Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "washings" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Treatment of Pool Water Installation Washings in A Flocculation/Ultrafiltration Integrated System
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/123294.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pressure driven membrane processes
washings
flocculation
waste streams treatment
ultrafiltration
Opis:
The article presents the possibilities of employing an integrated flocculation/ultrafiltration system in the treatment of washings generated upon the rinsing of filter beds in pool water installations. Single ultrafiltration process was used as a comparator. Flocculation was carried out using commercial dialuminium pentahydroxychloride solution widely used at pool facilities for the removal of contaminants in flocculation processes. The studies consisted in determination of correlations between the conditions of the flocculation process (variable doses of Al3+ ions: from 4 to 280 mg/L) and the transport/separation characteristics of ultrafiltration membranes. Flocculation was performed at different temperatures of washings i.e. 8, 21, and 30°C for each of the pre-defined doses. Ultrafiltration was highly capable of reducing the turbidity of washings and removing a large group of contaminants as determined by turbidimetry and UV254 absorbance measurements. The studies revealed that the best transport/ separation characteristics of ultrafiltration membranes were obtained in a system in which ultrafiltration was performed following flocculation of washings carried out at 21°C using a 40 mgAl3+/L solution. The turbidity was reduced by ca. 99% and UV absorption was reduced by ca. 94% while the relative volumetric stream of the permeate increased by more than 35% (as compared to the filtration of washings in a single-process system). Membrane ultrafiltration significantly increased the quality of the waste stream consisting of washings from the pool water installation. Pre-processing of washings is required before ultrafiltration in order to limit the blocking of membrane pores. Flocculation may be one of such pre-processing methods.
Źródło:
Journal of Ecological Engineering; 2017, 18, 5; 96-103
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125768.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
integrated process
washings nanofiltration
coagulation
swimming pool water installation
Opis:
Przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu: koagulacja-sedymentacja-nanofiltracja do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5-3,0 mg Al/dm3) oraz sedymentacji (przy czasie trwania 0,5-24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mg Al/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Cząsteczki osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, przy wyższej dawce koagulantu (3,0 mg Al/dm3), równocześnie spowodowały stopniowy wzrost zdolności separacyjnych membrany i utworzenie tzw. membrany wtórnej. Przy czym charakteryzowała się ona mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5-3.0 mg Al/dm3 and sedimentation where the scope of duration 0.5-24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mg Al/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after Edyta Łaskawiec, Mariusz Dudziak i Joanna 184 Wyczarska-Kokot coagulation with dose 3.0 mg Al/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 177-184
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/387996.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
integrated process
washings nanofiltration
coagulation
sedimentation
swimming pool water
Installation
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
Opis:
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5–3.0 mgAl/dm3 and sedimentation where the scope of duration 0.5–24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. DK GE Osmonics membrane was used as a nanofiltration membrane. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mgAl/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after coagulation with dose 3.0 mgAl/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
W pracy przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu koagulacji–sedymentacji–nanofiltracji do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5–3,0 mgAl/dm3) oraz sedymentacji (czas trwania 0,5–24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mgAl/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Obecność cząsteczek osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, w której zastosowano wyższą dawkę koagulantu (3,0 mgAl/dm3), równocześnie spowodowała stopniowy wzrost zdolności separacyjnych membrany – utworzyła się tzw. membrana wtórna charakteryzująca się mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 227-236
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie wody popłucznej z instalacji basenowej w jednostkowym membranowym procesie ultrafiltracji oraz w układzie zintegrowanym napowietrzanie-ultrafiltracja
Treatment of aqueous rinsing liquids of the pool water installation in a unit process of membrane ultrafiltration and in the airing-ultrafiltration integrated system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/270649.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
popłuczyny
woda basenowa
ultrafiltracja
ciśnieniowe procesy membranowe
oczyszczanie strumieni wód odpadowych
washings
pool water
ultrafiltration
pressure driven membrane processes
treatment of streams of wastewater
Opis:
W pracy przedstawiono możliwość wykorzystania membranowego procesu ultrafiltracji do oczyszczania popłuczyn z instalacji basenowych. Badania obejmowały proces jednostkowy ultrafiltracji oraz zintegrowany układ napowietrzanie-ultrafiltracja, który pozwolił na częściowe usunięcie zanieczyszczeń występujących w nadawie. Porównano membrany o zróżnicowanym materiale polimerowym oraz różnej wartości granicznej masy molowej cut-off. Określono wpływ zastosowanego procesu wstępnego na zdolności transportowo-separacyjne membran o różnych własnościach fizyczno-chemicznych. Uzyskano wysoką wydajność hydrauliczną we wszystkich prowadzonych filtracjach (w zakresie od 1,23·10-5 do 1,40·10-7 m³/m²·s). W zakresie usuwania mętności badane układy charakteryzowały się współczynnikiem usunięcia przekraczającym 90%. Odnotowano znaczące usunięcie grupy zanieczyszczeń opisanych przez wskaźnik ogólny, tj. absorbancję w nadfiolecie UV254. Przeprowadzone badania wykazały możliwość wykorzystania ultrafiltracji do odzysku wody basenowej z popłuczyn poprocesowych.
The paper presents the possibility of using the membrane ultrafiltration process for the treatment of washings from pool water systems. The tests included a unit ultrafiltration process and airing-ultrafiltration integrated system which partly removed contamination from the feed material. Membranes of various polymere materials and molar mass cut-off were compared. This helped to determine the influence of the used initial process on transport and separation abilities of the membranes of different physical and chemical features. High hydraulic performance was obtained in all performed filtration actions (1.23·10-5 ÷ 1.40·10-7 m³/m²·s). In respect of fighting turbidity, all tested systems had a removal rate of more than 90%. It was also noted that a significant amount of contamination described by the general indicator, which is specific UV254 absorbance, was removed. The tests proved that ultrafiltration can be used for recovery pool water from post-process washings.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 4; 238-245
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies