Tytuł:
Determination of Thevenins equivalent model at the receiving node
Określanie modelu ekwiwalentu thevenina w węźle odbiorczym
Autorzy:
Brusiłowicz, B.
Szafran, J.
Powiązania:
https://bibliotekanauki.pl/articles/410567.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Thevenin 's equivalent
stability margin
local voltage stability
Opis:
This paper presents the properties of the equivalent Thevenin's model of a network as seen from a network receiving node. Such a simplified model can be applied in protective and preventive gear installed at the considered receiving node. Thevenin's circuit can be determined either from of the power system configuration diagram or by use of algorithm based on local current and voltage phas or measurements. Local measurements are used to calculate the derivative of apparent power against the voltage dS/dV. Paper describes the dS/dV algorithm accuracy tests according to the approximate angle of the series system impedance. An important problem of the Thevenin's model updating due to the changing configuration of power system is discussed in the paper. The advantages and disadvanges of both described methods are also presented.
Artykuł przedstawia właściwości modelu Thevenina. Uproszczony model reprezentujący aktualną konfigurację systemu może mieć zastosowanie w automatyce zabezpieczeniowej oraz prewencyjnej montowanej w punkcie odbiorczym. Model Thevenina może być tworzony przy użyciu dwóch metod: korzystając z informacji o pełnej konfiguracji systemu oraz z algorytmu wyliczającego parametry modelu na podstawie pomiarów lokalnych fazorów napięć i prądów. Korzystając z pomiarów lokalnych, wyliczana jest pochodna mocy pozornej po napięciu &S/&V. Przeprowadzono testy dokładności algorytmu dS/dV w zależności od założonego kąta impedancji systemowej. Ważnym problemem, jaki jest poruszony w artykule jest aktualizacja modelu zgodnie ze zmieniającą się konfiguracją systemu elektroenergetycznego. Zmiany mogą być wywoływane zarówno stanami normalnej pracy, jak i awariami występującymi w systemie. Przedstawiono wady i zalety stosowania obu metod.
Źródło:
Present Problems of Power System Control; 2011, 1; 5-13
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence Of Transformer Tap Changer Operation On Voltage Stability
Autorzy:
Brusiłowicz, B.
Szafran, J.
Powiązania:
https://bibliotekanauki.pl/articles/410519.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
voltage stability
transformer tap changer
Opis:
The paper concerns influence of transformer tap changer regulation on secondary voltage level and voltage stability margin of receiving node. At the beginning there are presented general information about voltage stability and tap changer. Voltage value of secondary terminals of transformer can be regulated using tap changer. This regulation also affects the calculation of Thevenin equivalent parameters seen from the secondary terminals. Changes of equivalent parameters cause a change of voltage stability conditions. Simulation studies of this influence for various types of load have been done. Selected simulation results are presented in the paper. At the end there are placed conclusions from the performed studies.
Źródło:
Present Problems of Power System Control; 2013, 4; 25-36
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Voltage and local stability margin regulation of the receiving node
Autorzy:
Brusiłowicz, B.
Szafran, J.
Powiązania:
https://bibliotekanauki.pl/articles/410539.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
local voltage stability
reactive power compensation
load shedding
transformer tap control
Opis:
Regulation methods of the receiving node voltage has been analyzed in the paper. There has been used Thevenin equivalent to develop, simulate and analyze these methods. The paper presents also an on-line method of Thevenin model parameters updating using local phasor measurements. Based on this model influence of the voltage regulation on the local stability margin of the receiving node has been analyzed. Three methods of voltage regulation: transformer tap changing, compensation of reactive power and under voltage load shedding have been examined.
Źródło:
Present Problems of Power System Control; 2012, 2; 53-63
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies