Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Das, S." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Dielectric Permittivity and Viscoelastic Measurements οf Two Tricomponent Mixtures Consisting οf Laterally Fluorinated Terphenyl Derivatives
Autorzy:
Basak, S.
Dasgupta, P.
Das, B.
Das, M.
Dabrowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1400143.pdf
Data publikacji:
2013-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.30.-v
78.20.Fm
87.19.rd
87.19.rf
83.60.Bc
Opis:
Two tricomponent room temperature nematic eutectic mixtures ABC and ABD with laterally fluorinated constituents A and B were prepared as base mixtures for vertically aligned mode LCD's. The physical properties of these mixtures viz. birefringence, dielectric anisotropy, bend elastic constant, relaxation time and rotational viscosities were determined in order to compare with the optimum values required to achieve the target specifications of VA mode materials. The dielectric anisotropy, Δ ε, and optical birefringence, Δ n, of these mixtures were found to be in the range of (-1.3 to -1.4) and (0.13 and 0.14), respectively, at around 20°C. The figure of merit for the ABD mixture has been found to be higher than that of ABC mixture throughout the entire temperature range. The pretilt angle effect in the physical parameters has also been studied. At T=20°C, the response time decreases to 25% and 35% for mixture ABC for 2° and 5° pretilt respectively in comparison to zero pretilt. On the other hand, at the same temperature for the ABD mixture these values are reduced by 16% and 35%, respectively.
Źródło:
Acta Physica Polonica A; 2013, 123, 4; 714-719
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Orientational Order Parameters of Two Tri-Component Mixtures from Optical Birefringence and X-Ray Diffraction Measurements
Autorzy:
Basak, S.
Dasgupta, P.
Das, B.
Das, M.
Dabrowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1492775.pdf
Data publikacji:
2011-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.05.cp
61.30.-v
42.70.Df
Opis:
Two tri-component mixtures as base mixtures for vertically aligned mode LCD's were prepared. The eutectic compositions were theoretically estimated and experimentally verified from differential scanning calorimetry studies. A room temperature nematic mixture with fairly broad operating range emerged from each of the tri-component mixtures. The optical birefringence of these mixtures at the eutectic composition was measured as a function of temperature. X-ray diffraction measurements were done on these mixtures to obtain the orientational order parameters as a function of temperature. The order parameter values were also determined from birefringence measurements and the results were compared with mean field theory. Structural parameters like intermolecular distance and apparent molecular length have also been determined.
Źródło:
Acta Physica Polonica A; 2011, 120, 6; 1037-1042
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal/reduction of organic pollutants from aqueous environment
Usunięcie/redukcja zanieczyszczeń organicznych ze środowiska wodnego
Autorzy:
Sarkar, M.
Das, M.
Manna, S.
Acharya, P.
Powiązania:
https://bibliotekanauki.pl/articles/1826240.pdf
Data publikacji:
2003
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zanieczyszczenia organiczne wody
adsorpcja siarczanu
jakość wody
Opis:
The problem of considerable contamination of the aqueous environment with organic pollutants still requires the development of quick and simple methods for the removal, separation and determination of these compounds. The main classes of organic compounds that most of the industries use and discharge into the effluents are phenol, surfactant and dye. All these compounds are troublesome contaminants which pose not only to toxicity and health hazards but also hamper the environmental treatment processes. In chemical industry phenol is considered as an important starting materials for numerous intermediates and finished products. It is used for the production of a wide range of consumer goods and process materials ranging from adhesives, resins, emulsifiers and detergents, plasticizers, herbicides, dyes and flavors. The worldwide production of phenol is estimated to be 5 million tons per year. Phenol and its analogues are known to be toxic to microbes. The sign of acute illness induced by phenols in experimental animals as well as in humans is known. Continuous ingestion of phenol for a prolonged period of time causes mouth sore, diarrhoea, excretion of dark urine and impaired vision at concentration levels 10÷240 ppm. Lethal blood concentration for phenol is around 1.3 g/L. phenols are toxic to several biochemical functions and to fish life. It acts as a substrate inhibitor in the bio-transformation. World Health Organization (WHO) prescribed a concentration 1 ppb as the guideline concentration in drinking water [1]. Disposal of dyeing industry waste water pose one of the major problem, because such effluents contain a number of contaminants including acid or base, dissolve solids, surfactants and color. Out of these, color is the first contaminant to be recognized because it is visible to human eye. The dye causes the harmful action to various aquatic lives. As it is resistant to light it protects the sunlight from penetrating through it and reduces the aesthetic quality of water. Possible methods of color removal include chemical oxidation, froth flotation, coagulation, adsorption, etc. The anionic surfactants generally are removed by the chemical precipitation, foam separation, ultrafiltration and adsorption. Possible means of removal of phenols from waste water include ion exchange, reverse osmosis, chemical oxidation, precipitation, distillation, gas stripping, solvent extraction, adsorption or bio remediation. Removal of SDS, 4-nitrophenol and malachite green by activated carbon is an efficient and acceptable process. But the cost of operation is very high. Therefore, the present study is undertaken using fly ash as the adsorbent. Compared to activated carbon the efficiency of removal is less in case of 4-nitrophenol and SDS. But fly ash, being a waste material, is very cheap; only the carrying cost from the site of thermal plant to the laboratory is needed. Thus the use of fly ash in removing organic pollutants appears to be a cost viable. The simplicity of the technique makes the process quite acceptable.
Obecność organicznych zanieczyszczeń w strumieniu ścieków znacznie degraduje jakość wody. Zarówno własność estetyczne jaki i organizmy wodne stają wobec niebezpieczeństwa związanego z taką degradacją. Usunięcie zanieczyszczeń organicznych szczególnie za pomącą prostych i tanich metod jest wyzwaniem dla naukowców zajmujących się środowiskiem. Obecnie komunikaty naukowe mówią o możliwości zastosowania popiołów lotnych, odpadów stałych powstających w elektrociepłowniach, w usuwaniu albo redukcji ładunków niektórych organicznych zanieczyszczeń. W referacie przedstawiono wyniki badań nad adsorpcją siarczanu dodecylu sodu SDS (anionowy środek powierzchniowo czynny), zieleni malachitowej MG oraz 4-nitrofenolu na popiołach lotnych. Usunięcie SDS, 4-nitrofenolu i zieleni malachitowej na węglu aktywnym jest skutecznym i zadowalającym procesem. Ale koszt tej operacji jest bardzo wysoki. Dlatego, przedsięwzięto obecne badania używając popiołów lotnych jako substancji adsorbująca. W porównaniu do węgla aktywnego efektywność usunięcia na popiołach lotnych jest mniejsza w przypadku 4-nitrofenolu i SDS. Ale popioły lotne, będąc odpadem, są bardzo tanie. W ten sposób użycie popiołów lotnych w usuwaniu organicznych zanieczyszczeń okazuje się być wykonalne pod względem kosztów. Proces jest wykonalny kinetycznie i termodynamicznie, prosty w wykonaniu i tani.
Źródło:
Rocznik Ochrona Środowiska; 2003, Tom 5; 79-86
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal selection of dental implant for different bone conditions based on the mechanical response
Autorzy:
Roy, S.
Das, M.
Chakraborty, P.
Biswas, J. K.
Chatterjee, S.
Khutia, N.
Saha, S.
Roychowdhury, A.
Powiązania:
https://bibliotekanauki.pl/articles/307549.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wytrzymałość kości
implanty stomatologiczne
analiza FEM
pacjent
bone condition
porous dental implant
FE Analysis
patient specific
Opis:
Bone quality varies from one patient to another extensively; also, Young’s modulus may deviate up to 40% of normal bone quality, which results into alteration of bone stiffness immensely. The prime goal of this study is to design the optimum dental implant considering the mechanical response at bone implant interfaces for a patient with specific bone quality. Method. 3D model of mandible and natural molar tooth were prepared from CT scan data while, dental implants were modelled using different diameter, length and porosity and FE analysis was carried out. Based on the variation in bone density, five different bone qualities were considered. First, failure analysis of implants, under maximum biting force of 250N had been performed; next, the implants, those survived were selected for observing the mechanical response at bone implant interfaces under common chewing load of 120N. Result. Maximum Von Mises stress did not surpass the yield strength of the implant material (TiAl4V). However, factor of safety of 1.5 was considered and all but two dental implants survived the design stress or allowable stress. Under 120N load, distribution of Von Mises stress and strain at the bone-implant interface corresponding to the rest of the implants for five bone conditions were obtained and enlisted. Conclusion. Implants, exhibiting interface strain within 1500-3000 microstrain range show the best bone remodelling and osseointegration. So, implant models, having this range of interface strains were selected corresponding to the particular bone quality. A set of optimum dental implants for each of the bone qualities were predicted.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 11-20
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies