Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power transformer" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Technical Possibilities of Reducing the Sound Pressure Level Emitted into the Environment by a Power Transformer
Autorzy:
Borucki, S.
Boczar, T.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177473.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
corrected sound pressure level
noise
modernization
Opis:
The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.
Źródło:
Archives of Acoustics; 2011, 36, 1; 49-56
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
Autorzy:
Cichoń, A.
Borucki, S.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177044.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
on-load tap changers
acoustic emission method
Opis:
On-load tap changers (OLTC) are some of the main transformer elements that make voltage adjustment in a power network possible. Their failures often cause shutdowns of distribution transformers. The paper presents research work aimed at the assessment of the technical condition of OLTCs by the acoustic emission method (EA). This method makes the OLTC diagnosis possible without the need of disconnecting the transformer from the system. The measurements were taken in laboratory conditions. The influence on the operation non-concurrence of the power tap changer contacts on the AE registered signals has been investigated. The signals registered were subjected to analyses in the time and time-frequency domains. The result analysis in the time domain was carried out using the Hilbert transform and calculating characteristic times for the particular runs. A short-time Fourier transform was used for the assessment of results in the time-frequency do- main.
Źródło:
Archives of Acoustics; 2011, 36, 4; 823-830
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów energetycznych z wykorzystaniem metody wibroakustycznej
Diagnostics of Power Transformers Using the Vibroacoustic Method
Autorzy:
Borucki, S.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155761.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator energetyczny
drgania
rdzeń
metoda wibroakustyczna
diagnostyka
power transformer
vibration
core
vibroacoustic method
diagnostic
Opis:
Tematyka artykułu dotyczy diagnostyki rdzeni transformatorów elektro-energetycznych dużej mocy z wykorzystaniem pomiarów drgań wibroaku-stycznych. W artykule, na podstawie analizy drgań mechanicznych kadzi, dokonano oceny stanu technicznego czterech transformatorów blokowych typu TFBb 240000/400. Scharakteryzowano układ pomiarowy, który został wykorzystany podczas rejestracji sygnałów pochodzących od przenoszonych przez kadź drgań rdzenia poszczególnych jednostek. W oparciu o przyjęte w artykule wartości kryterialne podjęto próbę oceny stanu technicznego diagnozowanych urządzeń elektroenergetycznych.
During its operation a power transformer is subjected to the influence of numerous unfavourable factors which shorten its operation time and can cause unexpected disastrous failures. As far as the active part of a transformer is considered, magnetostrictic vibrations and cellulose depolymerization are the most harmful factors causing the loss of mechanical strength. Their influence results in the gradual loosening of the pressing and clamping of the core and transformer windings, which leads to the weakening of the active part mechanical construction (Fig. 1). In the electric power sector there are a few methods for detection of damages in power transformers. One of them is the vibroacoustic method which consists in measurement and analysis of vibrations of the object under study. Its application to high-power transformer diagnostics enables, first of all, assessing the technical condition of the core. Additionally, combining this method with other diagnostic methods can provide information not only on the core technical condition but also on the solid insulation properties of the device being tested [5 - 6]. In the paper the technical assessment of the condition of four unit transformers of type TFBb 240000/400 is performed basing on the analysis of mechanical vibrations of the tub. The basic technical parameters of the transformers are listed in Table 1. The measuring system used for recording the signals coming from the core vibrations of the particular units and transferred by the tub is described. Based on the criterion values [among others 6 - 8] an attempt to assess the technical condition of the electric power appliances diagnosed is made. The investigations and analyses carried out confirm that the measurement results of vibrations of the particular units have not revealed any damage to their cores or other defects of mechanical character.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 19-22
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie klasyfikatora neuronowego w systemie eksperckim oceny stanu układów izolacyjnych transformatorów elektroenergetycznych
The Application of a Neural Classifier in an Expert System for the Evaluation of the Condition of Power Transformer Insulation System
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153524.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
sieci neuronowe
system ekspercki
układ izolacyjny
transformator elektroenergetyczny
partial discharge
artificial neural network
expert's system
paper-oil insulation
power transformer
Opis:
Tematyka artykułu dotyczy oceny możliwości wykorzystania jednokierunkowej sieci neuronowej w systemie eksperckim diagnostyki stanu układów izolacyjnych transformatorów elektroenergetycznych. W artykule przedstawiono teoretyczne i praktyczne możliwości budowy systemu ekspertowego, bazującego na metodzie emisji akustycznej, wspomagającego diagnostykę układów izolacyjnych transformatorów dużej mocy. Zamieszczone w pracy wyniki przedstawiają skuteczność rozpoznawania badanych form WNZ (defektów izolacji), uzyskaną przy zastosowaniu klasyfikatora neuronowego, jak również ocenę możliwości jego zastosowania jako mechanizmu wnioskującego komputerowego systemu diagnostycznego.
The subject matter of the paper refers to the evaluation of the application possibilities of a single-direction neural network in the expert system of the diagnostics of the insulation system condition. The paper presents theoretical and practical possibilities of building an expert system based on the acoustic emission method, assisting the diagnostics of insulation systems of high power transformers. The results presented in this paper show the recognition effectiveness of the PD forms under study (insulation defects), obtained by using a neural classifier as well as the evaluation of its application possibilities as an inferring mechanism of a computer diagnostic system.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 10, 10; 29-32
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies