Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Silver nanoparticles" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
The effect of hydroxyapatite coating with silver nanoparticles on osseointegration of titanium implants
Autorzy:
Sulej-Chojnacka, Joanna
Woźniak, Waldemar
Andrzejewski, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/1844985.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
implant
hydroxyapatite
Ti6Al4V
silver nanoparticles
Opis:
During the implantation surgery, an infection associated with the biofilm formation may occur. Both the type of the introduced material as well as the implant osseointegration largely determine the effectiveness of bone defect treatment. The materials research is increasingly focusing on improving the osseointegration process. A bacterial biofilm can form on any surface of the artificial organ that has been introduced into the body or surrounding tissues. A bacterial infection is one of the most serious complications of implantology surgery leading to serious physiological damage. As proved in the literature, a solution that can prevent bacterial infections is to modify the implant surface by applying an antibacterial coating, while maintaining the material biocompatibility. The article presents the tests results of prototype implants with hydroxyapatite coatings obtained via plasma spraying on titanium surfaces. The resulting coatings were enriched with silver nanoparticles, the content of which was about 2%. The animal model are New Zealand rabbits. The implants were placed in the femur of the animal. The amount of released ions and the force of pulling the implants from the bone were determined. The binding strength between the joint surface and the implant was determined by the mechanical blocking and biological binding of growing bone tissue. In addition, the surface structure of the obtained implants was evaluated. It has been shown that the surface modification of the implants affected the obtained stabilization value, as compared to the implants surface coated only with hydroxyapatite.
Źródło:
Engineering of Biomaterials; 2020, 23, 154; 9-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of hydroxyapatite coating with silver nanoparticles on osseointegration of titanium implants
Autorzy:
Sulej-Chojnacka, Joanna
Woźniak, Waldemar
Andrzejewski, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/283743.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
implant
hydroxyapatite
Ti6Al4V
silver nanoparticles
Opis:
During the implantation surgery, an infection associated with the biofilm formation may occur. Both the type of the introduced material as well as the implant osseointegration largely determine the effectiveness of bone defect treatment. The materials research is increasingly focusing on improving the osseointegration process. A bacterial biofilm can form on any surface of the artificial organ that has been introduced into the body or surrounding tissues. A bacterial infection is one of the most serious complications of implantology surgery leading to serious physiological damage. As proved in the literature, a solution that can prevent bacterial infections is to modify the implant surface by applying an antibacterial coating, while maintaining the material biocompatibility. The article presents the tests results of prototype implants with hydroxyapatite coatings obtained via plasma spraying on titanium surfaces. The resulting coatings were enriched with silver nanoparticles, the content of which was about 2%. The animal model are New Zealand rabbits. The implants were placed in the femur of the animal. The amount of released ions and the force of pulling the implants from the bone were determined. The binding strength between the joint surface and the implant was determined by the mechanical blocking and biological binding of growing bone tissue. In addition, the surface structure of the obtained implants was evaluated. It has been shown that the surface modification of the implants affected the obtained stabilization value, as compared to the implants surface coated only with hydroxyapatite.
Źródło:
Engineering of Biomaterials; 2020, 23, 154; 9-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies