Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Jasinska-Choromanska, D." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Experimental studies of the quality of embossed characters of the Braille alphabet
Autorzy:
Barczyk, R.
Jasińska-Choromańska, D.
Powiązania:
https://bibliotekanauki.pl/articles/200563.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tactile reading
Braille alphabet
Braille characters
visual impairment
measurement of parameters of Braille dots
czytanie dotykowe
alfabet Braille'a
znaki Braille'a
niedowidzenie
pomiar parametrów kropek brajlowskich
Opis:
The paper presents studies pertaining to the quality of embossed characters of the Braille alphabet used, among other applications, for tagging drug labels. The following parameters of embossed inscriptions were measured: height, diameter of the dots and surface roughness (18 samples with various combinations of their values). 48 blind individuals assessed the quality of the printed text. Statistical analysis proved that a text with dots having height of 0.9 millimeter, diameter of 1.6 millimeters and roughness Ra of about 1 micrometer to be the best. The samples had been made using two different methods of rapid prototyping: PolyJet and SLS. 3D printing is increasingly popular and the studies proved the usefulness of these methods for labeling with embossed inscriptions, due to the repeatability, durability and quality they ensure. The assessing group of blind individuals was comprised of 24 persons 14–17 years old and other 24 persons aged over 60 who were not proficient in reading Braille alphabet, This allows to conclude that a text featuring the above values of the parameters will be easy to read for the majority of blind persons.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 3; 607-614
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measuring of the Basic Parameters of LCD Displays
Autorzy:
Barczyk, R.
Kabzinski, B.
Jasinska-Choromanska, D.
Stienss, A.
Powiązania:
https://bibliotekanauki.pl/articles/384703.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
LCD
parameter
contrast ratio
view angle
luminance
measurement
Opis:
This article is about realization of the laboratory stand used for measuring parameters of LCD displays. The stand together with additional accessories (spectrophotometer and measuring probes) as well as software allow to measure a wide range of parameters (colour gamut, response time, contrast coefficient and its irregularity, luminance of black colour and its irregularity, luminance of white colour and its irregularity, changes of luminance depending on the viewing angle). This paper also show method and results of measurements of differences in contrast ratio and luminance uniformity between particular pieces of the same model of a display screen (research has been carried out on 5 pieces of the same model of a display). The presented results show that the measured value of the viewing angle may significantly differ from the value provided by producers of displays.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 1; 46-48
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt stanowiska badawczego do pomiarów pionowych i poziomych kątów widzenia monitorów LCD
Project of the research stand for measuring horizontal and vertical viewing angles of LCD displays
Autorzy:
Barczyk, R.
Jasińska-Choromańska, D
Kabziński, B.
Stienss, A.
Powiązania:
https://bibliotekanauki.pl/articles/152624.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
monitor LCD
kąt widzenia
stanowisko pomiarowe
luminancja
LCD displays
viewing angle
measuring stand
Opis:
W artykule przedstawiono projekt oraz realizację stanowiska pomiarowego służącego do pomiarów kątów patrzenia monitorów LCD. Przedstawione zostały założenia, które przyjęto na etapie projektu, zgodność z normami ISO oraz przykładowe wyniki pomiarów. Przedstawione wyniki pomiarów pokazują, że zmierzona wartość kąta patrzenia może się znacznie różnić od wartości podawanej przez producenta monitora.
The paper deals with project and realization of a laboratory stand for measuring viewing angles of LCD displays. There is a need to build such stands in order to check whether the parameters of displays reflect the ones provided by their producers. The ISO norms guidelines as regards tests of displays (ISO 9241-303:2008 "Ergonomics of human-system interaction - Part 303: Requirements for electronic visual displays" and ISO 9241-305:2008 "Ergonomics of human-system interaction - Part 305: Optical laboratory test methods for electronic visual displays") were used to make sure that the results of such research were reliable. The stand together with additional accessories (spectrophotometer and measuring probes) as well as software allow measuring a wide range of parameters (colour gamut, response time, contrast coefficient and its irregularity, luminance of black colour and its irregularity, luminance of white colour and its irregularity, changes of luminance depending on the viewing angle). In this paper there is described the stand construction as well as the method for measuring the luminance change depending on the viewing angles, which is one of the most important parameters in the situation when there are several people looking at a certain screen. The presented measurement results also show differences between particular pieces of the same model of a display screen (investigations were performed on 5 pieces of the same model of a display). The presented results show that the measured value of the viewing angle may significantly differ from the value provided by producers of displays.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 9, 9; 981-984
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary równomierności oświetlenia matryc LCD
Illumination equality measurement of LCD matrices
Autorzy:
Barczyk, R.
Kabziński, B.
Jasińska-Choromańska, D
Stienss, A.
Powiązania:
https://bibliotekanauki.pl/articles/153712.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
monitory LCD
luminancja
współczynnik kontrastowości
nierównomierność
kontrast
LCD
monitor
luminance
contrast ratio
uniformity
Opis:
Artykuł porusza kwestie pomiaru równomierności oświetlenia oraz parametrów związanych z tym zjawiskiem: współczynnika kontrastowości, nierównomierności kontrastu, luminancji i jej nierównomierności. Przedstawia powody, dla których te parametry są istotne pod względem użytkowym, oraz opisuje metody, jakimi można badać wymienione powyżej parametry. Przedstawia wyniki badań wykonanych na próbie pięciu monitorów tego samego modelu.
The illumination uniformity in LCD monitors is analyzed in the paper. The phenomenon is described and explained by taking into consideration the following parameters: contrast ratio, luminance, uniformity of display contrast, and luminance. No defined measurement method of these values exists (except partially different standards by ISO, VESA, ANSI). The method which unify and minimize measurements is described in the paper. The same measurement points are used to measure all parameters under consideration. Luminance measurements are made in a dark room, on center of a screen surface emitting white color. The same is also used in uniformity measurement (Eq. 1). It describes luminosity difference values in different places of monitor. Contrast ratio (Eq. 2) measurements were made using electronic set of photodiode and transimpedance amplifier in one structure (Fig. 2). Uniformity measurement of display contrast have been made in few points, defined by VESA organization (Figs. 3, 4, 5, 6). 5 monitors of the same model were tested (Tab. 1). Contrast ratio show significant difference for each monitor and between each other. Similar results are for luminance and luminance uniformity (Tab. 4) where difference in uniformity reached almost 40%. Type of monitor backlight is main cause of poor uniformity, but also quality of LCD matrices may have influence on overall comfort of using such moni-tors. The results show that luminance and contrast uniformity should be given in technical specification of products.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1355-1358
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies