Wyszukujesz frazę "Power" wg kryterium: Wszystkie pola


Tytuł:
Technical Possibilities of Reducing the Sound Pressure Level Emitted into the Environment by a Power Transformer
Autorzy:
Borucki, S.
Boczar, T.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177473.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
corrected sound pressure level
noise
modernization
Opis:
The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.
Źródło:
Archives of Acoustics; 2011, 36, 1; 49-56
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary diagnostyczne transformatorów energetycznych z wykorzystaniem metody wibroakustycznej
Diagnostic measurements of power transformers using the vibroacoustic method
Autorzy:
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/274971.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
transformator energetyczny
diagnostyka
metoda wibroakustyczna
rdzeń
eksploatacja
power transformer
diagnostic
vibroacoustic method
core
exploitation
Opis:
Tematyka artykułu dotyczy diagnostyki i oceny stanu technicznego rdzeni transformatorów energetycznych na podstawie pomiarów wibroakustycznych wykonywanych on-line, podczas załączania jednostki. Przedstawione wyniki analizy parametrów drgań mechanicznych uzyskano podczas doświadczalnych badań laboratoryjnych na rzeczywistej jednostce transformatorowej. Pomiary i analizę drgań przeprowadzono przy zastosowaniu specjalistycznej aparatury pomiarowej firmy Brüel & Kjar - systemu Pulse Dyn-XI. W celu ukazania zmian wyznaczonych parametrów wibroakustycznych, w trakcie przeprowadzonego eksperymentu badawczego zamodelowano uszkodzenie rdzenia badanego transformatora, by następnie powiązać je z otrzymanymi wynikami wartości wskaźników wibroakustycznych.
The subject matter of this paper refers to the research work connected with diagnosis and assessment of the technical condition of power transformer cores based on on-line vibroacoustic measurements taken during switching on the unit. The analysis results of the mechanical vibration parameters presented in the paper were obtained during experimental laboratory investigations on a real transformer unit. The measurements were taken and the analysis of vibrations was carried out using a specialized measuring apparatus by Brüel & Kjar - Pulse Dyn-XI system. In order to indicate the changes of the vibroacoustic parameters determined, a defect of the core of the transformer tested was modeled during the experiment so that they might be later associated with the results of the vibroacoustic index values obtained.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 12; 110-114
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów energetycznych z wykorzystaniem metody wibroakustycznej
Diagnostics of Power Transformers Using the Vibroacoustic Method
Autorzy:
Borucki, S.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155761.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator energetyczny
drgania
rdzeń
metoda wibroakustyczna
diagnostyka
power transformer
vibration
core
vibroacoustic method
diagnostic
Opis:
Tematyka artykułu dotyczy diagnostyki rdzeni transformatorów elektro-energetycznych dużej mocy z wykorzystaniem pomiarów drgań wibroaku-stycznych. W artykule, na podstawie analizy drgań mechanicznych kadzi, dokonano oceny stanu technicznego czterech transformatorów blokowych typu TFBb 240000/400. Scharakteryzowano układ pomiarowy, który został wykorzystany podczas rejestracji sygnałów pochodzących od przenoszonych przez kadź drgań rdzenia poszczególnych jednostek. W oparciu o przyjęte w artykule wartości kryterialne podjęto próbę oceny stanu technicznego diagnozowanych urządzeń elektroenergetycznych.
During its operation a power transformer is subjected to the influence of numerous unfavourable factors which shorten its operation time and can cause unexpected disastrous failures. As far as the active part of a transformer is considered, magnetostrictic vibrations and cellulose depolymerization are the most harmful factors causing the loss of mechanical strength. Their influence results in the gradual loosening of the pressing and clamping of the core and transformer windings, which leads to the weakening of the active part mechanical construction (Fig. 1). In the electric power sector there are a few methods for detection of damages in power transformers. One of them is the vibroacoustic method which consists in measurement and analysis of vibrations of the object under study. Its application to high-power transformer diagnostics enables, first of all, assessing the technical condition of the core. Additionally, combining this method with other diagnostic methods can provide information not only on the core technical condition but also on the solid insulation properties of the device being tested [5 - 6]. In the paper the technical assessment of the condition of four unit transformers of type TFBb 240000/400 is performed basing on the analysis of mechanical vibrations of the tub. The basic technical parameters of the transformers are listed in Table 1. The measuring system used for recording the signals coming from the core vibrations of the particular units and transferred by the tub is described. Based on the criterion values [among others 6 - 8] an attempt to assess the technical condition of the electric power appliances diagnosed is made. The investigations and analyses carried out confirm that the measurement results of vibrations of the particular units have not revealed any damage to their cores or other defects of mechanical character.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 19-22
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Technical Condition of the Active Part of the High Power Transformer Based on Measurements and Analysis of Vibroacoustic Signals
Autorzy:
Borucki, S.
Cichoń, A.
Majchrzak, H.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/176397.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vibration
vibroacoustic method
core
power transformer
transformer diagnostics
Opis:
This article presents the results of research connected with the development and industrial use of vibroacoustic methods for the evaluation of the technical condition of the active part of transformers. The article presents the results of the analysis of vibrations generated by the high power transformer in which a defect was found on the basis of tests of oil carried out using the chromatography tests. In order to confirm the damage of the active part of this transformer, vibroacoustic measurements were performed in three states of its operation. The measurement using the classical vibroacoustic method included the registration of vibrations at the idle speed and during the load operation of the transformer. The original diagnostic method, so-called the modified vibroacoustic method, was also used during the measurement. The analysis of signals recorded using the classical vibroacoustic method was carried out in the frequency domain by indicating the amplitude of even harmonic vibrations. However, the analysis of signals measured during the commissioning of the transformer was conducted in the time-frequency domain using the short-time Fourier transform (STFT), continuous wavelet transform (CWT), and discrete wavelet transform (DWT). On the basis of the analysis of the results obtained it was stated that the increased level of vibrations of this transformer is a consequence of the loss of rigidity of the mechanical structure of its core.
Źródło:
Archives of Acoustics; 2017, 42, 2; 313-320
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka rdzenia transformatora elektroenergetycznego z wykorzystaniem zmodyfikowanej metody wibroakustycznej
Diagnosis of power transformer core using the modified vibroacoustic method
Autorzy:
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/153865.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
rdzeń
diagnostyka
analiza czasowo-częstotliwościowa
drgania
metoda wibroakustyczna
power transformer
core
diagnosis
time and frequency domain analysis
vibration
vibroacoustic method
Opis:
Genezę podjętych w artykule prac stanowi problem skutecznej oceny stanu technicznego konstrukcji mechanicznej rdzeni transformatorów elektroenergetycznych. W publikacji zaprezentowano wyniki wskazujące na możliwość opracowania nowej i bezinwazyjnej metody diagnostycznej rdzeni z wykorzystaniem zaproponowanej przez autora tzw. zmodyfikowanej metody wibroakustycznej (MVM). Zamieszczone w artykule oryginalne rezultaty badań uzyskano podczas prób laboratoryjnych z wykorzystaniem transformatora olejowego o mocy 200 kVA.
The problem of effective assessment of the technical condition of power transformer core mechanical structure originated the research work discussed in this paper. The investigation results show the possibility of developing a new and non-invasive diagnostic method for the transformer magnetic circuit. The method developed is based on time-frequency analysis of measured mechanical vibrations of the device monitored. The recording of vibrations is performed during the monitored transformer no-load operation. The paper characterises the power object under study (Fig. 1), the measuring system applied and discusses the new methodology for assessing the core technical condition using the modified vibroacoustic method (MVM). The original measurement results presented in the paper were obtained during switching on a 200 kVA transformer under laboratory conditions. The analysis of the signals measured was carried out for three operating conditions of the transformer under study: with the core pressed by a manufacturer; with the core with loose screws fixing the upper yoke (Fig. 2a) and with the core with loose screws fixing the upper and lower yokes (Fig. 2b). The research results (Figs. 3-5) obtained from this experiment show a potential possibility of developing a non-destructive and effective method for assessing the technical condition of the core mechanical structure of transformer units operating in the electric power system, especially the ones of a strategic character.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 331-334
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka stanu technicznego obwodu magnetycznego transformatorów energetycznych z wykorzystaniem zmodyfikowanej metody wibroakustycznej
Diagnostics of technical condition of power transformer magnetic circuit with use of a modified vibroacoustic method
Autorzy:
Borucki, S.
Cichoń, A.
Skubis, J.
Powiązania:
https://bibliotekanauki.pl/articles/153431.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
drgania mechaniczne
metoda wibroakustyczna
rdzeń
power transformer
mechanical vibrations
vibroacoustic method
core
Opis:
W publikacji scharakteryzowano zaproponowaną metodykę, tzw. zmodyfikowaną metodę wibroakustyczną, oraz przedstawiono rezultaty badań uzyskane na dwóch transformatorach, jednostce typu TR 16000/110 i TORb 25000/110. Ocenę efektywności opracowanej metodyki pomiarowo – diagnostycznej przeprowadzono poprzez korelację wyników analizy czasowo – częstotliwościowej zarejestrowanych wibracji z rezultatami badań chromatograficznych (DGA) oleju elektroizolacyjnego pobranego z kadzi monitorowanych urządzeń. Analizę zarejestrowanych drgań wykonano z wykorzystaniem przekształceń STFT, CWT i DWT.
The subject of the paper concerns evaluation of the technical condition of the power transformer magnetic circuit by measuring and analyzing vibrations recorded during switching on the transformer. This paper presents the results of technical verification of the noninvasive method used for diagnostics of transformer cores. The research on application of this method has been performed at the Institute of Power Engineering of the Opole University of Technology for several years. The paper characterizes the proposed methodology, the so-called modified vibroacoustic method, and presents the results obtained on two tested transformers, type TR 16000/110 and TORb 25000/110. Evaluation of the effectiveness of the developed methodology of diagnostic measurements was performed by correlation analysis of the time-frequency vibrations recorded with the results of chromatographic studies (DGA) of oil taken from the transformer tank. The recorded vibrations were analyzed using the transformation STFT (Short Time Fourier Transform), CWT (Continuous Wavelet Transform) and DWT (Discrete Wavelet Transform). On the basis of the results given in this paper as well as the currently conducted research work, it was found that there is a real possibility of using the developed method for noninvasive assessment of technical condition of mechanical construction of power transformer cores in operating conditions.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 102-105
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stanu technicznego transformatorów elektroenergetycznych z wykorzystaniem metody emisji akustycznej
Diagnostics of technical condition of power transformers with use of the Acoustic Emission Method
Autorzy:
Skubis, J.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153873.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
metoda emisji akustycznej
wyładowania niezupełne
izolacja papierowo-olejowa
diagnostyka
power transformer
acoustic emission method
partial discharges
paper-oil insulation
diagnostic
Opis:
Tematyka artykułu dotyczy wykonanych przez pracowników Politechniki Opolskiej badań związanych z detekcją, oceną intensywności i lokalizacją wyładowań niezupełnych metodą emisji akustycznej w trzech transformatorach elektroenergetycznych o mocach 125, 160 i 400 MVA. Rezultatem przeprowadzonych prac było sformułowanie rekomendacji technicznych dotyczących aktualnego stanu technicznego badanych jednostek. Analizę zarejestrowanych impulsów akustycznych przeprowadzono w dziedzinie czasu, częstotliwości i czasowo-częstotliwościowej.
An important part of a comprehensive evaluation of the technical condition of power transformers is detection, assessment of the intensity and location of partial discharges (PDs), that may occur in their paper-oil insulation systems. Modern monitoring techniques are increasingly using the acoustic emission (AE) method, which combines the features of the gas chromatography and electricity methods, to evaluate the electrical discharge. The paper presents investigations performed by a team of the Opole University of Technology dealing with the detection, evaluation, intensity and location of PDs by means of the AE method for three transformers of 125, 160 and 400 MVA power. The result of this work was formulation of technical recommendations for the current technical condition of units. The analysis of the recorded pulses EA was conducted in the time, frequency and time-frequency domain. The paper generally characterizes the possibility of the AE method, and the used measuring system (Fig. 1). There are given the technical parameters of the energy object under study (Figs. 2, 7 and 11). The results of detection, assessment of the intensity and location of electrical discharges in transformers diagnosed are shown in Figs. 3, 5, 6, 9, 10, 13, 14 and Tables 1-4.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 343-347
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time-Frequency Analysis of Mechanical Vibrations of the Dry Type Power Transformer Core
Autorzy:
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/1493019.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The paper presents research results referring to the development of a non-invasive method of assessment of the power transformer core technical condition based on the analysis of the mechanical vibrations registered. It characterizes the power object under study, the measuring system used and the developed methodology of assessment of the core pressing degree using the vibroacoustic method. The original results of the time-frequency analysis of the vibroacoustic signals presented in the paper were obtained during switching on a real 800 kVA dry type power transformer in laboratory conditions. The analysis of the signals registered was carried out for three states of its operation: the core pressed by the manufacturer, the core with loose screws fixing the upper yoke and the core with separated upper yoke beams.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 571-574
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczny przykład skutecznej detekcji i lokalizacji wyładowań niezupełnych metodą emisji akustycznej w transformatorze elektroenergetycznym
Practical example of effective detection and location of partial discharges by the acoustic emission method in an electric power transformer
Autorzy:
Skubis, J.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/155763.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
metoda emisji akustycznej
diagnostyka
transformator elektroenergetyczny
partial discharges
acoustic emission method
diagnostics
power transformer
Opis:
W artykule przedstawiono przykład diagnostyki transformatora elektro-energetycznego pod kątem oceny stanu technicznego papierowo - olejowego układu izolacyjnego zagrożonego występowaniem wyładowań niezupełnych (WNZ). Badania przeprowadzono podczas normalnej pracy jednostki transformatorowej, rejestrując w 36 punktach na powierzchni kadzi sygnały emisji akustycznej (EA) pochodzącej od zjawisk fizycznych występujących wewnątrz transformatora. Zarejestrowane sygnały poddano analizie w dziedzinie czasowej, częstotliwościowej i czasowo - częstotliwościowej. Wynikiem badań była detekcja i lokalizacja miejsca występowania wyładowań elektrycznych oraz wskazanie prawdopodobnej przyczyny i miejsca ich powstawania.
Three measurement methods: gas chromatography method (DGA), electrical method and AE method are used in the assessment of the technical condition of paper-oil insulation of high-power transformers exposed to the occurrence of partial discharges (PDs). The acoustic method of PD detection is used as a supplementary one to the two others, mainly the gas chromatography method which does not make it possible to locate the place of the insulation system defect appearance. The basic advantage of the AE method, compared with the electrical one, is the possibility of its application during regular operation of power appliances [2, 3]. The paper presents the measurement results of the AE signals accompanying regular operation of a power transformer of 270 MVA. In order to assess the intensity of the AE signals measured on the object under study, coming from physical phenomena taking place inside a tub, three analyses were performed: in the time, frequency and time-frequency domains. Registration of the AE signals, the distributions of which is shown in Fig. 2, was carried out at 36 measurement points. An exemplary waveform of the AE signals registered is shown in Fig. 3, while the results of the analysis in the time domain are listed in Tables 1 and 2. In order to assess the waveforms registered more accurately, the analysis in the frequency domain was carried out and amplitude spectra were determined, an example of which is presented in Fig. 4. The time-frequency analysis was performed by using a short-time Fourier transform (STFT) determining two-dimensional spectrograms of the power density spectrum (Fig. 5). The assessment of the technical condition of the transformer under study made it possible to detect and locate areas in which PDs occurred. Damage of magnetic screens is a probable cause of their occurrence.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 30-33
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie klasyfikatora neuronowego w systemie eksperckim oceny stanu układów izolacyjnych transformatorów elektroenergetycznych
The Application of a Neural Classifier in an Expert System for the Evaluation of the Condition of Power Transformer Insulation System
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153524.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
sieci neuronowe
system ekspercki
układ izolacyjny
transformator elektroenergetyczny
partial discharge
artificial neural network
expert's system
paper-oil insulation
power transformer
Opis:
Tematyka artykułu dotyczy oceny możliwości wykorzystania jednokierunkowej sieci neuronowej w systemie eksperckim diagnostyki stanu układów izolacyjnych transformatorów elektroenergetycznych. W artykule przedstawiono teoretyczne i praktyczne możliwości budowy systemu ekspertowego, bazującego na metodzie emisji akustycznej, wspomagającego diagnostykę układów izolacyjnych transformatorów dużej mocy. Zamieszczone w pracy wyniki przedstawiają skuteczność rozpoznawania badanych form WNZ (defektów izolacji), uzyskaną przy zastosowaniu klasyfikatora neuronowego, jak również ocenę możliwości jego zastosowania jako mechanizmu wnioskującego komputerowego systemu diagnostycznego.
The subject matter of the paper refers to the evaluation of the application possibilities of a single-direction neural network in the expert system of the diagnostics of the insulation system condition. The paper presents theoretical and practical possibilities of building an expert system based on the acoustic emission method, assisting the diagnostics of insulation systems of high power transformers. The results presented in this paper show the recognition effectiveness of the PD forms under study (insulation defects), obtained by using a neural classifier as well as the evaluation of its application possibilities as an inferring mechanism of a computer diagnostic system.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 10, 10; 29-32
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repeatability Estimation for Vibration Measurement Results of Power Transformer Core
Autorzy:
Borucki, S.
Cichon, A.
Skubis, J.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/1198972.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The subject matter of this paper refers to the diagnostics of a transformer core, based on measurements and analysis of vibroacoustic signals registered during their normal operation. The paper presents results of the research aimed to evaluate the repeatability of vibration measurements for power transformer core. Recording of vibroacoustic signals was performed under laboratory conditions on dry-insulated transformers. The study concerned evaluation of changes in vibroacoustic indicators of the transformer core during operation with a turned and loosened core. Conclusions from the measurement results were drawn on the basis of the parametric test of significance derived from the variance analysis for many means of single classification basing on the Fisher-Snedecor F-distribution.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1299-1302
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of 3D Modeling in the Diagnosis of Power Capacitors with Acoustic Emission Method
Autorzy:
Boczar, T.
Błachowicz, A.
Borucki, S.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/1417933.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.Le
07.05.Tp
Opis:
The article presents the issue modelling the partial discharge phenomenon in engineering and scientific environments using hardware-based computer cluster. The authors present the results of research work on the phenomenon of acoustic emission from partial discharge occurring in power capacitors for power factor correction. The work includes the issues presentation and explanation of solutions enabling to create 3D spatial model of power capacitor. The authors proposed a simplified model of an acoustic test object aimed at improving the process of calculating the results.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 796-799
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Acoustic Signals Interfering Diagnostic Measurements of Electric Power Transformer Tap Changers
Autorzy:
Boczar, T.
Cichoń, A.
Borucki, S.
Szczyrba, T.
Powiązania:
https://bibliotekanauki.pl/articles/1399334.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.58.-e
43.60.-c
43.60.Bf
Opis:
Subject matter of this paper applies to improvement of acoustic emission method used in the diagnosis of on load tap changers of high power transformers. During measurement of acoustic emission signals generated by damages or defects, which can appear in insulation system and in the power transformer tap changers, various forms of noise signals may occur. Interferences occurring during measurements under laboratory and under industrial conditions can be generated either by sources placed inside the studied electric power device or they can be emitted in their immediate vicinity. Sources of interfering signals are physical phenomena of a mechanical, electrical or acoustical nature. Interferences appearing during measurement of acoustic emission pulses generated by electrical discharges and other types of defects that overlap the measured waveforms may result in their distortion. As part of the research conducted, the results of which are presented in this paper, following was subjected under consideration: measurements of acoustic noise signals generated by partial surface discharges occurring on support and bushing insulators were performed.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 387-390
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Descriptors of Acoustic Emission Signals Generated by Partial Discharges under Laboratory Conditions and in On-Site Electrical Power Transformer
Autorzy:
Kunicki, M.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176881.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
An acoustic emission method (AE) is widespread and often applied for partial discharge (PD) diagnostics, mainly due to its ease of application as well as noninvasiveness and relatively high sensitivity. This paper presents comparative analysis of AE signals measurement results archived under laboratory conditions as well as on-site actual AE signals generated by inside PDs in electrical power transformer during its normal service. Three different PD model sources are applied for laboratory research: point to point, multipoint to plate and surface type. A typical measuring set up commonly used for on-site transformer PD diagnostics is provided for the laboratory tasks: piezoelectric joint transducer, preamplifier, amplifier and measuring PC interface. During the on-site research there are three measuring tracks applied simultaneously. Time domain, time-frequency domain and statistical tools are used for registered AE signals analysis. A number of descriptors are proposed as a result of the analysis. In the paper, attempt of AE signals descriptors, archived under laboratory condition application possibilities for on-site PD diagnostics of power transformers during normal service is made.
Źródło:
Archives of Acoustics; 2016, 41, 2; 265-276
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Wavelet Analysis of the Vibroacoustic Signal Measurement in a Transient State Operation of Power Transformer
Autorzy:
Borucki, S.
Cichon, A.
Boczar, T.
Zmarzly, D.
Powiązania:
https://bibliotekanauki.pl/articles/1417934.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The article presents the results of attempts made to develop a non-invasive diagnostic method of a technical state of a transformer's core based on an analysis of mechanical vibrations registered during the start-up of the transformer analyzed. The paper presents a characteristic of the transformer under study, the measuring systems applied and the method developed for assessing the degree of the core loosening. The original results presented in the paper have been obtained under laboratory conditions during tests conducted on an oil transformer of 200 kVA. The analysis of recorded virboacoustic signals was performed by means of discrete wavelet transform for three different operating cases: the transformer with no core defect, the transformer with loose screws of the magnetic circuit of the upper yoke, and the transformer with completely loosen screws of the beam of the upper yoke and the lower core. The signals have been recorded on two perpendicular measuring axes: 0X and 0Y and their measured values were subject to the wavelet analysis.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 800-803
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies