Tytuł:
Effect of elliptical deformation of the acetabulum on the stress distribution in the components of hip resurfacing surgery
Autorzy:
Stempin, R.
Dragan, S. Ł.
Kulej, M.
Filipiak, J.
Dragan, S.
Powiązania:
https://bibliotekanauki.pl/articles/306854.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
alloplastyka stawu biodrowego
rozkład naprężeń
FEM
hip resurfacing
stress distribution
finite element analysis
Opis:
Hip resurfacing surgery is a matter of controversy. Some authors present very good late results of 99% survival outcomes. However, national records of implants point to the series of complications connected with biomechanical flaws of the implant. These results implicate the experimental research on biomechanical properties of HRS. The aim of the research was to define the nature of cooperation between the components of hip resurfacing surgery (HRS) and the influence of the deformation of acetabulum, the size of the implant and the nature of the bone surface on the stress distribution in the acetabulum and the femoral component. The calculations were run with the use of the finite element method (FEM), using the ANSYS bundle for this purpose. Four decrete models of the studied system were made: a model with the elements of the system connected with glue, a perfect spherical model with cooperating surfaces, a model reflecting an elliptical deformation of the acetabulum, and a model with different sizes of the implant. The results indicate that the stress values obtained for models with the ideally spherical acetabulum cannot cause significant deformation of cooperating implants. In the case of loads of the elliptically deformed acetabulum significant point stress concentrations can be observed in the spots of joint. The size of the acetabular and femoral components of HRS has influence on the stress concentration on the internal surface of the acetabulum as well as in the bone tissue surrounding the madrel of the femoral component. Moreover, physical properties of the base surface surrounding the HRS components have influence on the size of stress in the acetabulum and the femoral component.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 4; 35-41
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Results and biomechanical consideration of treatment of congenital lower limb shortening and deformity using the Ilizarov method
Autorzy:
Morasiewicz, P.
Morasiewicz, L.
Stępniewski, M.
Orzechowski, W.
Morasiewicz, M.
Pawik, Ł.
Wrzosek, Z.
Dragan, S.
Powiązania:
https://bibliotekanauki.pl/articles/307355.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bone elongation
congenital deformity
hybrid external fixator
Ilizarov external fixator
wydłużenie kości
stabilizator zewnętrzny Ilizarowa
biomechanika
deformacja
Opis:
One of the applications of the Ilizarov apparatus is the correction of congenital shortening and deformities. Ilizarov external fixator produces biomechanical structure with surrounding tissue, which is the reason why very important is correct stability of fixator. Large distraction in the case of high value of lengthening, and large deformity corection result in shear stresses that occur additionally in the regenerate, which can potentially lead to damage of the regenerating nutritive microcirculation of bone tissue and bone fragment displacements. Our objective was to assess the results of the Ilizarov method in the treatment of congenital shortening taking into account treatment strategy and the size of the axis of lengthening and correction. Our research problems include presenting the effects of biomechanics of musculoskeletal deformations on treatment results, presenting complications and their treatment. Between 1989 and 2009, 62 patients underwent surgery to correct congenital lower limb deficiencies at our Clinic; 33 patients were followed-up. In total, there were 70 surgeries (2.12/patient). Axial correction was performed in 26 patients (78.79%). Average age at the start of the treatment was 15.58 years. Mean follow-up was 8.58 years. Mean lengthening per surgery was 3.17 cm with the lengthening index of 50.7 day/cm. Results were very good for 23 patients, good for 7 patients, satisfactory for 3 patients. Complications appeared in 24 patients, problems occurred in 74.42% of the cases, obstacles in 4.65% of cases, and true complications in 20.93% of the cases. The best results were achieved in the treatment of patients with two-stage and two-segment lengthening with a total elongation of less than 7 cm, and without correction of the axis. Congenital shortening of the lower limb should be treated comprehensively because the shortening applies to all segments, and disturbs biomechanics of all lower limb. In the case of axial correction and large amount of elongation high soft tissue forces counteract the distraction forces. Hybrid construction may help to shorten treatment time, increase fixator stability and decrease rate of complications. We suggest use of hybrid Ilizarov fixator, especially when large elongation and axis corection are planned.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 1; 133-140
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary evaluation of selected biologic properties of TiO2 and SiO2 layers on metallic substrates
Autorzy:
Urbański, W.
Dragan, S.
Gębarowska, E.
Dzięgiel, P.
Krzak-Roś, J.
Miller, M.
Pezowicz, C.
Będziński, R.
Powiązania:
https://bibliotekanauki.pl/articles/284506.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
sol-gel coating
fibroblast
cytotoxicity
orthopaedic implant
Opis:
Despite of applying modern biomaterials during constructing long term orthopaedic implants, in clinical practice there are still present wide range of complications, particularly concerning matter of implant - tissue interactions. Since interaction between implant and living tissue depends mainly on biomaterial surface features, we decided to modify orthopaedic alloys to improve their biological properties. The object of this experiment was in vitro evaluation of selected biological properties, particularly cytotoxicity of titanium alloy and 316L stainless steel substrates coated with SiO2 or TiO2 thin films. The coatings were synthesized by sol-gel method. Each samples was placed into mouse fibroblast culture. The cultures in presence of tested materials were maintained for three days. We found no distinct toxic effect of tested biomaterials. We noticed increase of fibroblast proliferation in cultures with uncoated titanium and particularly SiO2 coated titanium plates.
Źródło:
Engineering of Biomaterials; 2010, 13, no. 96-98; 129-133
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies