Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dust exposure" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Indoor allergens in settled dust from kindergartens in city of Łódź, Poland
Autorzy:
Cyprowski, Marcin
Buczyńska, Alina
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2179064.pdf
Data publikacji:
2013-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
indoor allergens
settled dust
environmental exposure
allergen transportation
kindergartens
children
Opis:
Objectives: The main objective of the study was to determine the levels of house dust mite (Der p1), dog (Can f1), cat (Fel d1) and cockroach (Bla g2) allergens in kindergartens localized in an urban agglomeration. Material and Methods: A quantitative analysis of allergens was carried out in settled dust samples collected by vacuuming the floor surface in three kindergartens (N = 84) and children's clothing (N = 36). The samples were collected in springsummer and autumn-winter periods as well as at the beginning and end of the week. The allergen dust concentration was determined by enzyme-linked immunoenzymatic assay (ELISA). Results: The mean geometric concentrations (±geometric standard deviations) of allergens Der p1, Can f1, Fel d1 and Bla g2 determined in kindergartens were: 0.02±3.21 μg/g of dust; 0.97±4.49 μg/g of dust; 0.30±4.43 μg/g of dust and 0.01±3.08 μg/g of dust, respectively. Younger classrooms (children aged from 3 to 4 years) were characterized by almost twice higher mean concentration of allergen Fel d1, as compared to older classrooms (children aged from 5 to 6 years) (p < 0.05). A significant impact of seasonality on the level of dog allergen Can f1 was found (p < 0.05). No significant weekly variation was found in average concentrations of the allergens. Children who had a dog and/or cat at home were characterized by high concentrations of allergens Can f1 and Fel d1 on their clothes (59.2±5.39 μg Can f1/g of dust; 3.63±1.47 μg Fel d1/g of dust), significantly higher than concentrations of allergens in children who did not have any pets (p < 0.001). Conclusions: Special attention should be paid to keeping the kindergarten rooms tidy and clean and to an appropriate choice of furnishings and fittings which would prevent the proliferation of the house dust mite and accumulation of allergens.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 6; 890-899
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Endotoxin exposure and changes in short-term pulmonary function among sewage workers
Autorzy:
Cyprowski, Marcin
Sobala, Wojciech
Buczyńska, Alina
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2177186.pdf
Data publikacji:
2015-06-25
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
sewage workers
endotoxin exposure
inhalable dust
smoking
lung function
regression analysis
Opis:
Objectives The inhaled endotoxin is considered as a causative factor in the process of acute bronchial obstruction, which can be measured by a decrease in forced expiratory volume in 1 s (FEV₁). The aim of this study was to assess endotoxin exposure among sewage treatment plant workers (STPW) and its effect on across-shift changes in respiratory airflow. Material and Methods A group of 78 STPW from a large sewage treatment plant was studied. Inhalable dust for endotoxin assessment was collected using personal aerosol samplers. Endotoxin was assayed with the kinetic, chromogenic Limulus amebocyte lysate test. Across-shift spirometric measurements were performed on Mondays, after 2-days absence from work, with the use of portable spirometer. The forced vital capacity (FVC), and FEV₁ parameters were analyzed. Multifactor regression modeling was performed to determine parameters significantly associated with endotoxin exposure. Results The concentration of inhalable dust and endotoxin ranged from 0.01–1.38 mg/m³ and 0.68–214 endotoxin units per cubic meter of air (EU/m³), respectively. Endotoxins were characterized with the skewed distribution (arithmetic mean (AM) = 38.8 EU/m³, geometric mean (GM) = 15.4 EU/m³, geometric standard deviation (GSD) = 4.21). Through the use of multifactor analysis, which excluded the main confounders (inhalable dust and smoking habit) it was found that, despite low levels of endotoxin, it had significant impact on the observed across-shift decline in FEV₁ (p = 0.044). For this parameter, the regression slope was additionally calculated (r = –0.017, p = 0.071). Conclusions Relatively low levels of endotoxin among sewage treatment plant workers may cause small, but significant across-shift declines in FEV₁. The observed relationship was independent of organic dust concentrations and smoking habit. The respiratory protection should be provided for STPW.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 5; 803-811
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to culturable and total microbiota in cultural heritage conservation laboratories
Autorzy:
Górny, Rafał L.
Harkawy, Aleksander S.
Ławniczek-Wałczyk, Anna
Karbowska-Berent, Joanna
Wlazło, Agnieszka
Niesler, Anna
Gołofit-Szymczak, Małgorzata
Cyprowski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2177074.pdf
Data publikacji:
2015-10-23
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
settled dust
bioaerosol
conservation laboratory
cultural heritage
occupational exposure
microbial hazards
Opis:
Objectives To date, the scientific source materials usually focus on microbial contamination of the museum or library collections themselves, while the exposure of persons who professionally deal with this type of objects in cultural heritage conservation laboratories is ignored. Material and Methods The study was carried out in 9 naturally ventilated conservation laboratories with no history of water damage. Viable (understood as culturable) bioaerosol stationary samples were collected in both outdoor and indoor environments using 6-stage Andersen impactor. Simultaneously, stationary and personal indoor bioaerosol measurements were carried out using both Gesamtstaubprobenahme an der Person (GSP) and Button filter samplers. These measurements were complemented by evaluation of microbial content in the dust settled on conserved works of art. All impactor, filter, and settled dust samples were quantitatively examined to obtain viable and total concentrations of bacteria and fungi. All isolated microbial strains were taxonomically identified. Results At workplaces, the concentrations of viable microorganisms in air were below 2000 cfu/m³ and accounted for not more than 5.5% of total microbiota. The study showed that quantitative assessment of viable bioaerosol can be made with an Andersen impactor as well as by using Button and GSP filter samplers, irrespective of whether they are applied for personal or stationary measurements. Compared to the impactor, however, the use of filter samplers for microbial contamination monitoring substantially limits the scope of qualitative information which can be obtained. Size distribution analysis revealed that the largest “load” of microorganisms can penetrate into the respiratory tract between the trachea and terminal bronchi, and thereby may be responsible for allergic inflammations in exposed workers. Conclusions The precise assessment of microbial hazards in conservation laboratories should comprise control of both viable and total particle counts. The hermetization of such workplaces and control of relative humidity should be implemented and maintained to assure proper hygienic conditions.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 2; 255-275
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szkodliwe czynniki biologiczne w zakładach termicznego unieszkodliwiania odpadów komunalnych
Harmful biological agents in municipal waste thermal treatment plants
Autorzy:
Cyprowski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2162594.pdf
Data publikacji:
2019-02-28
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
narażenie zawodowe
odpady komunalne
spalarnie odpadów
pył organiczny
bakterie przenoszone drogą powietrzną
grzyby przenoszone drogą powietrzną
occupational exposure
municipal waste
waste incinerations
organic dust
airborne bacteria
airborne fungi
Opis:
Składowanie odpadów komunalnych w specjalnie wyznaczonych do tego miejscach przez wiele lat stanowiło podstawową metodę ich zagospodarowania – obecnie preferowana jest utylizacja termiczna. Ocena warunków pracy w spalarniach odpadów komunalnych jest utrudniona z powodu zmienności i złożoności zanieczyszczeń emitowanych w wyniku spalania. Autorzy prac opisujących ten problem przez wiele lat koncentrowali się przede wszystkim na zanieczyszczeniach chemicznych wewnątrz badanych zakładów oraz zanieczyszczeniach emitowanych do powietrza atmosferycznego. Oszacowano, że stężenie pyłu organicznego na stanowiskach pracy wynosiło 0,1–14 mg/m3. Udowodniono, że pył ten jest nośnikiem wielu różnych drobnoustrojów, w tym bakterii, grzybów oraz promieniowców mezofilnych i termofilnych, a także adenowirusów i wirusa torque teno. W strefie oddychania pracowników na stanowiskach pracy stwierdzono także obecność endotoksyn bakteryjnych w stężeniu nawet 50 000 EU/m3, które mogą istotnie wpływać na występowanie reakcji prozapalnych w płucach oraz toksycznego zapalenia płuc. Czynniki biologiczne powinny być uwzględniane w ocenie ryzyka zawodowego jako czynniki szkodliwe występujące w tym środowisku, a szczegółowe scharakteryzowanie narażenia oraz skutków zdrowotnych wynikających z kontaktu z nimi powinno być kontynuowane w jeszcze szerszym niż dotychczas zakresie. Med. Pr. 2019;70(1):99–105
Solid waste storage in specially designated areas – landfills – has been the basic method of municipal solid waste disposal management for many years. However, thermal treatment is the currently preferred method of solid waste disposal. Hygienic assessment of working conditions in municipal waste incineration plants is hindered due to the variability and complexity of pollutants emitted during the combustion process. For many years studies describing this problem have focused mainly on chemical pollution inside the plants as well as emitted into the atmosphere. Available data indicates the presence of organic dust at workplaces in the range 0.1–14 mg/m3. It has been proven that it is a carrier of a wide spectrum of microorganisms, including bacteria, fungi and both mesophilic and thermophilic actinomycetes as well as adenoviruses and torque teno virus (TTV). In the air, at workplaces, bacterial endotoxins have also been found in concentrations reaching even 50 000 EU/m3, which may significantly affect the occurrence of pro-inflammatory reactions in the lungs as well as toxic pneumonitis. Biological agents should be taken into account in the occupational risk assessment for harmful agents present in this environment, and an in-depth characterization of exposure and health effects resulting from contact with these agents should be continued to an even greater extent than before. Med Pr. 2019;70(1):99–105
Źródło:
Medycyna Pracy; 2019, 70, 1; 99-105
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies