Tytuł:
Fault prevention and diagnosis through scada temperature data analysis of an onshore wind farm
Autorzy:
Astolfi, D.
Castellani, F.
Terzi, L.
Powiązania:
https://bibliotekanauki.pl/articles/328436.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
wind energy
wind turbine
SCADA
control system
fault diagnosis
energia wiatru
turbina wiatrowa
system kontroli
diagnoza
błąd
Opis:
Wind turbines, due to the distribution of the source, are an energy conversion system having low density on the territory, whose operational behaviour and production on the short term strongly depends on the stochastic nature of wind. They therefore need accurate assessment prior installation and careful condition monitoring in the operative phase. In the present work, smart post processing of Supervisory Control And Data Acquisition (SCADA) control system data sets is employed for fault prevention and diagnosis through the analysis of the temperatures of the machines. Automatic routines are developed for monitoring the evolution of all the temperature SCADA channels against power production. The methods are tested on an onshore wind farm sited in southern Italy, where nine turbines with 2 MW rated power are installed. The tests are performed both ex post and in real time: it is shown that in the former case, a major mechanical problem is detected, and in the latter case a significant problem to the cooling system is identified before compromising turbine functionality.
Źródło:
Diagnostyka; 2014, 15, 2; 71-78
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of wind turbine misalignment through SCADA data
Autorzy:
Astolfi, D.
Castellani, F.
Scappaticci, L.
Terzi, L.
Powiązania:
https://bibliotekanauki.pl/articles/327708.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
wind energy
wind turbine
SCADA system
fault diagnosis
energia wiatru
turbina wiatrowa
SCADA
system kontroli
diagnostyka uszkodzeń
Opis:
Optimal alignment of wind turbines to the wind direction is a crucial condition for the quality of power output and for the health of the turbines. Actually, bad alignment can cause degraded performances and dangerous loads that can affect, on the long run, the mechanical safety of the wind turbine. Supervisory Control And Data Acquisition (SCADA) systems are becoming widespread in modern wind energy technology because of the appreciable costs – benefits ratio. The common time scale of SCADA, yet, usually is not effective for misalignment diagnosis because the wind varies too rapidly. For this reason, misalignment is often diagnosed using ad hoc techniques as LIDAR-based or spinner anemometers. In the present work, it is shown that very useful indications for the diagnosis of misalignment can be obtained also from the SCADA data, without invoking expensive supplementary control techniques. The method is validated on the data set of a wind farm sited in Italy.
Źródło:
Diagnostyka; 2017, 18, 1; 17-24
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies