Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "direct integration" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Analysis of scaffolding harmonic excitation
Autorzy:
Bęc, Jarosław
Błazik-Borowa, Ewa
Szer, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2204503.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
scaffolding
harmonic excitation
dynamic analysis
direct integration
rusztowanie
wzbudzenie harmoniczne
analiza dynamiczna
integracja bezpośrednia
Opis:
Scaffolding is equipment usually used at construction sites. A scaffolding structure is lightweight and made of elements used many times. The characteristics of scaffolding make it susceptible to dynamic actions present at the structure or occurring nearby. A scaffolding structure of medium size was subjected to analysis in this paper. The structure FEM model was loaded with single force harmonic excitation with various frequencies ranging from 1 Hz to 12 Hz applied in one of many selected points on the scaffolding façade. In the first step, natural frequencies and mode shapes of the analyzed structure were calculated. Then the full dynamic analysis was carried out to obtain maximum displacements of selected control points. The relation of excitation force frequency and location to the amplitudes of generated displacement was observed. It was found that low excitation frequencies close to the natural frequencies of the structure produced vibrations ranging to large areas of the scaffolding surface. Higher excitation frequencies are usually less propagated at the scaffolding but still may produce some discomfort to the structure users in the vicinity of the excitation force location. Scaffolding is equipment usually used at construction sites. A scaffolding structure is lightweight and made of elements used many times. The characteristics of scaffolding make it susceptible to dynamic actions present at the structure or occurring nearby. A scaffolding structure of medium size was subjected to analysis in this paper. The structure FEM model was loaded with single force harmonic excitation with various frequencies ranging from 1 Hz to 12 Hz applied in one of many selected points on the scaffolding façade. In the first step, natural frequencies and mode shapes of the analyzed structure were calculated. Then the full dynamic analysis was carried out to obtain maximum displacements of selected control points. The relation of excitation force frequency and location to the amplitudes of generated displacement was observed. It was found that low excitation frequencies close to the natural frequencies of the structure produced vibrations ranging to large areas of the scaffolding surface. Higher excitation frequencies are usually less propagated at the scaffolding but still may produce some discomfort to the structure users in the vicinity of the excitation force location.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 1; art. no. e144577
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies