Tytuł:
Ultrasonic Experimental Evaluation of the Numerical Model of the Internal Fluid Flow in the Kidney Cooling Jacket
Autorzy:
Gambin, Barbara
Korczak-Cegielska, Ilona
Secomski, Wojciech
Kruglenko, Eleonora
Nowicki, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/31340112.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
multi-canal system
fluid flow prediction
cooling jacket
flow Doppler measurement
Opis:
Kidney Cooling Jacket (KCJ) preserves the kidney graft, wrapped in the jacket, against the too fast time of temperature rise during the operation of connecting a cooled transplant to the patient’s bloodstream. The efficiency of KCJ depends on the stationarity of the fluid flow and its spatial uniformity. In this paper, the fluid velocity field inside the three different KCJ prototypes has been measured using the 20 MHz ultrasonic Doppler flowmeter. The simplified 2D geometrical model of the prototypes has been presented using COMSOL-Multiphysics to simulate the fluid flow assuming the laminar flow model. By comparing the numerical results with experimental data, the simplified 2D model is shown to be accurate enough to predict the flow distribution of the internal fluid velocity field within the KCJ. The discrepancy between the average velocity measured using the 20 MHz Doppler and numerical results was mainly related to the sensitivity of the velocity measurements to a change of the direction of the local fluid flow stream. Flux direction and average velocity were additionally confirmed by using commercial colour Doppler imaging scanner. The current approach showed nearly 90% agreement of the experimental results and numerical simulations. It was important for justifying the use of numerical modelling in designing the baffles distribution (internal walls in the flow space) for obtaining the most spatially uniform field of flow velocity.
Źródło:
Archives of Acoustics; 2022, 47, 3; 389-397
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of High Frequency Imaging and Doppler System for the Measurements of the Radial Artery Flow-Mediated Dilation
Autorzy:
Nowicki, Andrzej
Gambin, Barbara
Secomski, Wojciech
Trawiński, Zbigniew
Szubielski, Michał
Tymkiewicz, Ryszard
Olszewski, Robert
Powiązania:
https://bibliotekanauki.pl/articles/176847.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
flow mediated dilation
shear rate
axial resolution
elevation resolution
pulsed Doppler
ultrasonic imaging
Opis:
Objectives: In the article we describe the new, high frequency, 20 MHz scanning/Doppler probe designed to measure the flow mediated dilation (FMD) and shear rate (SR) close to the radial artery wall. Methods: We compare two US scanning systems, standard vascular modality working below 12 MHz and high frequency 20 MHz system designed for FMD and SR measurements. Axial resolutions of both systems were compared by imaging of two closely spaced food plastic foils immersed in water and by measuring systolic/diastolic diameter changes in the radial artery. The sensitivities of Doppler modalities were also determined. The diagnostic potential of a high frequency system in measurements of FMD and SR was studied in vivo, in two groups of subjects, 12 healthy volunteers and 14 patients with stable coronary artery disease (CAD). Results: Over three times better axial resolution was demonstrated for a high frequency system. Also, the sensitivity of the external single transducer 20 MHz pulse Doppler proved to be over 20 dB better (in terms of a signal-to-noise ratio) than the pulse Doppler incorporated into the linear array. Statistically significant differences in FMD and FMD/SR values for healthy volunteers and CAD patients were confirmed, p-values < 0:05. The areas under Receiver Operating Characteristic (ROC) curves for FMD and FMD/SR for the prediction CAD had the values of 0.99 and 0.97, respectively. Conclusions: These results justify the usefulness of the designed high-frequency scanning system to determine the FMD and SR in the radial artery as predictors of coronary arterial disease.
Źródło:
Archives of Acoustics; 2019, 44, 4; 637-644
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies