Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "domestic" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
The efficiency of pollutant elimination in the Dobra treatment plant
Autorzy:
Nowak, J.
Chmielowski, K.
Chmielowska, B.
Bedla, D.
Powiązania:
https://bibliotekanauki.pl/articles/101622.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage treatment plant
domestic sewage
SBR
Opis:
This study was aimed to conduct an analysis of the efficiency of pollutant elimination in the Dobra treatment plant, which operates based on the SBR reactor. The object purifies domestic sewage and pre-treated industrial sewage from a slaughterhouse within the Dobra municipality. The source material for the analysis comprised the values of pollution indicators: BOD5 , CODCr, total suspended solids (TTS) in raw sewage (19 samples) and treated sewage (34 samples). The results of chemical analyses were obtained in the period 2007-2014. The results were compared with the limit values imposed by the Regulation (2014). The coefficient of reliability of the treatment plant was also calculated in this study. The average efficiency of pollutant elimination in the treatment plant was: BOD5 - 98.6%, CODCr - 94.9%, total suspended solids - 97.6%. These results demonstrate that the studied facility operates flawlessly and the treatment efficiency is high. On the other hand, the reliability coefficient values indicate that the operation of this object is unstable.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, III/1; 737-747
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmienności dopływu ścieków do oczyszczalni dla aglomeracji Dębica
Analysis of sewage inflow variability to a sewage treatment plant for the agglomeration of Dębica
Autorzy:
Chmielowski, K.
Bugajski, P.
Wąsik, E.
Cupak, A.
Powiązania:
https://bibliotekanauki.pl/articles/101536.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki bytowe
dopływ ścieków
oczyszczalnia ścieków
domestic sewage
hydraulic load
sewage treatment plant
Opis:
W pracy dokonano analizy zmienności dopływu ścieków do oczyszczalni w Dębicy. W tym celu określono podstawowe statystyki opisowe dotyczące dopływu ścieków do oczyszczalni: wartość średnia (Qdśr), mediana (Mo), wartość minimalna (Qdmin), wartość maksymalna (Qdmax), odchylenie standardowe, współczynnik zmienności (Vzm), rozstęp (Ro). Określono histogram liczby dopływów ścieków do oczyszczalni dla zadanych przedziałów obserwacji. Zestawiono szczegółowe dobowe dopływy ścieków surowych do oczyszczalni w Dębicy w latach 2019-2015 na tle wartości dopuszczalnej z pozwolenia wodno-prawnego oraz wartości średniej. Zestawiono średnie dobowe wartości przepływów ścieków dla poszczególnych miesięcy roku dla okresu 2009-2015. Dokonano zestawienia średnich dobowych przepływów ścieków w poszczególnych latach badanego okresu. Zestawiono średnie dobowe wartości przepływów ścieków w poszczególnych dniach tygodnia dla okresu 2009-2015. Ponadto pozyskano dane opadowe ze stacji w Tarnowie (najbliższa stacja opadowa od badanego obiektu) i na tej podstawie określono średnie wartości dobowego opadu atmosferycznego dla poszczególnych miesięcy w latach 2009-2015. Następnie dokonano podziału dób okresu badawczego ze względu na wielkość opadów atmosferycznych na 7 zasadniczych grup. Określono wpływ opadów atmosferycznych na ilość ścieków dopływających do badanego obiektu. Stwierdzono znaczący wpływ opadów atmosferycznych na dopływ ścieków do oczyszczalni w Dębicy.
The paper analyzes the variability of sewage inflow to a treatment plant in Dębica. For this purpose, the following basic descriptive statistics of the sewage inflow to the treatment plant were determined: mean value (Qdm), median (Mo), minimum value (Qdmin), maximum value (Qdmax), standard deviation, coefficient of variation (Vzm), range (Ro). Histogram of a number of sewage inflows to the treatment plant for the specified observation intervals was determined. Detailed diurnal raw sewage inflows to the treatment plant in Dębica were summarized for the period of 2009-2015 compared to the limit value specified by the water-legal permit and the to the mean value. Mean diurnal sewage flow values for individual months from the period of 2009-2015 were also summarized. Mean diurnal sewage flows in individual years of the studied period, as well as mean diurnal sewage flow values in each day of the week were compared. Moreover, runoff data were obtained from the Tarnów station (the nearest rainfall station to the studied facility) and on this basis mean values of diurnal precipitation for individual months in the period of 2009-2015 were determined. Subsequently, the days of the study period were divided into 7 major groups based on the amount of atmospheric precipitation. The effect of precipitation on the amount of sewage flowing into the studied facility was examined and it was found that the precipitation has a significant effect on the sewage inflow to the treatment plant in Dębica.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 589-603
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of the quality of sewage discharged from selected agglomeration sewerage systems
Analiza porównawcza jakości ścieków odpływających z wybranych aglomeracji kanalizacyjnych
Autorzy:
Chmielowski, K.
Bugajski, P.
Kaczor, G. B.
Powiązania:
https://bibliotekanauki.pl/articles/947134.pdf
Data publikacji:
2016
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
agglomeration
domestic sewage
sewage composition
sewerage system
aglomeracja
skład ścieków
system kanalizacyjny
ścieki bytowe
Opis:
The study provides a comparative analysis of the quality of sewage discharged from selected sewerage systems. The analyzed data were collected from 10 agglomeration sewerage systems discharging sewage into collective wastewater treatment plants (WTP). The investigated pollution indicators included BOD5, CODCr, total suspended solids and biogenic indicators such as total nitrogen and total phosphorus. These results were compared with the outcomes reported in commonly available research papers on sewage disposal. Considering the concentration of individual pollution indicators, more detailed categories of sewage pollution were adopted in this work. The sewage was divided into five basic groups: I – highly concentrated, II – concentrated, III – moderately concentrated, IV – diluted, and V – highly diluted. The sewage categories accounted for the following pollution indicators: BOD5, CODCr, total suspended solids, total phosphorus and total nitrogen. Mean BOD5, CODCr and total suspended solids in raw sewage were higher than average values reported in the referenced literature. Contrary to that, concentration of total phosphorus in raw sewage was significantly lower than reported by other authors. The outcomes of this study suggest that the predictions concerning pollution degree of raw sewage made at WTP design stage should not be based exclusively on general values provided in literature reports.
W pracy przedstawiono analizę porównawczą jakości ścieków odpływających wybranymi systemami kanalizacyjnymi. Badania przeprowadzono w dziesięciu wybranych aglomeracjach kanalizacyjnych odprowadzających ścieki do oczyszczalni zbiorczych. Analizie poddano podstawowe wskaźniki zanieczyszczenia ścieków (BZT5, ChZTCr, zawiesina ogólna) oraz biogenne (azot ogólny i fosfor ogólny). Porównano średnie wartości poszczególnych wskaźników zanieczyszczenia ścieków odpływających z wybranych aglomeracji kanalizacyjnych. Uzyskane wyniki porównano z wartościami zestawionymi w ogólnodostępnej literaturze związanej z tematyką unieszkodliwiania ścieków. Do badań przyjęto podział ścieków ze względu na koncentrację poszczególnych wskaźników zanieczyszczenia. Ścieki podzielono na pięć zasadniczych grup (I – ścieki bardzo stężone, II – ścieki stężone, III – ścieki średnio stężone, IV – ścieki rozcieńczone, V – ścieki bardzo rozcieńczone). Uzyskane średnie wartości BZT5, ChZTCr i zawiesiny ogólnej w ściekach surowych były większe od wartości średnich przedstawianych w analizowanej literaturze. Natomiast stężenie fosforu ogólnego w ściekach surowych było zdecydowanie mniejsze niż podają inni autorzy. Wyniki przeprowadzonych badań wskazują, że podczas projektowania oczyszczalni ścieków należy zachować pewną ostrożność w prognozowaniu stężeń zanieczyszczeń w ściekach surowych wyłącznie na podstawie uogólnionych wartości podawanych w literaturze.
Źródło:
Journal of Water and Land Development; 2016, 30; 35-42
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of precipitation on the amount and quality of raw sewage entering a sewage treatment plant in Wodzisław Śląski
Analiza wpływu opadów atmosferycznych na ilość i jakość ścieków surowych dopływających do oczyszczalni w Wodzisławiu Śląskim
Autorzy:
Chmielowski, K.
Bugajski, P. M.
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/292636.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
accidental waters
domestic sewage
sewage quality
precipitation
jakość ścieków
opad atmosferyczny
ścieki bytowe
wody przypadkowe
Opis:
The study presents the effects of precipitation on the amount and quality of raw sewage entering a sewage treatment plant in Wodzisław Śląski. It covers a six-year period between January 2010 and December 2015. The research period was divided into seven classes of precipitation intensity. The classes were characterized for their basic descriptive statistics of the raw sewage entering the investigated sewage treatment plant (STP). Data obtained from the collected material and derived from an analysis indicated a considerable influence of precipitation on the amount of sewage entering the investigated facility. Mean amount of sewage entering the STP was by 10.5% (884.9 m3∙d–1) greater in B class and by 69.6% (6,153.9 m3∙d–1) greater in G class than during dry weather. Individual classes of precipitation intensity were compared for their mean values of raw sewage contamination. Precipitation intensity was found to significantly affect concentrations of the investigated parameters of raw sewage contamination. Basic parameters of sewage contamination (BOD5, CODCr, total suspended solids) were determined and their basic descriptive statistics, such as median, mean, minimum and maximum value, standard deviation and coefficient of variation were calculated.
W pracy przedstawiono analizę wpływu opadów atmosferycznych na ilość i jakość ścieków surowych dopływających do oczyszczalni w Wodzisławiu Śląskim. Badania przeprowadzono w okresie od stycznia 2010 r. do grudnia 2015 r. (6 lat). Dokonano podziału okresu badawczego na 7 grup intensywności natężenia opadu atmosferycznego. Dla analizowanych grup określono podstawowe statystyki opisowe wartości dopływu ścieków surowych do oczyszczalni. Na podstawie zebranego materiału i przeprowadzonej analizy stwierdzono istotny wpływ opadu atmosferycznego na ilość ścieków dopływających do badanego obiektu. Średni przyrost ilości dopływających ścieków w stosunku do dopływu ścieków w okresie bezdeszczowym wyniósł od 10,5% (884,9 m3∙d–1) dla grupy „B” do 69,6% (6 153,9 m3∙d–1) dla grupy „G”. Dokonano porównania średnich wartości wskaźników zanieczyszczenia ścieków surowych w poszczególnych grupach intensywności opadu atmosferycznego. Stwierdzono istotny wpływ natężenia opadu atmosferycznego na stężenia badanych wskaźników zanieczyszczenia ścieków surowych. Określono podstawowe wskaźniki zanieczyszczenia ścieków (BZT5, ChZTCr, zawiesina ogólna). Określono podstawowe statystyki opisowe wartości badanych wskaźników: mediana, wartość średnia, minimalna, maksymalna, odchylenie standardowe, współczynnik zmienności.
Źródło:
Journal of Water and Land Development; 2017, 34; 85-93
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies