Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "hip joint" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Develoment of a physiognomic hip joint replacement
Autorzy:
Sykora, J.
Konvickova, S.
Daniel, M.
Powiązania:
https://bibliotekanauki.pl/articles/285266.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
hip joint replacements
UHMWPE
biomaterials
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 17
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of patient-specific model scaling on hip joint reaction force in one-legged stance – study of 356 hips
Autorzy:
Hornova, J.
Kralj-Iglič, V.
Pedersen, D. R.
Daniel, M.
Powiązania:
https://bibliotekanauki.pl/articles/951837.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw biodrowy
scaling
radiogram
obciążenie połączenia
hip joint
joint load
Opis:
Estimation of hip joint loading is fundamental for understanding joint function, injury and disease. To predict patientspecific hip loading, a musculoskeletal model must be adapted to the patient’s unique geometry. By far the most common and cost effective clinical images are whole pelvis plain radiographs. This study compared the accuracy of anisotropic and isotropic scaling of musculoskeletal model to hip joint force prediction by taking patient-specific bone geometry from standard anteroposterior radiograms. Methods: 356 hips from 250 radiograms of adult human pelvis were analyzed. A musculoskeletal model was constructed from sequential images of the Visible Human Male. The common body position of one-legged stance was substituted for the midstance phase of walking. Three scaling methods were applied: a) anisotropic scaling by interhip separation, ilium height, ilium width, and lateral and inferior position of the greater trochanter, b) isotropic scaling by pelvic width and c) isotropic scaling by interhip separation. Hip joint force in one-legged stance was estimated by inverse static model. Results: Isotropic scaling affects all proportions equally, what results in small difference in hip joint reaction force among patients. Anisotropic hip scaling increases variation in hip joint force among patients considerably. The difference in hip joint force estimated by isotropic and anisotropic scaling may surpass patient’s body weight. Conclusions: Hip joint force estimated by isotropic scaling depends mostly on reference musculoskeletal geometry. Individual’s hip joint reaction force estimation could be improved by including additional bone geometrical parameters in the scaling method.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 4; 103-108
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies