Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "zero-valent iron" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Desalination of groundwater and impoundments using Nano-Zero Valent Iron, n-Fe°
Autorzy:
Antia, D.D.J.
Powiązania:
https://bibliotekanauki.pl/articles/108538.pdf
Data publikacji:
2015
Wydawca:
Instytut Meteorologii i Gospodarki Wodnej - Państwowy Instytut Badawczy
Tematy:
desalination
zero-valent iron
ZVI
diffusion
saline aquifers
saline impoundments
Opis:
Salinization of groundwater is a major problem, particularly in areas with limited infrastructure. 14 diffusion reactors are operated diabatically at -8°C to 20°C to determine the amount of NaCl removed by n-Fe°. The reactors establish NaCl removal by Fe°: (i) 44,000-77,000 nm particle size (PS) = 0.0675-0.1925 g L-1 [feed water (FW) = 0.89 g L-1]; (ii) 50 nm PS = 0.953-1.14 g L-1 [FW = 1.095-1.19 g L-1]; (iii) 50 nm PS under nitrogen saturation (0.1-0.2 MPa) = 9.693 g L-1 [FW = 10 g L-1]; (iv) <0.01 g 50 nm PS L-1 under nitrogen saturation (0.1-0.2 MPa) = 1.564 g L-1 [FW = 4 g L-1]; (v) 50 nm PS modified by nitrogen saturation (PSN) = 5.52 g L-1 [FW = 6.89 g L-1]. Desalination commences at a time, t, after the n-Fe° is added to the water, and continues with an exponential decline until a base (equilibrium) salinity is reached. The effectiveness of n-Fe° as a desalination agent appears to increase with increased water salinity. Placement of PSN in an existing impoundment, or aquifer, may provide a cost effective, zero energy, partial desalination solution, which can be used to support emergency relief, agriculture and extractive industries.
Źródło:
Meteorology Hydrology and Water Management. Research and Operational Applications; 2015, 3, 1; 21-38
2299-3835
2353-5652
Pojawia się w:
Meteorology Hydrology and Water Management. Research and Operational Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Species formed on iron surface during removal of copper ions from aqueous solutions
Autorzy:
Suponik, T.
Winiarski, A.
Szade, J.
Powiązania:
https://bibliotekanauki.pl/articles/110906.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water
zero-valent iron
copper
X-ray photoelectron spectroscopy
diffraction
Opis:
The subject of the research covered in this paper is the removal of copper (Cu2+) cations from water at low pH (initial values of pH 3 and 6) by means of zero-valent iron. The chemical states and atomic concentrations of solids formed on the surface of zero-valent iron, and the type of deposited polycrystalline substances have been analyzed with the use of XPS and XRD. The type of process causing the copper removal from water at low pH, corresponding to the effect of acid mine drainage, has been identified by analyzing the changes of physicochemical parameters and specified chemicals content in water. Cu2+ was removed from water for the initial pH of 6 was much more effective than at lower pH. The formation of CuxFe3-xO4 , where x≤1, and to a lesser degree Cu2O, Cu0 and/or CuO and/or Cu2S, were the basic processes of the removal of copper at almost neutral pH of water (pH about 6), while the formation of copper in metallic form and Cu2O, as well as probably CuO, were the basic processes for lower pH (pH about 3). The adsorption of Cu2+ on the surface of shell covering square-shaped cold-rolled steel sheet cell was an additional process causing the removal of copper from water at almost neutral pH.
Źródło:
Physicochemical Problems of Mineral Processing; 2015, 51, 2; 731-743
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reactivity of nZVI in the removal of Cu(II) and Zn(II) from synthetic mine drainage
Autorzy:
Suponik, Tomasz
Neculita, Carmen Mihaela
Powiązania:
https://bibliotekanauki.pl/articles/2032928.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
mining industry
nZVI
zero-valent iron
Cu(II)
Zn(II)
przemysł wydobywczy
Opis:
Adsorption properties, including isotherms and kinetics, of nano zero-valent iron (nZVI) for Cu(II) and Zn(II) removal from synthetic mine drainage were evaluated in batch tests. The influence of contact time, nZVI doses, pH, ionic strength, temperature, and concentration on nZVI adsorption properties was assessed. The removal of Cu(II) and Zn(II) increased with pH from 3 to 7 and then stabilized up to pH 10. Moreover, the increased Cu(II) adsorption capacity upon increasing temperature and a positive enthalpy change (ΔH) indicate that the adsorption process is endothermic. The results also showed that the adsorption equilibrium for Cu(II) and Zn(II) was achieved after 50 and 30 min, respectively. Kinetics were best described by a pseudo-nth order model, with the order of sorption of 2.231 and 1.363, and the rate constants of 0.0008 and 0.0679 mg1-n·gn-1/min, for Cu(II) and Zn(II), respectively. The correlation between the amount of metals adsorbed on nZVI surface and the residual amount of metals in water during isothermal tests was best described by the nonlinear Sips model. Using this model, high q maxS were found: 286.6 mg/g and 142.6 mg/g, for Cu(II) and Zn(II), respectively, as indication of their high sorption capacity.
Źródło:
Environment Protection Engineering; 2021, 47, 2; 93-108
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of heavy metals from groundwater affected by acid mine drainage
Autorzy:
Suponik, T.
Blanco, M.
Powiązania:
https://bibliotekanauki.pl/articles/110087.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
coal mine waste dumps
acid mine drainage
groundwater
PRB technology
metals
zero-valent iron
Opis:
Batch tests have been used to assess the level of the removal of metals (copper, nickel, cobalt, zinc, and chromium, in cationic and in anionic forms) from water at low pH values affected by acid mine drainage. The predominant processes which result in the removal with the use of zero-valent iron (Fe0) in Permeable Reactive Barrier Technology were evaluated. The most probable processes for each metal have been presented in drawings. There are: reductive precipitation leading to the metallic form, co-precipitation mainly with iron in the form of oxides and/or hydroxides and adsorption on the surface of iron corrosion products or on the surface of zero-valent iron.
Źródło:
Physicochemical Problems of Mineral Processing; 2014, 50, 1; 359-372
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Spontaneous Oxidation Processes of Zero-valent Iron and Electrocoagulation for Reactive Black 5 Removal
Zastosowanie procesów samorzutnego utleniania żelaza na zerowym stopniu utlenienia (ZVI) oraz elektrokoagulacji (EC) w usuwaniu Reactive Black 5
Autorzy:
Wysocka, I.
Filipkowska, U.
Jóźwiak, T.
Powiązania:
https://bibliotekanauki.pl/articles/233177.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
dye removal
zero-valent iron
electrocoagulation
reactive dyes
usuwanie barwników
utlenianie żelaza
elektrokoagulacja
barwniki reaktywne
Opis:
Two methods of Reactive Black 5 dye removal were compared in this work, namely electrocoagulation (EC) and one based on spontaneous electrochemical oxidation of zero-valent iron (ZVI). Both methods are based on electrode processes and the sorption process and allow to achieve a similar effectiveness of dye removal. In the case of ZVI, however, a longer contact time or a greater surface area of the electrodes applied is necessary. In turn, the ZVI enables to conduct the processes of dye removal with no requirement for an external source of electric current (lower exploitation inputs). The study demonstrated that the application of both the ZVI method and EC is especially advisable in the case of lower initial concentrations of dye in the solution, i.e. the higher the concentration, the lower the contribution of electrode processes in dye removal from the solution and the greater the contribution of sorption processes.
W ramach niniejszej pracy porównano dwie metody usuwania barwnika Reactive Black 5. Metodę elektrokoagulacji (EC), oraz metodę opartą na samorzutnym elektrochemicznym utlenianiu żelaza na 0 stopniu utlenienia (ZVI). Obie metody wykorzystują procesy elektrodowe oraz procesy sorpcji, umożliwiając uzyskanie podobnej efektywność usuwania barwnika. W przypadku ZVI wymagany jest jednak dłuższy czas kontaktu, lub większa powierzchnia zastosowanych elektrod. ZVI umożliwia jednak przeprowadzenie procesów usuwania barwy, bez konieczności stosowania zewnętrznego źródła prądu (mniejsze nakłady eksploatacyjne). Badania wykazały, że zastosowanie zarówno metody ZVI i EC ma szczególne uzasadnienie w przypadku niższych stężeń początkowych barwnika w roztworze. Im wyższe stężenie, tym udział procesów elektrodowych w usuwaniu barwy roztworu jest mniejszy a przewagę zyskują procesy sorpcji.
Źródło:
Fibres & Textiles in Eastern Europe; 2017, 4 (124); 121-128
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automotive fleet repair facility wastewater treatment using air/ZVI and air/ZVI/H2O2 processes
Oczyszczanie ścieków z zakładów naprawczych floty samochodowej z wykorzystaniem procesów powietrze/ZVI i powietrze/ZVI/H2O2
Autorzy:
Bogacki, J. P.
Al-Hazmi, H.
Powiązania:
https://bibliotekanauki.pl/articles/205311.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment
zero-valent iron
advanced oxidation processes
AOP
ZVI
oczyszczanie ścieków
żelazo metaliczne
zaawansowane procesy utleniania
Opis:
Advanced automotive fleet repair facility wastewater treatment was investigated with Zero-Valent Iron/Hydrogen Peroxide (Air/ZVI/H2O2) process for different process parameters: ZVI and H2O2 doses, time, pH. The highest Chemical Oxygen Demand (COD) removal efficiency, 76%, was achieved for ZVI/H2O2 doses 4000/1900 mg/L, 120 min process time, pH 3.0. COD decreased from 933 to 227 mg/L. In optimal process conditions odor and color were also completely removed. COD removal efficiency was increasing with ZVI dose. Change pH value below and over 3.0 causes a rapid decrease in the treatment effectiveness. The Air/ZVI/H2O2 process kinetics can be described as d[COD]/dt = -a [COD]tm, where ‘t’ corresponds with time and ‘a’ and ‘m’ are constants that depend on the initial reagent concentrations. H2O2 influence on process effect was assessed. COD removal could be up to 40% (560 mg/L) for Air/ZVI process. The FeCl3 coagulation effect was also evaluated. The best coagulation results were obtained for 700 mg/L Fe3+ dose, that was slightly higher than dissolved Fe used in ZVI/H2O2 process. COD was decreased to 509 mg/L.
Ścieki z zakładu naprawczego floty samochodowej poddano oczyszczaniu z wykorzystaniem żelaza metalicznego i nadtlenku wodoru (Air/ZVI/H2O2). Badano wpływ dawki żelaza i nadtlenku wodoru, czasu i pH na efektywność procesu. Największy stopień usunięcia ChZT, 76%, uzyskano dla dawek ZVI/H2O2 4000/1900 mg/L, czasu 120 min i pH 3.0. ChZT zmniejszono z 933 do 227 mg/L. Dodatkowo uzyskano całkowite usunięcie barwy i zapachu. Skuteczność usunięcia ChZT rosła wraz ze wzrostem zastosowanej dawki ZVI. Zmiana pH na inne niż 3, powoduje gwałtowne zmniejszenie efektywności procesu. Kinetyka procesu może zostać opisana z wykorzystaniem równania d[COD]/dt = -a [COD]tm, gdzie ‘t’ oznacza czas a ‘a’ i ‘m’ są stałymi zależnymi od początkowego stężenia reagentów. Badano także wpływ H2O2 na efektywność procesu. Skuteczność usunięcia ChZT wynosi 40% (560 mg/L) w przypadku zastosowania ZVI bez dodatku H2O2. Określono także skuteczność koagulacji z wykorzystaniem FeCl3. Najlepsze rezultaty uzyskano dla dawki Fe3+ 700 mg/L, zmniejszając ChZT do 509 mg/L.
Źródło:
Archives of Environmental Protection; 2017, 43, 3; 24-31
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic-assisted synthesis of reactive carboxymethyl cellulose stabilized nano zero-valent iron and its application for removal of Cr6+ and Cu2+ ions
Autorzy:
Ayob, A.
Santiagoo, R.
Amneera, W. A.
Ismail, N.
Abdullah, A. Z.
Powiązania:
https://bibliotekanauki.pl/articles/207403.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
high resolution transmission
electron microscopy
light scattering
transmission electron microscopy X ray diffraction
zero-valent iron
wysoka rozdzielczość transmisyjna
mikroskopia elektronowa
dyfrakcja rentgenowska
żelazo
Opis:
Carboxymethyl cellulose (CMC) was used in the chemical reduction using sodium borohydride to yield dispersive nano zero-valent iron (nZVI) particles as reactive and stable adsorbents. CMC- -stabilized nZVI particles were characterized via UV-visible light spectroscopy, X-ray diffraction, dynamic light scattering, transmission electron microscopy, and specific surface area assisted using a probe ultrasonication dispersing tool at 50% amplitude power. High catalytic reactivity obtained in pseudo-first order reaction for Cr6+ (rate constant K1 = 0.0311 min–1) and pseudo-second order for Cu2+ (rate constant K2 = 0.0946 g·mg–1·min–1) indicated that colloidal stability of nZVI particles can be achieved with a stabilizer for the removal of toxic contaminants.
Źródło:
Environment Protection Engineering; 2016, 42, 2; 55-79
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of Azo Dye Acid Red 27 from Aqueous Solutions Using Classical and Modified Fenton Reagent with Zero-Valent Iron
Usuwanie barwnika azowego czerwień kwasowa 27 z roztworów wodnych przy zastosowaniu odczynnika Fentona modyfikowanego żelazem zero wartościowym
Autorzy:
Kliś, Simona
Thomas, Maciej
Barbusiński, Krzysztof
Gołombek, Klaudiusz
Krzemiński, Łukasz
Chyc, Marek
Powiązania:
https://bibliotekanauki.pl/articles/234298.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
Acid Red 27
Fenton reagent
modified Fenton reagent
zero-valent iron
wastewater treatment
czerwień kwasowa 27
odczynnik Fentona
zmodyfikowany odczynnik Fentona
żelazo o zerowej wartościowości
oczyszczanie ścieków
Opis:
The article compares the classic Fenton reagent (Fe2+/H2O2) with its modification with zero-valent iron (ZVI/ H2O2) to remove azo dye Acid Red 27 from aqueous solutions at a concentration of 100 mg/L. For both methods, the most favorable parameter values were determined at which visual discoloration of the solutions tested was obtained (for Fe2+/ H2O2:pH 3.5, H2O2=60 mg/L, Fe2+/ H2O2=0.3, t=15 min, and for ZVI/ H2O2pH = 3, H2O2=40 mg/L, ZVI=80 mg/L, t=15 min). Under these conditions, the COD value was reduced by 71.5% and 69.2% for the classic Fenton and its modification, respectively. A reduction in toxicity was also obtained for Vibrio fischeri bacteria to below 25% by using the Microtox test. ZVI digestion at acidic pH for 10 minutes allowed to shorten the reaction time by about four times - from 15 to 4 minutes. BET analysis showed that the specific surface area increases with the digestion time, which significantly accelerates the reaction. The visual discoloration of aqueous solutions was obtained, and the final COD values were very small, ranging from 49-53 mg O2/L. According to the Aliivibrio fischeri toxicity classification test for water samples, all solutions of dyes tested can be considered as non-toxic (toxicity value <25%). In the study presented, results of decreasing the COD value and concentration of the dye in the ZVI/ H2O2 method obtained are slightly worse compared to the Fe2+/ H2O2method. However, taking the decolorisation time as a criterion, a four times faster decolorisation time was obtained in the ZVI/ H2O2 method, compared to the Fe2+/ H2O2 method.
W artykule porównano klasyczny odczynnik Fentona (Fe2+/H2O2) z jego modyfikacją żelazem o zerowej wartościowości (ZVI/ H2O2), w celu usunięcia barwnika azowego czerwień kwasowa 27 z wodnych roztworów, o stężeniu 100 mg/L. Dla obu metod wyznaczono najkorzystniejsze wartości parametrów, przy których uzyskano wizualne odbarwienie badanych roztworów (dla (Fe2+/H2O2): pH 3,5, H2O2=60 mg/L, Fe2+/ H2O2=0,3, t=15 min. i dla ZVI/H2O2: pH 3, H2O2=40 mg/L, ZVI=80 mg/L, t=15 min. W tych warunkach wartość ChZT spadła o 71,5% i 69,2% dla klasycznego Fentona i jego modyfikacji. Zmniejszenie toksyczności uzyskano również dla bakterii Aliivibrio fischeri (poniżej 25%) przy zastosowaniu testu Microtox. Trawienie ZVI w kwasowym pH przez 10 minut pozwoliło skrócić czas reakcji około cztery razy z 15 do 4 minut. Analiza BET wykazała, że powierzchnia właściwa wzrasta wraz z czasem trawienia, co znacznie przyspiesza reakcję. Uzyskano wizualne odbarwienie roztworów wodnych, a końcowe wartości ChZT były bardzo małe i mieściły się w zakresie 49-53 mg O2/L. Zgodnie z testem klasyfikacji toksyczności wobec Vibrio fischeri dla próbek wodnych, wszystkie testowane roztwory barwników można uznać za nietoksyczne (wartość toksyczności <25%).
Źródło:
Fibres & Textiles in Eastern Europe; 2019, 5 (137); 100-106
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka właściwości mechanicznych wybranych materiałów reaktywnych
The mechanical properties of selected reactive materials
Autorzy:
Pawluk, K.
Powiązania:
https://bibliotekanauki.pl/articles/40807.pdf
Data publikacji:
2015
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
materialy reaktywne
wlasciwosci fizyczne
wlasciwosci mechaniczne
badania laboratoryjne
zelazo zerowartosciowe
zeolity
sciskanie jednoosiowe
wytrzymalosc na scinanie
scisliwosc
reactive material
physical property
mechanical property
laboratory research
zero-valent iron
zeolite
uniaxial test
compression strength
compressibility
Opis:
W artykule przedstawiono wyniki badań właściwości fizycznych i mechanicznych materiałów reaktywnych. Materiały reaktywne powszechnie wykorzystywane są do budowy strefy oczyszczania przepuszczalnych barier reaktywnych, służących do oczyszczania środowiska gruntowo-wodnego z zanieczyszczeń. Dotychczasowe kryterium doboru materiałów reaktywnych do budowy barier obejmowało jedynie właściwości zatrzymania zanieczyszczeń oraz badania filtracyjne. Z uwagi na aspekt inżynierski projektowanych konstrukcji w środowisku gruntowo-wodnym i ich długi czas pracy proponuje się uwzględnić również właściwości fizyczne i mechaniczne tych materiałów. W pracy przedstawiono wyniki badań właściwości wytrzymałościowych i odkształceniowych wybranych materiałów reaktywnych, które mogą zostać wykorzystane przy doborze technologii wykonania oraz sprawdzenia stanów granicznych nośności podczas etapu projektowania PBR.
In this paper the physical and mechanical properties of reactive materials are presented. Reactive materials are build the reactive zone of permeable reactive barrier (PRB) used for the remediation of contaminated groundwater. Up till now the criteria for selecting a reactive material for PRB are included only the remediation and hydraulic properties of materials. However, physical and mechanical properties of these materials have to be taking into account due to the engineering aspect of design parameters of PRB in groundwater, as well as their stability and longevity. The paper presents the results of shear strength and compressibility properties of selected reactive materials that may be considered during the selection of construction technology of barrier and to verify the ultimate limit states during the design stage of PBR.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2015, 14, 3
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies