Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kucuk, K." wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Modelling of Power Loss in Electrical Steels
Autorzy:
Kucuk, I.
Erturk, K.
Haciismailoglu, M.
Derebasi, N.
Powiązania:
https://bibliotekanauki.pl/articles/1813590.pdf
Data publikacji:
2008-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Bb
84.35.+i
Opis:
This paper presents a new artificial neural network approach based on loss separation model to compute power loss on different types of electrical steels. The network was trained by a Levenberg-Marquardt algorithm. The results obtained by using the proposed model were compared with a commonly used conventional model. The comparison has shown that the neural network model is in good agreement with experimental data with respect to the conventional model.
Źródło:
Acta Physica Polonica A; 2008, 113, 1; 147-150
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Thickness on Magnetic Properties of $Fe_{36}Co_{36}B_{19.2}Si_{4.8}Mo_2W_2$ Thin Film Prepared by Thermionic Vacuum Arc
Autorzy:
Perincek, F.
Erturk, K.
Aykol, M.
Kucuk, I.
Akdeniz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1490937.pdf
Data publikacji:
2012-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Kj
75.50.Vv
75.60.Ej
75.70.Ak
Opis:
$Fe_{36}Co_{36}B_{19.2}Si_{4.8}Mo_2W_2$ amorphous thin films have been produced by thermionic vacuum arc with thickness varying from 200 nm to 260 nm. X-ray diffraction has been employed to reveal a predominant amorphous phase in the as-prepared samples, although a small crystalline fraction cannot be excluded. The bulk magnetic properties of thin films were examined at room temperature using an ADE Magnetics EV9 vibrating sample magnetometer with maximum magnetic field strength of 1750 kA/m, real-time field control and dynamic gauss range capable of reaching a resolution of 0.08 A/m at low fields. The minimum value of the coercivity for the as-prepared samples was about 7 kA/m.
Źródło:
Acta Physica Polonica A; 2012, 121, 1; 147-148
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies