Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wirnik" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Silniki klatkowe dużej mocy do często powtarzanych lub długo trwających rozruchów
Big capacity squirrel cage motors for frequently repeated or long lasting starts
Autorzy:
Bernatt, J.
Bernatt, M.
Powiązania:
https://bibliotekanauki.pl/articles/1369373.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki klatkowe
rozruch
wirnik silnika
Opis:
High capacity induction squirrel cage motors used at different industrial driver are usually started by switching direct on line. Starting current, several times higher than nominal load current, causes thermal and mechanical, dynamic stresses dangerous for motor's structure. Both, stator and rotor windings are endangered at starting period, but stresses in rotor cages are usually considerable higher, therefore rotor design (and its manufacturing process) is of high importance for motor's durability.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 4, 97; 43-47
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O uszkodzeniach klatek wirnika
Rotor cage failures
Autorzy:
Bernatt, M.
Rut, R.
Mróz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1374154.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
uszkodzenie klatki wirnika
wirnik
silniki elektryczne
Opis:
Rotor cage failures are not regarded as the main cause of the induction motors breakdowns. An induction motor with broken squirrel cage bars can still be exploited, consecutive starts may be executed. At durability tests carried out by Komel Centre some years ago on a prototype 800 kW induction motor, it was stated, that even if 80% of the rotor bars were broken, the motor started fairy successfully and could be loaded. But any rotor cage failure (e.g. single bar or end ring fracture) causes electromagnetic asymmetry of the motor; main technical features of the motor are heavily deteriorated. Sound power level and vibration level become higher, efficiency factor lower, temperature rise of the stator winding may by higher. Starting (locked rotor) and breakdown torque is lower. In the paper special laboratory tests of a standard, 4 kW, 1500 RMP, 3 phase motor with aluminium rotor cast are presented. The tests were carried out on symmetric ("healthy") squirrel cage and on the cage with one, three and six broken bars. Several examples of large AC motors with damaged rotors and a reliable method for rotor squirrel cage diagnostics are presented.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2008, 79; 7-12
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Silniki wysokiego napięcia dla trudnych warunków eksploatacyjnych. (Projektowanie i wykonawstwo)
High voltage AC motors for hard working conditions. (Design and manufacture)
Autorzy:
Bernatt, M.
Poprawski, W.
Powiązania:
https://bibliotekanauki.pl/articles/1372918.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki wysokiego napięcia
wirnik
eksploatacja silnika elektrycznego
Opis:
High voltage (6000 and 10000 V) AC squirrel cage motors are started by switching direct on line. The inrush of starting current causes mechanical and thermal stresses in the motor structure, mainly in their rotor's cage. Motors for hard working conditions, esp. for high frequency of starts, or for long lasting starts should be designed and manufactured especially. At Komel Centre several calculation and designing methods for motors exploited at hard working and starting conditions were elaborated. Many motors of this kind were designed by Komel and manufactured by polish manufacturers. The motors were exploited several years in various branches of industry without any breakdowns. In the paper three cause studies are presented: 550, 800, and 2000 kW motors, where redesigning and replacing only their rotors were full satisfactory.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 85; 1-5
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja i poprawa parametrów silników elektrycznych dużej mocy podczas remontu
Modernization and performance data upgrading of high power electric motors at their repair process
Autorzy:
Bernatt, J.
Bernatt, M.
Powiązania:
https://bibliotekanauki.pl/articles/1197525.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
wirnik klatkowy
modernizacja
electric machines
squirrel cage rotor
redesigning
Opis:
The paper presents a possibility of improving perf ormance data and durability in exploitation of high power electric motors at their repair process. Some redesigning of the motors may be necessary. Examples of redesigned squirrel cage motor output up to 3200 kW are given. As a result increasing of durability for hard staring conditions (frequent or long lasting starts of the motor), diminishing the noise level or increasing of efficiency level of the redesigned motors were a chieved.
W artykule przedstawiono możliwość znaczącej poprawy parametrów technicznych (w tym również trwałości eksploatacyjnej) silników elektrycznych dużej mocy, którą można osiągnąć w trakcie remontu. Do osiągnięcia tego konieczne są jednak pewne zmiany projektowo- konstrukcyjne w remontowanym silniku. Podano przykłady dla silników klatkowych mocy do 3200 kW
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 1, 117; 9-13
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies