Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wind turbines" wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
Studies on Infrasound Noise Emitted by Wind Turbines of Large Power
Autorzy:
Boczar, T.
Malec, T.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/1418027.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.28.Dm
07.10.-h
46.40.-f
43.50.-x
43.50.+y
Opis:
The subject area of this article applies to study of infrasound signals generated by the work of modern wind turbines. Infrasound noise measurements were conducted in accordance with assumptions of the EN 61400-11 standard. The object of study was a newly commissioned wind farm with a total electrical power equal to 30 MW. The considered power station consisted of 15 new wind turbines, each with a capacity of 2 MW. Scope of the analysis performed included designation of time runs, depicting temporal changes, and designation of frequency spectra of the recorded infrasound signals. Evaluation of the impact of changes in wind speed was made. Moreover, the scope of analysis, performed in this field, concerned assessment of the impact on the obtained results values of meteorological parameters related to the applied measurement system. Values obtained from measurements were related to and compared with the limits specified in standards and regulations existing in this field.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 850-853
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Vibro-Acoustic Signals Generated during Operation of Micro Wind Turbines
Autorzy:
Wotzka, D.
Boczar, T.
Malec, T.
Pierzga, R.
Powiązania:
https://bibliotekanauki.pl/articles/1399411.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
88.50.jj
88.50.gp
43.40.At
Opis:
Results of a measurement and analysis of vibro-acoustic signals generated by two low power vertical-axis wind turbines that are installed on the roof of the Electric Power Institute at Opole University of Technology are presented in the paper. The study considers a Darrieus and a Savonius type wind turbines of rated power 1 kW each. For registration of the vibrations of the turbine mast three uniaxial accelerometers and a measurement equipment from Brüel & Kjær were applied. The measurement setup is presented in the paper. A comparative analysis of the registered data in the time and time-frequency domains was performed. Results depict changes in the recorded signals in time and frequency under different meteorological conditions, i.e. for different wind speed values. Based on the achieved results significant differences in the mast vibrations of the two kinds of wind turbines were stated.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 595-597
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza hałasu infradźwiękowego emitowanego przez turbiny wiatrowe różnych mocy
Comparative analysis of infrasound noise emitted by wind turbines of various power
Autorzy:
Malec, T.
Boczar, T.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/157892.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
turbiny wiatrowe
hałas
infradźwięki
wind turbines
noise
infrasound
Opis:
W ramach artykułu przedstawiono wyniki analizy porównawczej poziomu ciśnienia akustycznego hałasu infradźwiękowego generowanego przez dwie turbiny wiatrowe dużych mocy tj. fabrycznie nowej REPOWER typ MM92 o mocy elektrycznej 2 MW i eksploatowanej od pięciu lat Vensys typ 62 o mocy elektrycznej 1,2 MW. W części wynikowej przedstawiono przebiegi widm częstotliwościowych i spektrogramów, które wyznaczono dla zarejestrowanych sygnałów niskoczęstotliwościowych. W celach porównawczych charakterystyki obliczono oddzielnie dla badanych turbin z uwzględnieni m/s. Pozwoliło to określić wielkość oddziaływania infradźwiękowego badanych turbin i zbadać czy na kształt widm emitowanego hałasu wpływa prędkość wiatru oraz konstrukcja, typ i czas eksploatacji badanych turbin. Uzyskane z pomiarów wielkości zostały odniesione i porównane z wartościami granicznymi określonymi w obwiązujących w tym zakresie normami.
The subject area of this paper is infrasound signals generated by work of modern wind turbines. Measurements of infrasound noise were taken in accordance with the PN-EN 61400-11:2002 [7] and PN-EN 61400-11:2004/A1 [8] standards. A comparative analysis of the measurement results of the infrasound noise generated by two types of high-power wind turbines i.e. REPOWER MM92 of electric power 2 MW and Vensys 62 of electric power of 1.2 MW is presented in the paper. The first studied turbine is brand new and the other has been in operation for five years. The aim of the analyzes was to determine the frequency spectra of the recorded infrasound signals (Figs. 6, 7, 10, 13, 16) and to calculate the corresponding spectrograms (Figs. 8, 9, 11, 12, 14, 15). For comparative purposes, the characteristics presented in this paper, were calculated separately for the analyzed turbines taking into account three selected values of wind speed: 5. m/s, 6.3 m/s and 7.6 m/s. On the basis of the obtained results the influence of wind speed changes on the generated levels of low-frequency acoustic signals was determined. Then, the dependencies obtained from measurements were referred and compared to the limits defined in the appropriate standards.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 9, 9; 773-778
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu warunków meteorologicznych na sprawność turbin wiatrowych
Evaluation of the influence of weather conditions on the efficiency of wind turbines
Autorzy:
Boczar, T.
Szczyrba, T.
Powiązania:
https://bibliotekanauki.pl/articles/155905.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
turbiny wiatrowe
elektrownie wiatrowe
warunki atmosferyczne
sprawność
wydajność
efektywność
wind turbines
weather conditions
efficiency
effectiveness
productivity
Opis:
Podstawowym celem przeprowadzonych badań było określenie wpływu zmian gęstości powietrza atmosferycznego na wyniki obliczeń wskaźników charakteryzujących sprawność elektrowni wiatrowych. W części wynikowej przedstawiono wykresy obrazujące wpływ zarejestrowanych parametrów atmosferycznych na przebiegi krzywej mocy i wartości sprawności. Zależności zostały wyznaczone na podstawie rejestracji temperatury, ciśnienia i wilgotności powietrza atmosferycznego, które wykonano dla dwóch turbin wiatrowych Tacke Tw 600.
The main objective of the studies whose results are presented in this paper was to determine the impact of air density changes on the calculation results of indicators characterizing the efficiency of a wind power plant. It was assumed that the efficiency is described by the amount of electricity generated in a specified period of time, under existing weather conditions for the given location and when taking into account the generated energy quality and the real efficiency of components of the wind turbine generators and their control systems. The equipment used for measuring purposes, location of measuring instruments and their calibration methods are characterized in the descriptive part of the paper. Additionally, basic recommendations on the methodology of measuring the ambient air temperature, pressure and humidity in order to determine the wind turbine efficiency are given. In the part of the paper presenting the results there are shown the graphs illustrating the impact of the recorded atmospheric parameters on the courses of the empirical power curve and the real efficiency value. The dependencies were determined on the basis of the recorded ambient air values of temperature, pressure and humidity in summer, autumn and winter periods for the two Tacke Tw 600 wind turbines. Respectively, Figs. 2-5 show the graphs presenting the impact of changes of the recorded air temperature, atmospheric pressure, relative humidity and air density on the course of the empirical power curve and the real efficiency value (Fig. 6) of the wind turbines being studied.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 12, 12; 1044-1047
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies