Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "energy-efficient buildings" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Pilotnye proekty individual’nyh zilyh domov s nizkim i ul’tranizkim energopotrebleniem s ispol’zovaniem bazovyh principov koncepcii passivnogo doma v Rossii
Pilot projects of individual residential houses for low and very low energy consumption with the use of the basic principles of passive house concept in Russia
Autorzy:
Elohov, A.
Powiązania:
https://bibliotekanauki.pl/articles/2065116.pdf
Data publikacji:
2012
Wydawca:
Politechnika Częstochowska
Tematy:
energy efficient buildings
passive house
reducing the cost of construction
Opis:
V Rossii realizovano (ili v processe realizacii) neskol’ko ob’ektov s ispol’zovaniem bazovyh komponentov passivnogo doma v Moskve i Moskovskoj oblasti, Ekaterinburge, Niznem Novgorode i Sankt-Peterburge. Pilotnye proekty otnosatsa k zdaniam s nizkim potrebleniem teplovoj energii na otoplenie. Dla dostizenia kriteriev standarta passivnogo doma pri proektirovanii neobhodimo kacestvenno vypolnit’ 5 osnovnyh trebovanij, a imenno: horosaa teploizolacia, otsutstvie teplovyh mostov v orgazdauscih konstrukciah, effektivnye okna, sertificirovannye dla passivnogo doma, germeticnaa vnutrennaa obolocka, mehaniceskaa sistema ventilacii s vysokoeffektivnoj rekuperaciej tepla. V nastoascij moment suscestvuet rad metodik dla kontrola za kacestvom stroitel’stva: teplovizionnoe obsledovanie, test BlowerDoor. Odnoj iz osnovnyh zadac i problemnyh voprosov avlaetsa snizenie stoimosti stroitel’stva takih zdanij v Rossii do urovna standartnyh zdanij.
There are realized a few projects using basic components of passive house in Russia: Moscow region, Yekaterinburg, Nizhny Novgorod and St. Petersburg. Pilot projects have low and ultra-low energy consumption for space heating. Energy efficient buildings and passive houses should the following have main features: good insulation, no thermal bridges, effective windows, certified for passive house; internal building envelope; mechanical ventilation system with highly efficient heat recovery coefficient. It also requires quality control of construction: heat monitoring with thermal imager and BlowerDoor test. One of the main purposes and problematic questions is reducing the cost of construction of buildings in Russia to the level of standard buildings.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2012, 2 (10); 13--21
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies