Wyszukujesz frazę "PD phase-resolved patterns" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
High voltage harmonics induced modifications of PD phase-resolved patterns
Autorzy:
Florkowski, M.
Florkowska, B.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/141372.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical insulation system
diagnostics
harmonics
partial discharges
phase-resolved patterns
Opis:
Partial discharges (PD) are influencing electrical insulating systems of high voltage electrical devices. Typically, in laboratory and diagnostics AC tests focused on measuring and analysis of PD, a pure sinusoidal voltage waveform is assumed. However, in practice the spectral content of the working voltage is rarely so ideal and additional spectral components have a significant impact on the discharge behaviour in electrical insulation systems. In this paper the influence of voltage harmonics on PD behaviour and phase-resolved PD patterns evolution is analysed. The presented experiments were conducted on a specimen representing a gaseous inclusion embedded in electrical insulation. The experimental results showed that various harmonic compositions superimposed on the fundamental sinusoidal waveform have a significant impact on PD intensity and maximum charge. In consequence, the derived patterns of PD phase, and magnitude distributions are distorted, and statistical parameters calculated on their basis are changed. In certain environments, neglecting harmonic content in the testing voltage may lead to a misleading interpretation and assessment of PD severity.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 231--246
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distribution and phase-resolved patterns of partial discharges form in non-uniform electric field in air
Rozkłady i obrazy fazowe form wyładowań niezupełnych w niejednorodnym polu elektrycznym w powietrzu
Autorzy:
Florkowska, B.
Zydroń, P.
Roehrich, J.
Powiązania:
https://bibliotekanauki.pl/articles/266690.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania niezupełne w powietrzu
zakłócenia
obrazy fazowo-rozdzielcze wnz
partial discharges in air
disturbances
phase-resolved PD patterns
Opis:
Corona discharge is a form of partial discharges (PD) occurring at non-uniform electric field in air. This kind of discharges could be very useful in practical electrotechnology application, however in many cases corona discharges lead to serious technical problems. Corona discharge is a source of electro-magnetic interferences of wide frequency range, and e.g. during electrical power equipment diagnostic measurements at AC testing voltages it produces unneeded quasi-synchronic disturbances. Paper presents results of corona discharges investigations by means of partial discharge phase-resolved measurement method. Model needle-to-plane electrode systems were used during laboratory experiments as well defined corona discharge sources. PD forms and phase-resolved PD patterns were observed and analyzed for different setup and testing voltage parameters.
Wyładowania niezupełne w powietrzu w polu niejednorodnym są jedną z form wyładowań elektrycznych. Wyładowania te znajdują zastosowanie w pewnych aplikacjach technologicznych, jednak w wielu przypadkach powodują poważne problemy techniczne. Są źródłem zaburzeń elektromagnetycznych i podczas badań diagnostycznych urządzeń elektroenergetycznych napięciem przemiennym powodują powstawanie niepożądanych zakłóceń quasi-synchronicznych. Artykuł przedstawia wyniki badań wnz w polu niejednorodnym metodą pomiarów fazowo-rozdzielczych. Zastosowano układy modelowe elektrod typu ostrze-płaszczyzna. Rejestrowano obrazy fazoworozdzielcze dla różnych konfiguracji elektrod i wartości napięć probierczych. 5.0kV 6.0kV
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 51-54
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies