Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cementowanie" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Receptura zaczynu lekkiego do uszczelniania otworów w strefie niskich ciśnień złożowych
Formula of lightweight cement slurry for sealing boreholes in the low reservoir pressure zone
Autorzy:
Kremieniewski, Marcin
Pikłowska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1834111.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
zaczyn cementowy
zaczyn lekki
cementowanie otworów wiertniczych
frakcjonowanie
sedymentacja
anizotropia
cement slurry
lightweight slurry
well cementing
fractionation
sedimentation
anisotropy
Opis:
In the technology of sealing casing columns in a borehole, sometimes it is necessary to use cement slurry with reduced density. This occurs most often during sealing of the borehole in the low reservoir pressure zone. To design lightweight cement slurry, an addition of filler material is used, the density of which is much lower than the density of cement. However, the presence of such an additive in the structure of fresh cement slurry may sometimes cause destabilization of the system manifested by excessive fractionation, as a result of which light particles migrate to the upper parts of the cement slurry and heavy cement grains sink to the bottom. In addition, cement slurries containing light additives also show reduced values of mechanical parameters, greater porosity and capacity for gas migration, which may disqualify a given cement slurry for use in borehole conditions. In order to eliminate these adverse changes occurring in the structure of both fresh and hardened lightweight cement slurry, admixtures are used to significantly improve the technological parameters of the designed recipe. Appropriate selection, both quantitative and qualitative, of selected agents makes it possible to eliminate the cement slurry fractionation, as a result of which it is possible to obtain a homogeneous structure of the fresh cement slurry, and the cement sheath formed after setting will demonstrate the isotropic properties of the tested mechanical parameters. In addition, additives and low molecular weight admixtures allow sealing of the cement sheath matrix in such a way that the compressive strength is significantly improved and the value of permeability and porosity is reduced. The article discusses the results of research on the development of lightweight cement slurry recipes intended for scaling of openings in the zone of low reservoir pressures. As a control sample, a recipe was selected that had been used in well conditions. This cement slurry was selected for modification due to the lack of sedimentation stability. The following recipes contained various amounts of filling materials. As light additives, filter perlite, aluminosilicate microsphere and glass microsphere were used. However, two forms of silica were used to improve sedimentation stability and obtain appropriate mechanical parameters: a colloidal sodium silicate solution and hydrophilic nanosilica. The designed cement slurry recipes were characterized by appropriate technological parameters and sedimentation stability. The modifications introduced to the cement slurries allowed to achieve a homogeneous microstructure of the hardened cement slurry and an increase in the value of mechanical parameters was obtained. The developed group of recipes can be used to seal openings in the low reservoir pressure zone at a temperature of about 30°C and a pressure of about 3 MPa.
Źródło:
Nafta-Gaz; 2020, 76, 9; 577-584
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Receptury zaczynów do uszczelniania kolumn rur posadowionych w otworach wierconych w skałach chłonnych
Recipes of cement slurries for sealing pipe columns in boreholes drilled in absorptive rocks
Autorzy:
Kremieniewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1835080.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
zaczyn cementowy
zaczyn lekki
otwór wiertniczy
cementowanie otworów wiertniczych
skały chłonne
ucieczki cementu
cement slurry
lightweight slurry
borehole
well cementing
absorptive rocks
cement escapes
Opis:
Uszczelnienie kolumny rur okładzinowych w otworach wierconych w rejonie występowania skał chłonnych może przysporzyć wielu problemów. Głównym utrudnieniem jest możliwość ewentualnej ucieczki cementu w strefę chłonną i w konsekwencji zanik cementu i utrata cyrkulacji, efektem czego będzie brak uszczelnienia danego interwału. W celu ograniczenia tego niekorzystnego zjawiska ucieczki cementu w strefy chłonne opracowywane są receptury zaczynów o obniżonej gęstości. Tego rodzaju zaczyny lekkie pozwalają na znaczne obniżenie ciśnienia hydrostatycznego w wypełnianej przestrzeni pierścieniowej otworu, dzięki czemu zachowana zostaje równowaga w układzie ciśnienie złożowe–ciśnienie hydrostatyczne. Podczas projektowania receptury zaczynu lekkiego stosuje się domieszki lekkie, których obecność w recepturze zaczynu powoduje obniżenie jego gęstości. Wprowadzenie takich lekkich frakcji może jednak niekiedy skutkować znacznym sedymentowaniem płynnego zaczynu i wzrostem jego parametrów reologicznych. Jest to niekorzystne, ponieważ zaczyn taki będzie wówczas wymagał zastosowania wyższych wydatków tłoczenia, co może skutkować wzrostem oporów hydraulicznych i niepożądanym wniknięciem cementu w strefy chłonne. Ponadto płaszcz cementowy powstały z zaczynów lekkich charakteryzuje się gorszymi wartościami parametrów mechanicznych i strukturalnych. W celu wyeliminowania tych niekorzystnych czynników, receptura zaczynu cementowego musi być opracowywana w taki sposób, aby jej parametry odpowiadały konkretnym warunkom otworowym, co zostało omówione w niniejszej publikacji. Problematyka dotycząca receptur zaczynów przeznaczonych do uszczelniania kolumn rur posadowionych w otworach wierconych w skałach chłonnych jest ciągle aktualna i wymaga prowadzenia badań nad nowymi zagadnieniami. Dlatego też w niniejszym artykule przedstawione zostały wyniki prac badawczych nad opracowaniem nowych zaczynów przeznaczonych do uszczelniania kolumn rur okładzinowych posadowionych w tego rodzaju formacjach geologicznych. Opracowano cztery receptury zaczynów, których parametry porównywano do receptury kontrolnej. Do sporządzania zaczynów użyto zarówno stosowane dotychczas, jak również nowe lekkie dodatki wypełniające i środki pozwalające na uzyskanie homogenicznej struktury. Zaprojektowano nowe receptury zaczynów dla warunków otworowych o temperaturze około 50°C i ciśnieniu około 10 MPa. Przeprowadzono badania stabilności sedymentacyjnej zaczynów oraz badania parametrów decydujących o efektywności uszczelniania. Dla próbek stwardniałych zaczynów wykonano badania porowatości i na podstawie uzyskanych wyników określono jednorodność struktury tworzącego się płaszcza cementowego.
Sealing the casing pipe column in holes drilled in the area of absorptive rocks can cause many problems. The main difficulty is the possible escape of cement in the absorption zone and, consequently, the disappearance of cement and loss of circulation, the effect of which will be the lack of sealing the given interval. In order to reduce this phenomenon of the escape of cement into absorptive zones, the recipes of slurries with reduced density are developed. Such lightweight slurries allow to reduce the hydrostatic pressure in the space of the annular opening, thanks to which the balance in the system of the reservoir pressure – hydrostatic pressure is preserved. When designing lightweight cement slurry, light admixtures are used that reduce density. However, the introduction of such light fractions can sometimes result in a strong sedimentation of the liquid slurry and an increase in its rheological parameters. This is disadvantageous, because the slurry will then require the use of expensive pressing, which can cause an increase in hydraulic resistance and penetration of cement into the absorptive zones. In addition, the cement coat made of lightweight slurries is characterized by poorer values of mechanical and structural parameters. In order to eliminate these unfavorable factors, the cement slurry must be developed so that its parameters correspond to the specific borehole conditions, as discussed in this publication. Problems concerning the recipes of cement slurries for sealing the columns of pipes set in holes drilled in absorptive rocks are still valid and require research on new issues. Therefore, the article presents the results of research works on the development of new cement slurries intended for sealing the columns of casing pipes placed in such geological formations. Four leaven formulas were developed, whose parameters were compared to the control recipe. Previously used and new lightweight filler additives and the means to obtain a homogeneous structure were used to prepare the leaven. New recipes for cement slurries were designed for borehole conditions with a temperature of approx. 50°C and a pressure of approx. 10 MPa. Sedimentation stability tests of cement slurries and testing of parameters determining the effectiveness of sealing were carried out. The porosity tests were carried out for samples of hardened slurries and the homogeneity of the structure of the cement coat formed was determined based on the obtained results.
Źródło:
Nafta-Gaz; 2019, 75, 8; 451-457
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zaczyny do uszczelniania otworów w warunkach niskich wartości gradientów ciśnienia szczelinowania skał oraz do prac rekonstrukcyjnych
Cement slurries for sealing boreholes in conditions of low pressure gradients of rock fracturing and for workover jobs or operations
Autorzy:
Kremieniewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1834238.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
zaczyn cementowy
zaczyn lekki
cementowanie otworów wiertniczych
niski gradient szczelinowania
prace rekonstrukcyjne
cement slurry
lightweight slurry
well cementing
low fracturing gradient
workover jobs or operations
Opis:
The slurries most commonly used in the conditions of occurrence of low values of fracturing pressure gradients, in the area of weak, porous rocks, or during bore workover operations are reduced density recipes. The use of lightweight slurries containing fractions with dimensions larger than the diameter of cement grains allows to eliminate the possibility of seeping of sealing liquid through the rock struc- ture with significant absorbency. Due to the low value of hydrostatic pressure properly selected, lightweight slurry doesn’t cause fracturing of the structure of weak rocks. However, despite the numerous advantages of lightweight slurry, there are also negative aspects, which may include first of all excessive fractionation. This cement slurry behavior is disadvantageous because it causes the formation of a heterogeneous structure of the cement sheath after setting. Therefore, the main parameter that should be given the most attention when designing a lightweight cement slurry recipe is the sedimentation stability. In order to eliminate excessive fractionation, means that allow particles of different densities to be maintained in the entire volume of the liquid are used. Appropriate qualitative and quantitative selection of individual additives allows to obtain cement slurry with optimal properties, adapted to specific geological and technical conditions, which will not sediment. The resulting cement sheath will have comparable values of tested parameters regardless of the place of measurement. Issues regarding reduced density slurry recipes intended for sealing boreholes under low fracture pressure gradients and for workover operations require continuous improvement and research. Therefore, this publication discusses the results of research work on the development of new cement slurries for sealing holes under conditions mentioned above. Four low density cement slurry recipes were designed, whose parameters were compared with the control recipe. During the implementation of research works, both previously used as well as new lightweight fillers and measures to limit excessive fractionation of designed recipes were used. New slurry recipes have been developed for well conditions with a temperature of about 30°C and a pressure of about 5 MPa. Slurry fractionation were tested and parameters determining the sealing efficiency were studied. In the case of samples of hardened cement slurries, compressive strength tests were performed and the bonding strength (adhesion) of the hardened cement slurry with the surface of the casing pipe was determined.
Źródło:
Nafta-Gaz; 2020, 76, 2; 102-109
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korelacja wyników badań wytrzymałości na ściskanie i przyczepności do rur stalowych płaszcza cementowego z zaczynu o obniżonej gęstości
Correlation of cement sheath mixed of lightweight slurry compression strength and adhesion to steel pipes tests results
Autorzy:
Kremieniewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1834961.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
wytrzymałość na ściskanie
przyczepność do rur stalowych
płaszcz cementowy
cementowanie otworów
korelacja
zaczyn o obniżonej gęstości
zaczyn lekki
compressive strength
cement bond
cement sheath
well cementing
correlation
lightweight cement slurry
Opis:
Podczas projektowania receptury zaczynu cementowego jednym z najczęściej określanych parametrów po związaniu zaczynu jest jego wytrzymałość na ściskanie. Parametr ten może być badany za pomocą metody niszczącej w hydraulicznej prasie wytrzymałościowej, jednak w ostatnich latach coraz częściej wytrzymałość mechaniczną wyznacza się przy użyciu metody nieniszczącej – poprzez pomiar prędkości przenikania fali w ultradźwiękowym analizatorze cementu. Ze względu na to, że jest to badanie proste do przeprowadzenia, ponieważ urządzenie automatycznie rejestruje przyrost wytrzymałości mechanicznej w jednostce czasu, to badanie takie najczęściej wykonuje się w ośrodkach badawczych, a wyniki są umieszczane w wytycznych do cementowania. Należy jednak zaznaczyć, że pod względem poprawy efektywności uszczelniania i stabilizacji kolumn rur okładzinowych bardziej istotna jest przyczepność tworzącego się płaszcza cementowego do powierzchni rur okładzinowych i formacji skalnej. Jednak tego rodzaju wyniki badań najczęściej są zaniedbywane. Ze względu na zależność pomiędzy wartością wytrzymałości mechanicznej i przyczepności stwardniałego zaczynu do powierzchni rur stalowych występuje możliwość obliczenia z dużym prawdopodobieństwem wartości przyczepności na podstawie uzyskanych wyników wytrzymałości na ściskanie stwardniałego zaczynu. Istnieją publikacje poruszające tematykę zależności analizowanych cech, jednak nie natrafiono na wyniki analizy korelacyjnej, na podstawie czego można by było określić, w jakim stopniu porównywane parametry mogą się pokrywać, a szczególnie w przypadku próbek z zaczynów o obniżonej gęstości. W związku z powyższym w niniejszej publikacji omówione zostały wyniki badań, na podstawie których przeprowadzono analizę korelacyjną wartości wytrzymałości na ściskanie i przyczepności do rur stalowych płaszcza cementowego powstałego z zaczynu o obniżonej gęstości. Analiza korelacyjna została wykonana dla wyników badań wartości wytrzymałości na ściskanie i przyczepności do rur stalowych próbek powstałych z 9 receptur zaczynów lekkich. Zaczyny podzielono na 3 grupy w zależności od rodzaju dodatku obniżającego gęstość. Dodatkową zmienną była temperatura i ciśnienie hydratacji. Dla tak sporządzonych próbek stwardniałych zaczynów wykonane zostały badania wytrzymałości na ściskanie oraz badanie przyczepności stwardniałego zaczynu do rury stalowej po czasie hydratacji wynoszącym 2, 7, 14 oraz 28 dni. Następnie uzyskane wyniki zostały poddane analizie korela- cyjnej, na podstawie której określono relacje pomiędzy analizowanymi cechami. Korelowano zależność przyczepności do rur od wartości wytrzymałości dla dwóch grup analizowanych cech. W pierwszej grupie analizie poddano stały skład zaczynu w zmieniającej się temperaturze pomiaru, natomiast w drugiej grupie analizowano różne receptury zaczynów w tej samej temperaturze. Na podstawie uzyskanych wyników wykreślono równania empiryczne. Obliczono również, jaki procentowy udział w wartości wytrzymałości na ściskanie stanowi wartość przyczepności do rur stalowych. Uzyskane wyniki mogą być pomocne przy określaniu wartości przyczepności płaszcza cementowego z zaczynu lekkiego do rur stalowych w przypadku posiadania tylko wartości wytrzymałości na ściskanie.
When designing the cement slurry recipe, one of the most commonly deter-mined parameters after setting the slurry is its compressive strength. This parameter can be tested by a destructive method using a hydraulic testing machine. In recent years, however, mechanical strength has increasingly been determined using a non-destructive method by measuring the speed of wave penetration in the Ultrasonic Cement Analyzer. As this test is simple to perform because the device automatically records the increase in mechanical strength per unit of time, it is most often carried out in research centers, and the results are included in the cementing guidelines. It should be noted that in terms of improving the efficiency of sealing and stabilization of the casing pipe columns, the adhesion of the cement sheath to the surface of the casing and rock formation is more important. However, these types of test results are mostly neglected. Due to the relationship between the value of mechanical strength and adhesion of the hardened cement slurry to the surface of steel pipes, it is possible to calculate the adhesion value with high probability based on the obtained compressive strength of the hardened cement slurry. There are publications on the dependencies of the analyzed features, but no correlation analysis results based on which it would be possible to determine to what extent the compared parameters can overlap were found, especially in the case of lightweight cement slurries. This publication therefore discusses the results of the research on the basis of which a correlation analysis of the values of compressive strength and adhesion to steel pipes of the cement sheath produced from reduced density cement slurry was carried out. The said analysis was carried out for the results of the tests of compressive strength and adhesion values for steel pipes of samples made from 9 lightweight cement slurries recipes. The cement slurries were divided into 3 groups depending on the type of density-reducing additive. An additional variable was the temperature and hydration pressure. For such prepared samples of hardened cement slurries, compressive strength tests and adhesion tests of hardened slurry to steel pipe after hydration time of 2, 7, 14 and 28 days were performed. The obtained results were then subjected to a correlation analysis on the basis of which the relations between the analyzed features were determined. The dependence of adhesion to pipes depending on the strength value for two groups of analyzed features was correlated. In the first group, a constant composition of cement slurries with changing temperature of the measurement was analyzed, while in the second group, various recipes of cement slurries were analyzed at the same temperature. On the basis of the obtained results, empirical equations were plotted. It was also calculated what percentage share of the value of compressive strength constitutes the value of adhesion to steel pipes. The results obtained can be helpful in determining the adhesion value of the cement sheath made of lightweight slurry to steel pipes when only compressive strength values are available.
Źródło:
Nafta-Gaz; 2019, 75, 10; 613-624
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies