Tytuł:
Technical Possibilities of Reducing the Sound Pressure Level Emitted into the Environment by a Power Transformer
Autorzy:
Borucki, S.
Boczar, T.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177473.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
corrected sound pressure level
noise
modernization
Opis:
The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.
Źródło:
Archives of Acoustics; 2011, 36, 1; 49-56
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Acoustic Emission Signals Generated in On Load Tap Changer
Autorzy:
Cichoń, A.
Borucki, S.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/1199209.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The paper deals with mathematical modeling of acoustic emission signals which are generated in on load tap changers. In power engineering area acoustic emission method is commonly used for diagnosis purposes. Authors in their research works apply it for detection of defects occurring in on load tap changers, which are important elements of power transformers. The acoustic emission method is based on measurements performed by use of wideband piezoelectric transducers that are mounted on transformer tank surface. The registered signal is then analyzed in the time, frequency, and time-frequency domains or is evaluated with computer expert systems for diagnosis purposes. Depending on indicators device technical condition can be determined. The contribution given by the authors in this paper is proposal of a mathematical model, which describes envelope of the measured acoustic emission signal.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1396-1399
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selecting Sensor for On Load Tap Changer Contacts Degree of Wear Diagnostics
Autorzy:
Cichoń, A.
Borucki, S.
Berger, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399337.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
Results of scientific research works considering selection of measuring transducer applied for registration of acoustic emission signals generated by on load tap changers are presented in the paper. During the coupling process acoustic emission signals are generated by: the mechanical setup of tap changer, contacts operation, and other phenomena. For most on load tap changers types, the working medium is insulation oil in which the acoustic wave being formed propagates to the steal tank. There exists a possibility to register acoustic emission signals with a piezoelectric transducer attached to the outer tank surface or with a hydrophone immersed in the oil. Acoustic emission signal obtained in such manner contains information which describes operation of the power tap changer and the selector. A comparative analysis of acoustic emission signals generated by on load tap changers working under laboratory conditions, with applied measuring transducers with different transmittances, is presented in the paper. The comparative analysis was performed in order to determine their suitability for on load tap changers technical condition diagnosis. Based on the results achieved, one transducer which allows the registration of acoustic events generated during on load tap changers operation was selected.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 395-398
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Descriptors of Acoustic Emission Signals Generated by Partial Discharges under Laboratory Conditions and in On-Site Electrical Power Transformer
Autorzy:
Kunicki, M.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176881.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
An acoustic emission method (AE) is widespread and often applied for partial discharge (PD) diagnostics, mainly due to its ease of application as well as noninvasiveness and relatively high sensitivity. This paper presents comparative analysis of AE signals measurement results archived under laboratory conditions as well as on-site actual AE signals generated by inside PDs in electrical power transformer during its normal service. Three different PD model sources are applied for laboratory research: point to point, multipoint to plate and surface type. A typical measuring set up commonly used for on-site transformer PD diagnostics is provided for the laboratory tasks: piezoelectric joint transducer, preamplifier, amplifier and measuring PC interface. During the on-site research there are three measuring tracks applied simultaneously. Time domain, time-frequency domain and statistical tools are used for registered AE signals analysis. A number of descriptors are proposed as a result of the analysis. In the paper, attempt of AE signals descriptors, archived under laboratory condition application possibilities for on-site PD diagnostics of power transformers during normal service is made.
Źródło:
Archives of Acoustics; 2016, 41, 2; 265-276
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of the Core Mechanical Construction Based on Vibroacoustic Measurements and Distribution of Temperature Field in Transformer Magnetic Circuit
Autorzy:
Borucki, S.
Cichon, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/1401874.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
Subject matter of this article concerns the results of research works on the development and use of the vibroacoustic method to evaluate technical state of transformer cores. The article presents obtained measurement results of transformer mechanical vibration for two cases of its operation: with twisted and loosened core. In order to demonstrate negative effects of operating a transformer with a loosened core, this publication presents thermographic images showing temperature distribution on its magnetic core. The article characterises the examined transformer, employed measurement system and methodology of the completed experiment. The vibroacoustic and thermographic measurements were carried out during idle work of the transformer. Core vibration was registered for three measurement axes: 0X, 0Y and 0Z. Completed tests have proven that loosened screws pressing the core cause evident increase in the value of magnetic core vibration acceleration. At the same time, the temperature rises by more than 25%.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 306-309
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie klasyfikatora neuronowego w systemie eksperckim oceny stanu układów izolacyjnych transformatorów elektroenergetycznych
The Application of a Neural Classifier in an Expert System for the Evaluation of the Condition of Power Transformer Insulation System
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153524.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
sieci neuronowe
system ekspercki
układ izolacyjny
transformator elektroenergetyczny
partial discharge
artificial neural network
expert's system
paper-oil insulation
power transformer
Opis:
Tematyka artykułu dotyczy oceny możliwości wykorzystania jednokierunkowej sieci neuronowej w systemie eksperckim diagnostyki stanu układów izolacyjnych transformatorów elektroenergetycznych. W artykule przedstawiono teoretyczne i praktyczne możliwości budowy systemu ekspertowego, bazującego na metodzie emisji akustycznej, wspomagającego diagnostykę układów izolacyjnych transformatorów dużej mocy. Zamieszczone w pracy wyniki przedstawiają skuteczność rozpoznawania badanych form WNZ (defektów izolacji), uzyskaną przy zastosowaniu klasyfikatora neuronowego, jak również ocenę możliwości jego zastosowania jako mechanizmu wnioskującego komputerowego systemu diagnostycznego.
The subject matter of the paper refers to the evaluation of the application possibilities of a single-direction neural network in the expert system of the diagnostics of the insulation system condition. The paper presents theoretical and practical possibilities of building an expert system based on the acoustic emission method, assisting the diagnostics of insulation systems of high power transformers. The results presented in this paper show the recognition effectiveness of the PD forms under study (insulation defects), obtained by using a neural classifier as well as the evaluation of its application possibilities as an inferring mechanism of a computer diagnostic system.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 10, 10; 29-32
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stanu technicznego transformatorów elektroenergetycznych z wykorzystaniem metody emisji akustycznej
Diagnostics of technical condition of power transformers with use of the Acoustic Emission Method
Autorzy:
Skubis, J.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153873.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
metoda emisji akustycznej
wyładowania niezupełne
izolacja papierowo-olejowa
diagnostyka
power transformer
acoustic emission method
partial discharges
paper-oil insulation
diagnostic
Opis:
Tematyka artykułu dotyczy wykonanych przez pracowników Politechniki Opolskiej badań związanych z detekcją, oceną intensywności i lokalizacją wyładowań niezupełnych metodą emisji akustycznej w trzech transformatorach elektroenergetycznych o mocach 125, 160 i 400 MVA. Rezultatem przeprowadzonych prac było sformułowanie rekomendacji technicznych dotyczących aktualnego stanu technicznego badanych jednostek. Analizę zarejestrowanych impulsów akustycznych przeprowadzono w dziedzinie czasu, częstotliwości i czasowo-częstotliwościowej.
An important part of a comprehensive evaluation of the technical condition of power transformers is detection, assessment of the intensity and location of partial discharges (PDs), that may occur in their paper-oil insulation systems. Modern monitoring techniques are increasingly using the acoustic emission (AE) method, which combines the features of the gas chromatography and electricity methods, to evaluate the electrical discharge. The paper presents investigations performed by a team of the Opole University of Technology dealing with the detection, evaluation, intensity and location of PDs by means of the AE method for three transformers of 125, 160 and 400 MVA power. The result of this work was formulation of technical recommendations for the current technical condition of units. The analysis of the recorded pulses EA was conducted in the time, frequency and time-frequency domain. The paper generally characterizes the possibility of the AE method, and the used measuring system (Fig. 1). There are given the technical parameters of the energy object under study (Figs. 2, 7 and 11). The results of detection, assessment of the intensity and location of electrical discharges in transformers diagnosed are shown in Figs. 3, 5, 6, 9, 10, 13, 14 and Tables 1-4.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 343-347
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości wykorzystania sygnałów emisji akustycznej do detekcji wyładowań niezupełnych w izolatorach przepustowych
Application possibility estimation of acoustic emission signals for detection of partial discharges in bushing isolators
Autorzy:
Cichoń, A.
Borucki, S.
Subocz, J.
Powiązania:
https://bibliotekanauki.pl/articles/153875.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolatory przepustowe
wyładowania niezupełne
metoda emisji akustycznej
diagnostyka elektroenergetyczna
bushing isolator
partial discharges
acoustic emission method
electric power diagnosis
Opis:
W artykule przedstawiono wyniki prac naukowo - badawczych związanych z detekcją wyładowań niezupełnych (WNZ) w izolatorach przepustowych z wykorzystaniem metody emisji akustycznej (EA). Badania przeprowadzono w warunkach laboratoryjnych wykorzystując model izolatora typu GSKTFK, w którym osłonę porcelanową zastąpiono obudową wykonaną z tworzywa sztucznego. Pomiary wykonywano w układach modelujących różne rodzaje uszkodzeń. Sygnały EA rejestrowano za pomocą piezoelektrycznego przetwornika stykowego przymocowanego do zewnętrznej części osłony izolatora. Analizę zarejestrowanych sygnałów przeprowadzono w dziedzinie czasowo - częstotliwościowej z wykorzystaniem krótkoczasowej transformaty Fouriera (STFT). Efektem przeprowadzonych prac było określenie możliwości wykorzystania metody EA do detekcji WNZ powstających na skutek różnych rodzajów defektów w izolacji papierowo - olejowej.
Reliable operation of an electric power system is connected with the necessity of maintenance of its particular elements for theirs good technical state. Important part of the electric power network is the high power transformer, which inherent elements are bushing isolators. Effective detection of PDs in inner part of the paper-oil isolation is one of the main conditions which assure safety operation of bushing isolators. Limited possibility for switching off the electric power devices is a reason for looking for new diagnostic methods enabling on-line measurements execution. Measurements results of AE signals generated in a bushing isolator: with defective inner paper-oil isolation, with presence of air blebs freely moving inside the isolation system, with forced motion of air blebs and with entered natural aging products of cellulose between the particular layers of the insulating system are presented in the paper. Results achieved in the scope of works performed confirmed the application possibility of AE method for technical state diagnosis of paper-oil insulation of bushing isolators in terms of PD appearance. During measurements of AE signals two kinds of PDs have been observed: electrical discharges in the inner part of paper-oil isolation and inside the air blebs. Time-frequency analysis has enabled to assign characteristic frequency bands to the particular PD types. This has created a basis for further works aiming development of research methodic enabling for AE signals measurement on bushing isolators under normal operation condition.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 348-351
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the Acoustic Emission Method for Diagnosis of On-Load Tap Changer
Autorzy:
Majchrzak, H.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176624.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
This paper provides an example of the application of the acoustic emission (AE) method for the diagnosis of technical conditions of a three-phase on-load tap-changer (OLTC) GIII type. The measurements were performed for an amount of 10 items of OLTCs, installed in power transformers with a capacity of 250 MVA. The study was conducted in two different OLTC operating conditions during the tapping process: under load and free running conditions. The analysis of the measurement results was made in both time domain and time-frequency domain. The description of the AE signals generated by the OLTC in the time domain was performed using the analysis of waveforms and determined characteristic times. Within the time-frequency domain the measured signals were described by short-time Fourier transform spectrograms.
Źródło:
Archives of Acoustics; 2017, 42, 1; 29-35
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Interference Signals Generated by Vibroacoustic Vibrations of Transformer Cores
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/1199078.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
79.60.Bm
42.79.Pw
52.80.Hc
Opis:
The article deals with the subject matter referring to the interference that may accompany measurements of vibroacoustic signals, generated by electric power transformers, taken by using the acoustic emission method under industrial conditions. Paper concerns measurement and analysis of internal, acoustic type disturbances, including the magnetostrictive vibrations of plate sets within the transformer core, caused by changes in the magnetic flux. Paper presents measurement results of acoustic interfering signals and results of analyses made in the frequency and time-frequency domains. Power spectral density, MUSIC pseudospectra, two- and three-dimensional short time Fourier transform spectrograms, continuous wavelet transform scalograms, discrete wavelet transform, and quantities of energy transferred are included in the paper.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1355-1359
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza wyników badań w zakresie oceny stopnia zużycia styków PPZ metodą akustyczną i oscylograficzną
Comparison analysis of research results on determining level of OLTC contact deterioration using acoustic and oscillographic methods of diagnostics
Autorzy:
Cichoń, A.
Bergber, P.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/152504.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
podobciążeniowe przełączniki zaczepów (PPZ)
diagnostyka transformatorów elektroenergetycznych
metoda emisji akustycznej
on load tap changer (OLTC)
electric power transformer diagnostics
acoustic emission method
Opis:
W artykule przedstawiono wyniki prac naukowo – badawczych związanych z diagnostyką podobciążeniowych przełączników zaczepów (PPZ). Badania wykonano w warunkach laboratoryjnych z wykorzystaniem modelu fizycznego PPZ typu VEL 110, umieszczonego w kadzi wypełnionej olejem izolacyjnym. Sygnały emisji akustycznej rejestrowano szerokopasmowym przetwornikiem piezoelektrycznym przymocowanym do zewnętrznej części kadzi. Zarejestrowane sygnały poddano analizie w dziedzinie czasowej. Wyniki pomiarów metodą oscylograficzną przedstawiono w postaci przebiegów prądowych i wyznaczając wartości czasów własnych. Na podstawie uzyskanych wyników przeprowadzono analizę porównawczą wyników uzyskanych za pomocą obu metod pomiarowych.
This paper presents results of scientific research on diagnostic methods for on load tap changers (OLTC). Measurements were made in laboratory conditions with use of a physical model of the VEL 110 OLTC placed in a tank filled with insulating oil. Acoustic emission signals were recorded with use of a R15α wide band piezoelectric transducer which was fixed to the tank of the model. These signals were analyzed in the time domain, which resulted in calculation of the signal envelope and its characteristic times. The results of the oscillographic measurements are presented in the form of current diagrams and the calculated OLTC characteristic times. Basing on the obtained results of the oscillographic and acoustic measurements, a comparison analysis of both diagnostic methods was performed. The research data presented in this paper proves that detection of OLTC contact deterioration is possible by using both oscillographic and acoustic methods of diagnostics.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 152-155
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
Autorzy:
Cichoń, A.
Borucki, S.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177044.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
on-load tap changers
acoustic emission method
Opis:
On-load tap changers (OLTC) are some of the main transformer elements that make voltage adjustment in a power network possible. Their failures often cause shutdowns of distribution transformers. The paper presents research work aimed at the assessment of the technical condition of OLTCs by the acoustic emission method (EA). This method makes the OLTC diagnosis possible without the need of disconnecting the transformer from the system. The measurements were taken in laboratory conditions. The influence on the operation non-concurrence of the power tap changer contacts on the AE registered signals has been investigated. The signals registered were subjected to analyses in the time and time-frequency domains. The result analysis in the time domain was carried out using the Hilbert transform and calculating characteristic times for the particular runs. A short-time Fourier transform was used for the assessment of results in the time-frequency do- main.
Źródło:
Archives of Acoustics; 2011, 36, 4; 823-830
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów energetycznych z wykorzystaniem metody wibroakustycznej
Diagnostics of Power Transformers Using the Vibroacoustic Method
Autorzy:
Borucki, S.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155761.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator energetyczny
drgania
rdzeń
metoda wibroakustyczna
diagnostyka
power transformer
vibration
core
vibroacoustic method
diagnostic
Opis:
Tematyka artykułu dotyczy diagnostyki rdzeni transformatorów elektro-energetycznych dużej mocy z wykorzystaniem pomiarów drgań wibroaku-stycznych. W artykule, na podstawie analizy drgań mechanicznych kadzi, dokonano oceny stanu technicznego czterech transformatorów blokowych typu TFBb 240000/400. Scharakteryzowano układ pomiarowy, który został wykorzystany podczas rejestracji sygnałów pochodzących od przenoszonych przez kadź drgań rdzenia poszczególnych jednostek. W oparciu o przyjęte w artykule wartości kryterialne podjęto próbę oceny stanu technicznego diagnozowanych urządzeń elektroenergetycznych.
During its operation a power transformer is subjected to the influence of numerous unfavourable factors which shorten its operation time and can cause unexpected disastrous failures. As far as the active part of a transformer is considered, magnetostrictic vibrations and cellulose depolymerization are the most harmful factors causing the loss of mechanical strength. Their influence results in the gradual loosening of the pressing and clamping of the core and transformer windings, which leads to the weakening of the active part mechanical construction (Fig. 1). In the electric power sector there are a few methods for detection of damages in power transformers. One of them is the vibroacoustic method which consists in measurement and analysis of vibrations of the object under study. Its application to high-power transformer diagnostics enables, first of all, assessing the technical condition of the core. Additionally, combining this method with other diagnostic methods can provide information not only on the core technical condition but also on the solid insulation properties of the device being tested [5 - 6]. In the paper the technical assessment of the condition of four unit transformers of type TFBb 240000/400 is performed basing on the analysis of mechanical vibrations of the tub. The basic technical parameters of the transformers are listed in Table 1. The measuring system used for recording the signals coming from the core vibrations of the particular units and transferred by the tub is described. Based on the criterion values [among others 6 - 8] an attempt to assess the technical condition of the electric power appliances diagnosed is made. The investigations and analyses carried out confirm that the measurement results of vibrations of the particular units have not revealed any damage to their cores or other defects of mechanical character.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 19-22
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka stanu technicznego obwodu magnetycznego transformatorów energetycznych z wykorzystaniem zmodyfikowanej metody wibroakustycznej
Diagnostics of technical condition of power transformer magnetic circuit with use of a modified vibroacoustic method
Autorzy:
Borucki, S.
Cichoń, A.
Skubis, J.
Powiązania:
https://bibliotekanauki.pl/articles/153431.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
drgania mechaniczne
metoda wibroakustyczna
rdzeń
power transformer
mechanical vibrations
vibroacoustic method
core
Opis:
W publikacji scharakteryzowano zaproponowaną metodykę, tzw. zmodyfikowaną metodę wibroakustyczną, oraz przedstawiono rezultaty badań uzyskane na dwóch transformatorach, jednostce typu TR 16000/110 i TORb 25000/110. Ocenę efektywności opracowanej metodyki pomiarowo – diagnostycznej przeprowadzono poprzez korelację wyników analizy czasowo – częstotliwościowej zarejestrowanych wibracji z rezultatami badań chromatograficznych (DGA) oleju elektroizolacyjnego pobranego z kadzi monitorowanych urządzeń. Analizę zarejestrowanych drgań wykonano z wykorzystaniem przekształceń STFT, CWT i DWT.
The subject of the paper concerns evaluation of the technical condition of the power transformer magnetic circuit by measuring and analyzing vibrations recorded during switching on the transformer. This paper presents the results of technical verification of the noninvasive method used for diagnostics of transformer cores. The research on application of this method has been performed at the Institute of Power Engineering of the Opole University of Technology for several years. The paper characterizes the proposed methodology, the so-called modified vibroacoustic method, and presents the results obtained on two tested transformers, type TR 16000/110 and TORb 25000/110. Evaluation of the effectiveness of the developed methodology of diagnostic measurements was performed by correlation analysis of the time-frequency vibrations recorded with the results of chromatographic studies (DGA) of oil taken from the transformer tank. The recorded vibrations were analyzed using the transformation STFT (Short Time Fourier Transform), CWT (Continuous Wavelet Transform) and DWT (Discrete Wavelet Transform). On the basis of the results given in this paper as well as the currently conducted research work, it was found that there is a real possibility of using the developed method for noninvasive assessment of technical condition of mechanical construction of power transformer cores in operating conditions.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 102-105
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczny przykład skutecznej detekcji i lokalizacji wyładowań niezupełnych metodą emisji akustycznej w transformatorze elektroenergetycznym
Practical example of effective detection and location of partial discharges by the acoustic emission method in an electric power transformer
Autorzy:
Skubis, J.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/155763.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
metoda emisji akustycznej
diagnostyka
transformator elektroenergetyczny
partial discharges
acoustic emission method
diagnostics
power transformer
Opis:
W artykule przedstawiono przykład diagnostyki transformatora elektro-energetycznego pod kątem oceny stanu technicznego papierowo - olejowego układu izolacyjnego zagrożonego występowaniem wyładowań niezupełnych (WNZ). Badania przeprowadzono podczas normalnej pracy jednostki transformatorowej, rejestrując w 36 punktach na powierzchni kadzi sygnały emisji akustycznej (EA) pochodzącej od zjawisk fizycznych występujących wewnątrz transformatora. Zarejestrowane sygnały poddano analizie w dziedzinie czasowej, częstotliwościowej i czasowo - częstotliwościowej. Wynikiem badań była detekcja i lokalizacja miejsca występowania wyładowań elektrycznych oraz wskazanie prawdopodobnej przyczyny i miejsca ich powstawania.
Three measurement methods: gas chromatography method (DGA), electrical method and AE method are used in the assessment of the technical condition of paper-oil insulation of high-power transformers exposed to the occurrence of partial discharges (PDs). The acoustic method of PD detection is used as a supplementary one to the two others, mainly the gas chromatography method which does not make it possible to locate the place of the insulation system defect appearance. The basic advantage of the AE method, compared with the electrical one, is the possibility of its application during regular operation of power appliances [2, 3]. The paper presents the measurement results of the AE signals accompanying regular operation of a power transformer of 270 MVA. In order to assess the intensity of the AE signals measured on the object under study, coming from physical phenomena taking place inside a tub, three analyses were performed: in the time, frequency and time-frequency domains. Registration of the AE signals, the distributions of which is shown in Fig. 2, was carried out at 36 measurement points. An exemplary waveform of the AE signals registered is shown in Fig. 3, while the results of the analysis in the time domain are listed in Tables 1 and 2. In order to assess the waveforms registered more accurately, the analysis in the frequency domain was carried out and amplitude spectra were determined, an example of which is presented in Fig. 4. The time-frequency analysis was performed by using a short-time Fourier transform (STFT) determining two-dimensional spectrograms of the power density spectrum (Fig. 5). The assessment of the technical condition of the transformer under study made it possible to detect and locate areas in which PDs occurred. Damage of magnetic screens is a probable cause of their occurrence.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 30-33
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies