Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "więzadło krzyżowe" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Effect of preservation methods on tensile properties of human femur-ACL-tibial complex (FATC) – a cadaveric study on male subjects
Autorzy:
Marieswaran, M.
Mansoori, N.
Digge, V. K.
Jhahjhria, S. K.
Behera, C.
Lalwani, S.
Kalyanasundaram, D.
Powiązania:
https://bibliotekanauki.pl/articles/306817.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
przechowywanie w formalinie
mrożenie głębokie
FATC
więzadło krzyżowe przednie
rozciąganie
tissue preservation
storage in formalin
deep freezing
anterior cruciate ligament
biomechanical study
tensile testing
Opis:
Deep freezing and storing in formalin are some of the common techniques of human tissue preservation. However, the preservation modes affect the biomechanical properties of the tissues. In this work, the effects of the above-stated preservation techniques are compared with that of fresh cadaveric samples. Methods: FATC samples from male cadavers of age between 60 and 70 years were tested under tensile loading at a strain rate of 0.8 s–1. Fourteen FATC samples from soft embalmed cadavers were preserved for 3 weeks by two methods: (a) 10% formalin and (b) deep freezing at –20 C followed by thawing. Seven FATC samples from fresh cadavers were experimented as control samples. The results were evaluated by a two-stage statistical process of Kruskal–Wallis H test and Mann–Whitney U-test. Results: It was observed that the failure force of fresh cadavers was the highest while that of preserved samples were approximately half the value. Failure elongation of frozen samples exceeded fresh samples while formalin samples failed at lesser elongations. Higher incidence of tibial insertion point or mid-section failures were observed in fresh samples while the higher incidence of ruptures at femoral insertion point was observed in the two preservation methods. Conclusion: Tensile properties of fresh tissues vary significantly from that of formalin preserved or frozen preserved samples.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 3; 31-42
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies