Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Michnik, Andrzej" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Assessment of gait stability and preferred walking speed in virtual reality
Autorzy:
Wodarski, Piotr
Jurkojć, Jacek
Polechoński, Jacek
Bieniek, Andrzej
Chrzan, Miłosz
Michnik, Robert
Gzik, Marek
Powiązania:
https://bibliotekanauki.pl/articles/306508.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
stabilność chodu
chód na bieżni
prędkość marszu
gait stability
gait on treadmill
preferred walking speed
gait variability
Opis:
Analysis of human gait as well as diagnosis of human locomotion organ should always be conducted with velocity of gait equal to Preferred Walking Speed (PWS). The literature review shows that the PWS value is not the same in real and virtual environment. The aim of this study was to determine PWS values in both environments and to specify values of parameters used in equations enabling PWS calculations on the basis of lower limb length. Methods: Research-related tests involved 40 subjects walking on the treadmill and wearing HMD goggles. The spatial scenery made participants feel like during a walk in the park. The tests included measurements of displacements of the COP, allowing for the calculation of the Lyapunov exponent and Floquet Multiplier. Both coefficients were used to identify stability at various gait velocities. Results: The analysis revealed that the PWS in relation to gait on the treadmill with VR was lower than the PWS without VR. The final stage of research involved the determination of new values of coefficients of the formula enabling the identification of the velocity of comfort of gait in VR. Conclusions: Obtained results proved that PWS in real and virtual environment are different. The lower values were obtained for measurements in VR. On the basis of these results, value of the “a” coefficient, used in PWS calculations on the basis of lower limb length, was re-determined. The new value makes it possible to assess PWS for gait conducted on treadmill in virtual environment, what can be very important in gait evaluation.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 1; 127-134
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Depth and rate of chest compression in CPR simulation during 10-minute continuous external cardiac compression
Ocena głębokości i częstotliwości kompresji klatki piersiowej podczas symulacji resuscytacji krążeniowo-oddechowej, w trakcie 10-minutowego ciągłego zewnętrznego masażu serca
Autorzy:
Bucki, Bogusław
Karpe, Jacek
Michnik, Robert
Niczyporuk, Arkadiusz
Makarska, Joanna
Waniczek, Dariusz
Bieniek, Andrzej
Misiołek, Hanna
Powiązania:
https://bibliotekanauki.pl/articles/1036201.pdf
Data publikacji:
2017
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
chest compression
cardiopulmonary resuscitation
professional rescuers
kompresja klatki piersiowej
resuscytacja krążeniowo-oddechowa
profesjonalni ratownicy
Opis:
INTRODUCTION: External cardiac massage has been a basic CPR maneuver for years. The aim of the study was to assess the quality of chest compression during a real-time continuous cardiac compression simulation on a cardio-pulmonary resuscitation mannequin (considering medical rescuer experience and BMI). MATERIAL AND METHODS: This was a prospective study involving 17 medical rescuers, and 21 Medical Rescue stu-dents and university lecturers. During the simulation the participants performed continuous external cardiac compres-sion for 15 minutes or until the refusal to continue. The depth and rate were analyzed at 60-second periods, leading to average values of cardiopulmonary resuscitation effectiveness. The analysis covered complete research data gathered in real time (10 minute periods). RESULTS: The average compression depth significantly decreased from the first (40.66 SE ± 0.80 mm) to the fourth minute of the study (38.21 SE ± 0.95 mm). The average compression rate was significantly different between the initial values (120.97 SE ± 2.83/min) and the sixth minute of the study (123.69 SE ± 2.55/min). The average com-pression depth amounted to n 36.03 SE ± 1.22 mm in non-professionals and 40.06 SE ± 1.37 mm in professionally active participants. In the participants with a BMI > 25, the only differentiating point in time was the beginning of the task when the average compression depth was 41.97 SE ± 1.12 mm. In the participants with a BMI < 25, there was a gradual decrease in the compression depth within the initial four minutes of the task. CONCLUSION: Rescuer body mass is an important factor influencing proper chest compression depth during conti-nuous cardiac compression. Professional rescuers are capable of performing continuous cardiac compression longer than non-professionals, at the same time maintaining acceptable sternum deflection and compression rate.
WSTĘP: Celem pracy była prospektywna ocena jakości kompresji klatki piersiowej podczas symulacji ciągłego masażu serca na manekinie w czasie rzeczywistym, wykonywanego przez czynnych zawodowo ratowników medycznych, z uwzględnieniem ich BMI. MATERIAŁ I METODA: Badanie przeprowadzono w grupie 17 ratowników medycznych oraz 21 studentów kierunku ratownictwo medyczne i wykładowców uczelni. Podczas próby każdy badany wykonywał nieprzerywany masaż ze-wnętrzny serca na manekinie do osiągnięcia punktu końcowego, jakim był czas 15 minut lub odmowa dalszego wy-konywania zadania. WYNIKI: Średnia głębokość wykonywanych uciśnięć zmniejszała się istotnie od pierwszej (40,66, SE ± 0,80 mm) do czwartej minuty badania, osiągając wartość 38,21 SE ± 0,95 mm. Średnia częstość uciśnięć klatki piersiowej istotnie różniła się od szóstej minuty (123,69 SE ± 2,55/min) w stosunku do wartości wyjściowych (120,97 SE ± 2,83/min). W dziesiątej minucie średnie wartości głębokości uciśnięć oraz częstości masażu klatki piersiowej osiągnęły odpo-wiednio 36,62 SE ± 1,04 mm oraz 128,06 SE ± 2,43/min. Istotnym czynnikiem wpływającym na głębokość kompresji klatki piersiowej była przynależność do grupy czynnych zawodowo ratowników medycznych. Średnia głębokość ucisku w całym badanym przedziale czasowym w grupie nie-profesjonalistów wynosiła 36,03 SE ± 1,22 mm, podczas gdy w grupie profesjonalistów – 40,06 SE ± 1,37 mm. Drugim istotnym czynnikiem różnicującymi zakres głębokości kompresji klatki piersiowej był czas oraz BMI ratow-nika. U osób z BMI > 25 jedynym różnicującym punktem czasowym był początek badania, w którym średnia głębo-kość ucisku wynosiła 41,97 SE ± 1,12 mm. WNIOSKI: Masa ciała ratownika jest istotnym czynnikiem wpływającym na uzyskanie głębszej kompresji klatki pier-siowej. Profesjonalni ratownicy są w stanie prowadzić skutecznie ciągłą kompresję klatki piersiowej w dłuższym czasie, osiągając zadowalające ugięcie oraz częstotliwość jej kompresji.
Źródło:
Annales Academiae Medicae Silesiensis; 2017, 71; 1-6
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies