Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "osteosynthesis" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Osteosynthesis on the basis of resorbable polymers implants - selected problems
Autorzy:
Będziński, R.
Chłopek, J.
Frątczak, R.
Kotela, I.
Powiązania:
https://bibliotekanauki.pl/articles/285918.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteosynthesis
resorbable polymers
biomaterials
Opis:
Use of bioresorbable materials in bone surgery opens up new possibilities in treatment of injuries and orthopaedic illnesses. Lack of necessity for implant removal surgery enables faster treatment and substantial reduction in costs of treatment. In recent years, these advantages have caused growing interest in materials of this type. It must be noted that bioresorbable materials in most cases are based on macromolecular materials – polymers which have completely different mechanical characteristics than traditional materials used in bone surgery. Bioresorbable properties give enormous possibilities but also present difficult challenges related to construction of new types of implants based on materials of this type. Full characteristics of new materials is indispensable in construction process, especially of mechanical properties and surface properties. The latter is responsible for contact with biological environment and bioactivity is determined on the basis of hydroxyapatite precipitations amount on material surface. In case of polymer based composites, influence of phases in powder and fibre form on properties is fundamental to be proved. Addition of particle modifier into polymer matrix causes reduction in strength of polymer. This phenomenon is mostly associated with homogenic particle distribution difficult to be achieved in case of higher filler content. However biological interplay is insufficient by low filler contents. Therefore in the below presented investigations different filler contents were applied and their influence on mechanical properties was investigated to achieve compromise between mechanical properties and bioactive, antibacterial or anti-inflammatory effect of the applied particles. Acquaintance with these results allowed for elaboration of full range of material and constructive solutions for implants in bone surgery. Biodegradable biopolymers have low mechanical properties (Young’s modulus, strength, viscoelasticity). Construction process of bioresorbable implants requires to be completely changed in way of conduction. Computer simulation based investigations of stress-strain characteristics is necessary to be carried out in each stage of research. Bigger cross-sections and different shapes of implants are required to achieve suitable stiffness. Application of bone screws made of resorbable materials requires design of these elements from the bottom up. Design of optimal shape of screw thread and point of contact between screw head and bone plate is particularly important. 9 different implants were designed within the confines of conducted research – including for tibia, humerus, radius, ulna, phalanges, clavicle, calcaneus, pelvis and metatarsus. Stress values were determined in analyzed implants. Acceptable loads were determined for individual types of plate. Plates made of PLA can bear small loads and play role mainly as grasping and holding bone element. In most cases additional immobilization of operated bone is required in order to prevent plate or screw destruction. In case of stabilization function for resorbable materials – as many screws as possible are recommended – thanks to it, screws are less loaded and the plate-bone system is more immobilized.
Źródło:
Engineering of Biomaterials; 2014, 17, no. 128-129; 108
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wytrzymałość zmęczeniowa wielofunkcyjnej resorbowalnej płytki kompozytowej w symulowanych warunkach biologicznych
Fatigue strength tests of multifunctional resorbable composite plates in simulated biological conditions
Autorzy:
Gryń, K.
Szaraniec, B.
Chłopek, J.
Powiązania:
https://bibliotekanauki.pl/articles/286175.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
płytka zespalająca
implant wielofunkcyjny
symulowane środowisko biologiczne
wytrzymałość zmęczeniowa
czas życia
fixation plate
osteosynthesis
multifunctional implant
simulated biological environment
working time
fatigue strength
Opis:
Artykuł jest kolejną częścią prezentującą wyniki badań mechanicznych wielofunkcyjnych resorbowalnych płytek zespalających. Testy dotyczyły wyznaczenia wytrzymałości zmęczeniowej płytek ze-spalających w warunkach symulujących rzeczywiste warunki pracy. Określenie tego parametru, zwłaszcza w elementach poddawanych obciążeniom zmiennym w czasie, jest bardzo ważne ze względu na możliwość wystąpienia w materiale zmian strukturalnych np.: umocnienia odkształceniowego czy rozwoju defektów prowadzących do zniszczenia elementu. Materiały kompozytowe o osnowie polimerowej modyfikowane cząstkami ceramicznymi są stosunkowo czułe na tego typu obciążenia. Kolejnym aspektem, który musi być uwzględniony przy opisie i charakterystyce mechanicznej przedmiotowych implantów jest środowisko, w jakim się one docelowo znajdą. Temperatura, pH oraz skład chemiczny to czynniki bezpośrednio wpływające na sposób i tempo degradacji polimeru resorbowalnego. Degradacja z kolei wpływa na charakterystyki wytrzymałościowe osłabiając materiał. W prezentowanych badaniach zastosowano modelowe zespolenie, w którym rolę odłamów kostnych pełniły specjalnie przygotowane bloczki z PMMA, do których za pomocą śrub metalowych przymocowana była testowana płytka. Tak przygotowany układ mocowano w maszynie zmęczeniowej i poddawano cyklicznemu rozciąganiu. Zastosowano dwa warianty badania: pierwsze, gdzie modelowe zespolenie obciążano „na sucho” bez obecności płynów symulujących środowisko biologiczne; i drugi, gdzie modelowe zespolenie umieszczano w zamkniętym zbiorniku, wypełnionym płynem symulującym środowisko biologiczne. Jako medium zastosowano płyn Ringera podgrzewany do temperatury ~37°C.Na podstawie otrzymanych wyników stwierdzono, że płytki badane „na sucho”, cechowały się inną charakterystyką niż płytki wystawione na oddziaływanie symulowanego środowiska biologicznego.
The article is part of a series of publications presenting the results of mechanical tests of multi-functional resorbable fixation plates. Tests were con-ducted on prototype plates in conditions simulating natural biological environment. The examinations were meant to assess the so-called “implant working time” or fatigue strength of the fixation plates. This parameter is particularly important in the case of elements subjected to time-varying loads due to the possibility of alterations to the material structure, strain strengthening or development of defects leading to the implant failure. Composite materials consisting in a polymer matrix modified with ceramic particles are quite sensitive to variable loads. Moreover, the complex geometry of the tested plates makes them more vulnerable to destruction with the critical cross-sections located at the fixing holes. Another key aspect is the biological environment where the implants will perform their functions. The temperature, pH and chemical composition are factors directly affecting the way and rate of degradation of the resorbable polymer. Degradation affects the strength characteristics, obviously weakening the material. The tests were performed on a model composed of PMMA blocks playing the role of bones with the tested plate attached with metal screws. The model was mounted in a fatigue machine and subjected to cyclic stretching. Two variants of the examinations were performed. Firstly, the model was tested in “dry” conditions; secondly - in a closed container filled with fluids simulating the biological environment (the Ringer’s solution heated to ~37°C used as the medium). The results revealed that the plates tested in “dry” conditions were endowed with different characteristics as compared to the plates exposed to the simulated biological environment.
Źródło:
Engineering of Biomaterials; 2018, 21, 147; 21-30
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka mechaniczna wielofunkcyjnej resorbowalnej płytki kompozytowej do zespoleń kostnych
Mechanical characterization of multifunctional resorbable composite plate for osteosynthesis
Autorzy:
Gryń, K.
Szaraniec, B.
Morawska-Chochół, A.
Chłopek, J.
Powiązania:
https://bibliotekanauki.pl/articles/284036.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteosynteza
zespolenie kostne
płytki zespalające
płytki kompozytowe
płytki wielofunkcyjne
polimer resorbowalny
polilaktyd
hydroksyapatyt
fosforan wapnia
własności mechaniczne
parametry wytrzymałościowe
osteosynthesis
bone plate
composite plates
multifunctional plates
resorbable plates
poly-lactide
hydroxyapatite
tricalcium phosphate
mechanical characterisation
durability
Opis:
W artykule przedstawiono badania mechaniczne prototypowego wszczepu do zespoleń kostnych w postaci resorbowalnej wielofunkcyjnej czterootworowej płytki w kształcie litery I. Testy dotyczyły gotowych implantów w symulowanych warunkach pracy, a nie normatywnych próbek (wiosło, belka) dlatego przygotowano odpowiedni modelowy schemat badawczy implantu. Składał się on z dwóch bloczków imitujących odłamy kostne, połączonych za pomocą badanej płytki, który był poddawany testom mechanicznym w izolowanych stanach naprężeniowo-odkształceniowych (jednoosiowe rozciąganie, trójpunktowe i jednostronne zginanie). Badano płytki wykonane z dwóch odmian polimeru resorbowalnego (poli-L-laktydu) oraz dwa rodzaje kompozytu, w których osnowę stanowiła jedna z odmian polimeru, a fazą modyfikującą była mieszanina mikrometrycznego proszku ortofosforanu trójwapnia i nanometrycznego hydroksyapatytu. Badano także wpływ geometrii płytek na charakterystyki mechaniczne. Na podstawie przeprowadzonych badań stwierdzono wyraźny wpływ dodatków ceramicznych na zmianę parametrów wytrzymałościowych płytek wykonanych z różnych materiałów. W przypadku polilaktydu z dopuszczeniem medycznym zaobserwowano spadek wytrzymałości przy jednoczesnym podniesieniu modułu Younga E. Ponadto geometria implantu, czyli w badanym przypadku lokalizacja żeberka wzmacniającego, wpływała na uzyskane wyniki. Lepszymi parametrami cechowały się płytki z żeberkiem wzmacniającym na górnej stronie płytki. Ponadto podczas testów zginania stwierdzono, że przy tego rodzaju geometrii płytki pęknięcie lokalizuje się poza przekrojem krytycznym, a więc taka konstrukcja jest bardziej bezpieczna. Z grupy przebadanych prototypów, jako najlepsze, wybrano płytki kompozytowe PL38/TCP/HAp, wykonane z poli-L-laktydu medycznego, modyfikowanego mieszaniną proszków ceramicznych z żeberkiem wzmacniającym na powierzchni górnej. Mogą one znaleźć zastosowanie w osteosyntezie, w miejscach które nie są narażone na zbyt duże obciążenia mechaniczne. Do tej grupy zaliczyć można kości w obrębie twarzoczaszki oraz kości krótkie ręki. Zaleca się przy tym zastosowanie usztywniających opatrunków zewnętrznych.
The article presents the mechanical properties of prototype multifunctional four-hole, I-shaped plate made of resorbable composite and used for osteosynthesis. Multiple tests were conducted on ready-to-use implants and run in simulated real-working conditions. A special customized test stand was constructed for the sake of this research. The model of the osteosynthesis consisted of two rectangular pieces of plexiglas joined together by means of the tested plate. Durability of the physical model was mechanically assessed in static uniaxial tensile, three-point bending, one-side bending tests. Two types of resorbable polymers (poly-L-lactide) and two types of composites based on these polymers were considered. The composites were modified with a combination of two types of bioceramic: micrometric tricalcium phosphate and nanometric hydroxyapatite. The relation between the geometry of the plate and its mechanical characteristics was also investigated for all the tested materials. The test results proved that incorporation of bioceramic modifiers into the polylactide matrix influences the mechanical behaviour of the tested bone plates. The composite based on FDA approved polylactide (PL38) revealed the strength decrease while the Young modulus increased at the same time. The mechanical parameters were also dependent on the geometry of the plate (localization of a stiffening rib). Better results were obtained for the plates with a stiffening rib located on the upper side of the plate. What is more, the three-point-bending test revealed that in such a case the crack line moved away from the critical cross section, making such a plate more reliable. The best parameters were achieved for the three- -component plates (PL38/TCP/Hap) with a stiffening rib on the upper side. They can be potentially applied for osteosynthesis of the bones submitted with rather low loads, e.g. craniofacial bones, metacarpal bones or phalanges. An external stiff stabilisation (a plaster cast) is recommended as an additional support and prevention.
Źródło:
Engineering of Biomaterials; 2015, 18, 133; 22-33
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies