Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "distribution" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Analysis of sectionalizing switch placement in medium voltage distribution networks in the aspect of improving the continuity of power supply
Autorzy:
Bąchorek, W.
Benesz, M.
Powiązania:
https://bibliotekanauki.pl/articles/201362.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
reliability of distribution networks
sectionalizing switches
SAIDI
Opis:
The paper addresses the problem of placement of sectionalizing switches in medium voltage distribution networks. Proper placement of sectionalizing switches is one of the elements leading to higher power networks reliability. The methods of optimal allocation of such switches in a MV distribution network are presented in the paper. SAIDI was used as a criterion for the sectionalizing switches placement. For selecting optimum placements, three methods were used: brute force method, evolutionary algorithm and heuristic algorithm. The calculations were performed for a real MV network.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 3; 459-466
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybór optymalnej strategii eksploatacji stacji transformatorowych w sieciach rozdzielczych SN
Choosing optimal strategy for exploitation of transformer station in medium voltage distribution networks
Autorzy:
Gancarz, A.
Bąchorek, W.
Powiązania:
https://bibliotekanauki.pl/articles/267972.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
elektroenergetyczne sieci rozdzielcze
optymalizacja
algorytmy ewolucyjne
power distribution networks
optimization
evolutionary algorithm
Opis:
W referacie zaproponowano rozwiązanie problemu optymalnej gospodarki majątkiem sieciowym na przykładzie wymiany transformatorów dla wybranego fragmentu sieci rozdzielczej jednej ze Spółek Dystrybucyjnych. Przedstawia się algorytm obliczeniowy, jego implementację komputerową oraz przykład obliczeniowy.
The article concerns the problem of optimal management the property of Electrical Power Distribution Companies. The analysed task concerns the problem of exchange of MV/LV transformers for selected power distribution networks. Computational algorithm, computer implementation as well as computational example was introduced.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 25; 41-44
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimisation of Reactive Power Compensation, Selected Results for Medium Voltage Distribution Networks
Optymalizacja kompensacji mocy biernej, wybrane wyniki dla sieci rozdzielczych średniego napięcia
Autorzy:
Szpyra, W.
Bąchorek, W.
Kot, A.
Powiązania:
https://bibliotekanauki.pl/articles/396858.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
power distribution networks
reactive power compensation
optimisation
elektroenergetyczne sieci rozdzielcze
kompensacja mocy biernej
optymalizacja
Opis:
This paper concerns issues of optimal location of reactive power sources in radial MV distribution networks. At first, the optimisation problem is formulated along with constraints, and solution methods are indicated. Data necessary to  perform calculations and used assumptions is discussed. Optimisation calculations have been performed for many real MV networks; their essential parameters are presented in the paper along with the characteristics of the obtained results. The paper ends with a summary which presents conclusions of the performed analyses.
Artykuł poświęcony jest problematyce optymalnego rozmieszczenia źródeł mocy biernej w otwartych sieciach rozdzielczych SN. Na początku sformułowano zadanie optymalizacji wraz z warunkami ograniczającymi oraz wskazano metody jego rozwiązania. Omówiono dane niezbędne do wykonania obliczeń oraz przyjmowane założenia. Dokonano obliczeń optymalizacyjnych dla wielu rzeczywistych sieci SN, których podstawowe dane wraz z charakterystykami uzyskanych rozwiązań zaprezentowano w pracy. Artykuł kończy podsumowanie zawierające wnioski z wykonanych analiz.
Źródło:
Acta Energetica; 2015, 3; 119-129
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zadanie optymalnej kompensacji mocy biernej w sieciach rozdzielczych średniego napięcia - krótka charaktertystka rozwiazań
Optimal reactive power compensation in medium voltage networks – short solutions characteristic
Autorzy:
Szpyra, W.
Bąchorek, W.
Kot, A.
Powiązania:
https://bibliotekanauki.pl/articles/267715.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
elektroenergetyczne sieci rozdzielcze
kompensacja mocy biernej
optymalizacja
power distribution networks
reactive power compensation
optimization
Opis:
Referat poświęcony jest problematyce optymalnego rozmieszczenia źródeł mocy biernej w otwartych sieciach rozdzielczych średniego napięcia (SN). W referacie sformułowano zadanie optymalizacji wraz z warunkami ograniczającymi oraz wskazano metody jego rozwiązania. Omówiono dane niezbędne do wykonania obliczeń oraz przyjmowane założenia. Dokonano obliczeń optymalizacyjnych dla szeregu rzeczywistych sieci SN, których podstawowe dane wraz z charakterystykami uzyskanych rozwiązań zaprezentowano w referacie. Pracę kończy podsumowanie zawierające wnioski z wykonanych analiz.
The paper addresses the problem of optimal reactive power compensation in a distribution network. In general, the optimal solution to reactive power compensation problem relies upon finding the location, size of capacitors and their working time at which the adopted objective function reaches its extreme. The method proposed in this paper maximizes the profit resulting from the reduction of network losses. Additionally, the optimal solution should meet specified constraints. The constraints include: maintaining voltage levels within acceptable limits, not overloading network elements, and limiting the power of capacitors to prevent overcompensation. As a measure of the economic efficiency of solutions the net present value ratio (NPVR) was assumed. The NPVR cannot be used as an objective function because the addition of next capacitor decreases the value of NPVR in the iterative process. We developed two optimization algorithms for solving the task: heuristic and evolutionary. This paper presents selected results of numerical studies for 9 real polish distribution networks fed by a 110/15 kV transformer.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 97-100
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie komputerów do wieloetapowej optymalizacji pracystacji transformatorowych średniego napięcia
Application of computers in multistage optimization of middle voltage transformer station utilization
Autorzy:
Gancarz, A.
Bąchorek, W.
Powiązania:
https://bibliotekanauki.pl/articles/268344.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
elektroenergetyczne sieci rozdzielcze
optymalizacja wieloetapowa
algorytmy ewolucyjne
power distribution networks
multistage optimization
evolutionary algorithm
Opis:
Projektowanie struktur elektroenergetycznych sieci rozdzielczych wiąże się z przyjęciem ustalonego okresu optymalizacji oraz prognozy zmian obciążeń w tym okresie. Właściwe jest w takim przypadku rozłożenie wszelkich przewidywanych działań na różne momenty optymalizowanego okresu. W artykule przedstawia się metodę optymalizacji wieloetapowej zadania doboru transformatorów w sieci rozdzielczej średniego napięcia. Przestawiono algorytm obliczeniowy, jego implementację komputerową oraz przykład obliczeniowy dla fragmentu sieci rozdzielczej.
The analysed task concerns the problem of exchange of MV/LV transformers for selected power distribution networks. The article concerns the problem of multistage optimization. Computational algorithm, computer implementation as well as computational example was introduced.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 41-44
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability improvement of power distribution line exposed to extreme icing in Poland
Autorzy:
Ciesielka, W.
Gołaś, A.
Szopa, K.
Bąchorek, W.
Benesz, M.
Kot, A.
Moskwa, S.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/200660.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power distribution networks
overhead lines
finite element method
reliability
icing
rime
prevention of line icing
Opis:
Currently, overhead lines dominate in the Polish medium and low voltage distribution networks. Maintaining their high reliability constitutes a very important challenge, especially under the severely changing climate conditions. An overhead power line exposed to high ice and rime loads has been considered. Using the finite element method (FEM), mechanical reliability of the distribution infrastructure was examined under various atmospheric conditions. Loads under the stressful conditions of rime, ice and wind were determined for the weakest section of the 30 kV overhead line, which consisted of concrete poles and ACSR conductors. SAIDI and SAIFI reliability indices and costs were determined for several variants of object reconstruction. The results allowed for determination of a solution relying on relocating the cables of all lateral branches and main line ice protection, through a system based on a weather-coordinated increase of the electrical load. To verify the solution proposed, a field experiment was conducted. The experiment confirmed the effectiveness of the solution proposed that appears to be universal. The paper is a result of synergic cooperation of two academic teams, i.e. a mechanical and electrical power engineering one, and the Distribution System Operator (DSO).
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 5; 1113-1125
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane problemy ograniczania strat mocy i energii w sieciach dystrybucyjnych
Selected problems of minimizing power and energy loss in distribution networks
Autorzy:
Brożek, J.
Bąchorek, W.
Powiązania:
https://bibliotekanauki.pl/articles/266792.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
elektroenergetyczna sieć dystrybucyjna
straty mocy i energii
electric power distribution network
power and energy loss
Opis:
Stacje transformatorowe średniego napięcia na niskie napięcie (SN/nn) spełniają podobną rolę w sieciach niskiego napięcia jak główne punkty zasilania (GPZ) w sieci średniego napięcia. Budowa nowej stacji transformatorowej SN/nn zmienia warunki pracy elektroenergetycznej sieci rozdzielczej na danym terenie poprzez: . zmniejszenie długości ciągów sieci dystrybucyjnej nn, . zmiany w rozpływie prądów, . zmniejszenie spadków napięcia, . zmniejszenie strat mocy i energii w istniejącym układzie, . zwiększenie pewności zasilania. W referacie przedstawiono wyniki obliczeń strat mocy i energii dla różnych stanów pracy sieci dystrybucyjnej niskiego napięcia. Do analizy strat mocy i energii w sieci rozdzielczej nn zastosowano model liniowy sieci. Praca stanowi kontynuację tematu zawartego w pracy [1].
In the paper there are presented selected methods of minimizing power and energy loss in low-voltage networks feeding rural and suburban areas. The analysis is carried out with the use of a linear model of the network with a uniform power load along the network tracks. In order to decrease the energy loss (per one recipient) in a network with linear load (Fig. 2) one should avoid the feeding of too small a number of loads from one MV/LV transformer station (the number of connected loads should exceed 18-22). The calculations have shown that the construction of an additional feeding point usually leads to the decrease of the power and energy loss.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2011, 30; 21-24
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kryteria optymalnej kompensacji mocy biernej w sieciach dystrybucyjnych
Optimisation criteria for reactive power compensation in distribution networks
Autorzy:
Szpyra, W.
Bąchorek, W.
Kot, A.
Makuch, A.
Powiązania:
https://bibliotekanauki.pl/articles/952795.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kompensacja mocy biernej
kryteria optymalizacji
elektroenergetyczne sieci rozdzielcze
reactive power compensation
optimization criteria
power distribution networks
Opis:
W artykule zwrócono uwagę na skutki przesyłania mocy biernej, podano zależności pozwalające na obliczenie efektów i kosztów kompensacji oraz omówiono wybrane metody oceny efektywności ekonomicznej. Przedstawiono wyniki obliczeń skutków różnych wariantów kompensacji mocy biernej w rzeczywistym obwodzie sieci średniego napięcia. Otrzymane wyniki wskazują, że osiągnięcie maksymalnego zysku z ograniczenia strat, w wyniku kompensacji mocy biernej, niekoniecznie musi wskazywać na rozwiązanie najbardziej efektywne z ekonomicznego punktu widzenia.
This paper describes the effects of reactive power flow through the power transmission and distribution networks. It also presents the dependencies allowing to calculate the costs and effects of reactive power compensation. Additionally selected methods for assessing economic efficiency were discussed. The paper presents calculation results for different variants of reactive power compensation in a real, medium voltage feeder. The results indicate that maximum profit from the reduction of losses due to reactive power compensation does not necessarily mean the most efficient solution from the economic point of view.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 33; 103-106
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization Criteria for Reactive Power Compensation in Distribution Networks
Kryteria optymalnej kompensacji mocy biernej w sieciach dystrybucyjnych
Autorzy:
Szpyra, W.
Bąchorek, W.
Kot, A.
Makuch, A.
Powiązania:
https://bibliotekanauki.pl/articles/397567.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
kompensacja mocy biernej
kryteria optymalizacji
elektroenergetyczne sieci rozdzielcze
reactive power compensation
optimization criteria
power distribution networks
Opis:
This paper describes the effects of reactive power flow through the power transmission and distribution networks. It also presents the dependencies allowing calculating the costs and effects of reactive power compensation. Additionally, selected methods for assessing economic efficiency were discussed. The paper presents calculation results for different variants of reactive power compensation in a real, medium voltage feeder. The results indicate that maximum profit from the reduction of losses due to reactive power compensation does not necessarily mean the most efficient solution from the economic point of view.
W artykule autorzy omówili skutki przesyłania mocy biernej, podano zależności pozwalające na obliczenie efektów i kosztów kompensacji oraz omówiono wybrane metody oceny efektywności ekonomicznej. Przedstawiono wyniki obliczeń skutków różnych wariantów kompensacji mocy biernej w rzeczywistym obwodzie sieci średniego napięcia. Otrzymane wyniki wskazują, że osiągnięcie maksymalnego zysku z ograniczenia strat, w wyniku kompensacji mocy biernej, nie musi wskazywać na rozwiązanie najbardziej efektywne z ekonomicznego punktu widzenia.
Źródło:
Acta Energetica; 2014, 4; 140-155
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Straty mocy w sieciach dystrybucyjnych z generacją rozproszoną
Power loss in distribution networks with dispersed generation
Autorzy:
Brożek, J.
Bąchorek, W.
Szpyra, W.
Powiązania:
https://bibliotekanauki.pl/articles/266694.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
elektroenergetyczna sieć dystrybucyjna
straty mocy i energii
źródła rozproszone
electric power distribution network
power loss
dispersed generation
Opis:
Wprowadzenie dodatkowego źródła mocy czynnej (generacji rozproszonej GR) do układu zasilania elektroenergetycznej sieci średniego napięcia zmienia jej stan pracy. Praca dodatkowych źródeł mocy czynnej GR również wpływa na straty mocy i energii w sieci, przy czym końcowy efekt, w postaci zmniejszenia lub zwiększenia strat, zależy od mocy źródła i miejsca jego lokalizacji w sieci elektroenergetycznej.
The addition of an active power source (of dispersed generation) to a medium voltage electric power network changes the state of its operation. In the paper, the influence of dispersed generation on the active power loss in distribution network is analyzed. The results show that the changes of active power loss in an electric power network with dispersed generation depend on the source's load and its location within the network.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 43-46
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies