Tytuł:
Effect of Remelting of the Ni-22Cr-9Mo Alloy on its Microstructural and Electrochemical Properties
Autorzy:
Augustyn-Nadzieja, J.
Łukaszczyk, A.
Loch, J.
Powiązania:
https://bibliotekanauki.pl/articles/351218.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ni-Cr-Mo alloys
metal prosthetics restorations
method melted models
artificial saliva solution
corrosion resistance
Opis:
The Ni-Cr-Mo alloys are used as the alternative for the cobalt alloys in the manufacture of metal prosthetic elements, i.e. crowns, bridges and frame prostheses. The article attempts at a materials science characterization of the nickel-based alloy of the commercial name Argeloy N.P Be-Free by Argen. Within the study, examinations were made on the commercial alloy as well as the alloy which was remelted and cast by the los mould (lost wax) method. Observations of the microstructure were performed with the use of optical and electron scanning microscopy. Also, X-ray structural tests were conducted as well as corrosion resistance tests in an artificial saliva solution (pH = 6,7). It was demonstrated that the examined Ni-22Cr-9Mo alloy characterized in a dendritic structure typical of the cast materials. The X-ray qualitative phase analysis revealed the phase γ'(Ni) in both examined materials, as well as the presence of Cr23C6 type carbides and Nb2C, Ta2C (commercial alloy) and NbC, Ta4C0,04 (cast alloy) phases. The effect of the alloy’s remelting and the morphology of the passive layer on the corrosion resistance of the Ni-Cr-Mo alloy was examined. The results of the electrochemical tests show that the process of re-casting only slightly affects the corrosion resistance and the microstructure of the considered alloy. The roles of recasting process and the passive film homogeneity on the corrosion resistance of Ni-Cr-Mo dental alloy were reviewed. The results the electrochemical study show that the dependence of corrosion resistance on the microstructure associated with the recasting process is marginal.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 411-418
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of heat treatment on the microstructure and properties of the corrosion resistance of the prosthetic alloy Wironit ExtraHart (Co-Cr-Mo)
Wpływ obróbki cieplnej na mikrostrukturę i odporność korozyjną protetycznego stopu Wironit ExtraHart (Co-Cr-Mo)
Autorzy:
Augustyn-Nadzieja, J.
Pełka, S.
Loch-Zawrotniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/263988.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Co-Cr-Mo alloys
heat treatment
dendritic microstructure
corrosion resistance
stopy CoCrMo
obróbka cieplna
mikrostruktura dendrytyczna
odporność korozyjna
Opis:
The presented study performs an analysis of the effect of thermal treatment on the microstructure and corrosion resistance of the commercial prosthetic alloy Wironit ExtraHart (Co-Cr-Mo). Experiments of thermal treatment, homogenization, oversaturation as well as oversaturation with ageing of the alloys were carried out. Metallographic tests, hardness measurements, EDS analyses and electrochemical investigations were performed. For the examined samples, the corrosion potential (OCP) and polarization curve (LSV) were determined, based on which the corrosion properties in the simulated solution of artificial saliva were established. The results of the obtained tests made it possible to evaluate the effect of the performed thermal treatment on the changes in the properties (hardness) as well as the microstructure and corrosion resistance of the examined alloy Co-Cr-Mo.
W pracy dokonano analizy wpływu obróbki cieplnej na mikrostrukturę i odporność korozyjną komercyjnego stopu protetycznego Wironit ExtraHart (Co-Cr-Mo). Przeprowadzono eksperyment obróbki cieplnej stopów, wyżarzania ujednorodniającego, przesycania i przesycania ze starzeniem. Wykonano badania metalograficzne, analizę EDS oraz badania elektrochemiczne. Dla badanych próbek wyznaczono potencjał korozyjny (OCP) oraz krzywą polaryzacji (LSV), na podstawie których określono właściwości korozyjne w symulowanym roztworze sztucznej śliny. Wyniki otrzymanych badań pozwoliły stwierdzić wpływ przeprowadzonej obróbki cieplnej na zmiany własności (twardość) i mikrostrukturę oraz odporność korozyjną badanego stopu Co-Cr-Mo.
Źródło:
Metallurgy and Foundry Engineering; 2018, 44, 4; 181-193
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies