw ochronnych. Kompozytowa powłoka węgiel/hydroxyapatyt została otrzymana przez naniesienie w pierwszej kolejności warstwy węglowej bezpośrednio na stal AISI 316L metodą RF PACVD a następnie warstwy hydroxyapatytu metodą zol-żel. Zostało udowodnione, że warstwa węglowa w sposób znaczący zwiększa adhezje kompozytu C/HAp do zastosowanego podłoża. Jest to wynikiem dyfuzyjnego charakteru połączenia pomiędzy warstwą węglową a podłożem a nie jak w przypadku bezpośredniego naniesienia powłoki HAp na podłoże gdzie połączenie takie ma charakter adhezyjny. Adhezja obu wytworzonych powłok (C, C/HAp) została określona po użyciu nanoindentera F-MY MTS Instruments Nano G-200 metodą scratch test. Analizę składu fazowego podłoża oraz uzyskanej powłoki kompozytowej dokonano metodą dyfrakcji rentgenowskiej. Badania topografii powierzchni z wytworzonymi warstwami węglową oraz węglowo/hydroxyapatytowa przeprowadzono przy użyciu mikroskopu sił atomowych (AFM) F-my Veeco Multimode z kontrolerem NanoScoper. Chropowatość warstwy wierzchniej określono przy pomocy parametru Ra. Mikroanalizę rentgenowską wykonano przy pomocy przystawki Thermo-Noran zainstalowanej w mikroskopie scaningowym HITACHI S-3000N. Zastosowano technikę analizy liniowej (EDS).
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 569-572
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Copper on the Crystallization Process, Microstructure and Selected Properties of CGI
Autorzy:
Gumienny, G.
Kacprzyk, B.
Gawroński, J.
Powiązania:
https://bibliotekanauki.pl/articles/381656.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
theory of crystallization
compacted graphite iron
copper
DTA method
teoria krystalizacji
zagęszczone żelazo grafitowe
miedź
metoda DTA
Opis:
The paper presents the results of the research on the effect of copper on the crystallization process, microstructure and selected properties of the compacted graphite iron. Compacted graphite in cast iron was obtained using Inmold process. The study involved the cast iron containing copper at a concentration up to approximately 4%. The effect of copper on the temperature of the eutectic crystallization as well as the temperature of start and finish of the austenite transformation was given. It has been shown that copper increases the maximum temperature of the eutectic transformation approximately by 5 oC per 1% Cu, and the temperature of the this transformation finish approximately by 8 o C per 1% Cu. This element decreases the temperature of the austenite transformation start approximately by 5 oC per 1% Cu, and the finish of this transformation approximately by 6oC per 1% Cu. It was found that in the microstructure of the compacted graphite iron containing about 3.8% Cu, there are still ferrite precipitations near the compacted graphite. The effect of copper on the hardness of cast iron and the pearlite microhardness was given. This stems from the high propensity to direct ferritization of this type of cast iron. It has been shown copper increases the hardness of compacted graphite iron both due to its pearlite forming action as well as because of the increase in the pearlite microhardness (up to approx. 3% Cu). The conducted studies have shown copper increases the hardness of the compacted graphite iron approximately by 35 HB per 1% Cu.
Źródło:
Archives of Foundry Engineering; 2017, 17, 1; 51-56
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nickel in Compacted Graphite Iron
Autorzy:
Gumienny, G.
Kurowska, B.
Szymczak, T.
Gawroński, J.
Powiązania:
https://bibliotekanauki.pl/articles/352803.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
compacted graphite iron
crystallization process
DTA method
Opis:
The paper presents results of the research work concerning effects of nickel concentration on the crystallization process, microstructure and selected properties of the compacted graphite iron. Compacted graphite in the cast iron was obtained with use of the Inmold process. The study has comprised the cast iron containing nickel up to concentration providing obtainment of austenitic microstructure of the matrix. The effect of the nickel on temperature of the eutectic crystallization was specified. It has been presented composition of the cast iron matrix in function of nickel concentration in a casting with wall thickness of 3 mm and 24 mm. Moreover, it has been presented conditions defining the possibility of obtaining an austenitic and martensitic compacted graphite iron. Effect of the nickel on hardness of the cast iron was described.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 657-662
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warstwy hydroksyapatytu na zmodyfikowanej warstwą węglową powierzchni AISI 316L
Hydroxyapatite coatings on the carbon reinforced surface of AISI 316L
Autorzy:
Niedzielska, A.
Mróz, W.
Gawroński, J.
Puchalska, A.
Pietrzyk, B.
Zydorczyk, A.
Szymanowski, H.
Powiązania:
https://bibliotekanauki.pl/articles/285508.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
hydroksyapatyt
warstwa węglowa
implant medyczny
hydroxyapatite
carbon layer
medical implants
Opis:
W ostatnich latach zauważa się wzrost ilości implantacji wszczepów medycznych, których głównym celem jest zastąpienie uszkodzonych chorobowo lub urazowo organów (protezy stawu biodrowego, kolanowego itp.). Związane to jest z wprowadzeniem do organizmu dużych ilości metali i narażeniem pacjentów na ich oddziaływanie na organizm. Na świecie w wielu laboratoriach prowadzone są badania nad ograniczeniem tego wpływu na zdrowie pacjenta. W pracy przedstawiono wstępne badania nad wytwarzaniem nowego kompozytu węglowo-hydroksyapatytowego na podłożach metalicznych stosowanych w medycynie, którego główną rolą jest ograniczenie przenikania jonów metali do organizmu, jak i poprawa właściwości mechanicznych.
In recent years one may observe a constant increase in the number of implantations of medical implants the main objective of which is the replacement of damaged organs due to an illness or injury (hip or knee joint prostheses, etc.). This is connected with the introduction of a large number of metals to the organisms of patients. Furthermore, the patients are exposed to the activity of those metals in their organisms. In the laboratories worldwide there are carried out the investigations aimed at reducing this detrimental influence on the health of the patients. In the study the preliminary research into the production of a new carbon-hydroxyapatite composite on metal substrates in medicine is presented. The crucial role of such a composite is to limit the phenomenon of metalosis in the organism of the patient and to enhance its mechanical properties.
Źródło:
Engineering of Biomaterials; 2009, 12, 85; 23-28
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies